Flow compensator pressure exceeds 15 bar [210 PSI].Use a gauge that is dampened or glycerine filled. Withthe gauge installed and the load sensing valve in theclosed position, start the systemand observe the flowcompensator pressure. If thereading is other than 13 to 15bar [190 to 210 PSI],readjustment of the flowcompensator may be ) To change setting, remove the adjustment screw coverfrom the flow compensator valve. Loosen the flowcompensator adjustment screw lock nut with a 7/16 inchopen end ) With the system running andsystem control valve in theclosed position, use a 1/8 inchAllen wrench to turn theadjustment screw to the properor desired flow compensatedpressure. Clockwise rotation of the adjustment screw willincrease the pressure setting and counter-clockwiserotation will decrease the pressure setting.
To check or readjust pressure compensator valve setting: 7) Install pressure gauge into gauge port use a 1/2 inch open end wrench and remove the plug furthest