Transcription of IP69k tightness test - Concens
{{id}} {{{paragraph}}}
IP69k tightness test Concens A/S resundvej 7 6715 Esbjerg Att: Henning Frank Subject: IP69k dust and water test. Sample: Actuator No: Con35 - 0809 and Con50 - 0809 Applied method: The IP6X dust test has been carried out in accordance with the international standard IEC 60529 Edition 2001-02. A connection M5 for the vacuum hose has been made in the bottom part of the actuator types. A vacuum of 20mbar has been supplied to the actuators during the made M5 threaded connection for a period of 2 hours. The IPX9k water test has been carried out in accordance with the DIN Standard VDE 40050 part 9. from May 1993. The water test see clause and clause 8, and table 4 and 8. The water pressure has been adjusted to 85 bar. The water temperature has been about 80 C. Equipment used: Dust test IP6X vacuum gauge ID No: 87837 IPX9k water pressure gauge ID No: 86309 IPX9k water temperature measuring Testo 925 ID No: 88309 Insulation resistance tester Norma Unilap ID No: 59190 Performed by: Andreas Andersen - L7-S14 - Phone: +45 74884242 Date: 15-09-2008 Page: 1 of 4 Report No.
2008-2657-IP69k Results from the IP69k test. Before and after the IP69k test the following tests has been carried out: Actuator type Con 35:
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
IP69K explanation, IP69k, IP69K test, Test, Temposonics, Hydraulic Screw-in Cartridge Valves SiCV, Eaton, Eaton Hydraulic Screw-in Cartridge Valves SiCV, 550824K MH Series MH Analog Data Sheet0613, POLAMCO HIGH POWER CONNECTORS, POLAMCO HIGH POWER . CONNECTORS, Automation Fair® Event New Products, Automation Fair® Event New Products and Solutions Directory