DuraForce HPV Variable Pumps for Closed Loop Operation2 eaton HPV Variable Pumps for Closed Loop Operation E-PUPI-MC009-E5 September 2014 Table of Contents ContentsThe Closed loop 4 General technical data 5 Model codes 6 Operational parameters Life time recommendations 9 Filtration and Filters 9 Pressure fluids 10 Mounting Orientation 10 Torque transmission 11 Mounting flange 12 Drive shaft, Excess length 13 PTO flange 14 Output shaft 14 Gear Pumps 15 External gear pump EGP 15 Internal gear pump IGP 16 PTO flange with IGP 17 Controls 18 Control accuracy 19 Mechanical-hydraulic - M 20 Hydraulic - H 22 Hydraulic-mechanical - CA 24 Electro-hydraulic - E1 and E5 25 Electro-hydraulic - E2 26 Electro-hydraulic - E 27 Dimensions M-controls 29 H-controls 30 CA-controls 31 E-controls 32 Modular system 33 Tandem Pumps 36 Multiple Pumps 37 Modular system features 38 The data on which this brochure is based correspo
EATON HPV – Variable Pumps for Closed Loop Operation E-PUPI-MC009-E5 September 2014 5 General Technical Data The table shows the complete capacity range of the pumps, while the diagram below shows the recommend-ed practical range for the different nominal sizes of the HPV pump with control limit between 200 bar ∆pmin and