{{id}} {{{paragraph}}}
DatasheetUltrasonic Sensor with TEACH-Mode Configuration 1, 2 and 3 m ( , , and ft) versions with short dead zones(10% of max range) Built-in temperature compensation Fast, easy-to-use TEACH-Mode programming; no potentiometeradjustments Configure with either a positive or negative analog output slope Remote TEACH for security and convenience Wide operating temperature range of 40 to +70 C ( 40 to +158 F) Choose either 0 to 10V dc or 4 to 20 mA output model Compact, self-contained, right-angle Sensor package with fullyencapsulated electronicsModelsModelsRange and FrequencyCable1 Supply VoltageAnalog OutputResponse TimeT30 UXUA100 mm to 1 m ( in to 39 in)224 kHzStandard 2 m( ft) cable10 to 30 V dc0 to 10 V dc45 ms or 105 ms selectableT30 UXIA4 to 20 mAT30 UXUB200 mm to 2 m ( in to 78 in)174 kHz0 to 10 V dc92 ms or 222 ms selectableT30 UXIB4 to 20 mAT30 UXUC300 mm to 3 m ( in to 118 in)
3 Sensor will not Teach or indicate “Teach Not Accepted” when there is no signal present (Signal LED Red or Flashing Red) U-GAGE ® T30UX Series with Analog Output 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 141958 Rev. E