1 Dongguan ORTUR Intelligent Technologies Co., Ltd. 56 Maxin Road, Changping Town, Dongguan 523565, Guangdong Province, China ORTUR ORTUR grounding Guide10 February 2021 ORTUR LASER MASTER 22 Dongguan ORTUR Intelligent Technologies Co., Ltd. 56 Maxin Road, Changping Town, Dongguan 523565, Guangdong Province, ChinaOrtur LASER MASTER 2 grounding AdvisoryRelease Date: 10-02-2021 ORTUR Action Advice: RecommendedSome users have been reporting and experiencing Static Electricity build up in their machines while in use, especially on raster engraving build up of Static Electricity can become severe to the point that its discharge - via the 12v rail - can cause the motherboard to reset.
resistance to discharge, and in the case of the Ortur Laser Master 2, this path is through the Motherboard and the 12v rail. ... For the simplified methods of grounding, this is the final step on the wiring harness preparation. 8 Dongguan Ortur Intelligent Technologies Co., Ltd.