Practice Note for Authorized Persons, Registered ...
swimming pool and multi-purpose ball court) are very space consuming when these facilities are provided a more relaxed percentage may be allowed depending on the special circumstances of the case. For avoi dance of doubt, while a kitchen of reasonable size ancillary to the recreational activities at development sites without any commercial
Tags:
Loops, Swimming, Swimming pool
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Code of Practice for Precast Concrete Contruction 2016
www.bd.gov.hk2.5.3 Handling and transportation ... Precast concrete elements should be designed and constructed in compliance with the Building (Construction) Regulations and other relevant codes of practice. The design method specified in this code of practice for the design of precast concrete elements is
Practice Note for Authorized Persons, Registered ...
www.bd.gov.hkrequirements for the design and construction of building, street, building works and street works. However, they do not contain reference to any specific prescriptive standard. 2. Appendix A lists those standards or technical criteria accepted by the Building Authority as complying with the performance requirements stipulated in the Regulations.
Code of Practice
www.bd.gov.hkC2 Beams with Intermediate Buckling Restraints 57 C3 Beams with No Intermediate Buckling Restraints 59 C4 Continuously Restrained Beams 60 C5 Buckling Restraints 62 ANNEX D INSPECTION, MAINTENANCE AND REPAIR D1 General 64 D2 Deterioration and Failure of Glazing Systems 64 D2.1 Typical forms of deterioration 64 D2.2 Glass failure 64 D3 Maintenance Management 65
Technical Memorandum for Supervision Plans 2009
www.bd.gov.hk2.1 This Technical Memorandum supplements the provisions of the Buildings Ordinance governing the supervision of building works and street works. 2.2 This Technical Memorandum sets out the principles, requirements and operation of supervision plans. It deals in particular with:- (a) the principles for the preparation of supervision plans;
Central Data Bank List of Building Materials
www.bd.gov.hkIntumescent Coating Protection of steel columns up to 1 hr. FRP. BS 476: Parts 20 & 21: 1987 : N/A : The Loss Prevention Council : TE5944 : November 1986 : N/A : No-objection letter 18/01/2005 : issued in 1990. Required thickness of fire-resisting material should be in accordance with the test report no. TE5944. BD-FP 015 : Glulite Fire ...
Practice Note for Authorized Persons, Registered ...
www.bd.gov.hkHong Kong into a telecommunications, broadcasting and Internet hub in the Asia Pacific region. 2. To enable occupiers of a building to gain access to the full range of quality broadcasting, telecommunications and Internet services, the Telecommunications Authority has, under section 14 of the Telecommunications Ordinance, granted
Practice Note for Authorized Persons, Registered ...
www.bd.gov.hkmodelling, selection of geotechnical parameters and design water pressures, should be adopted. ... Alternatively, soil structure interaction analyses method may be carried out. 3.5.2 In soil structure interaction analyses, there could be a rapid increase in the maximum wall deflection/strut loads upon a small reduction in the wall
Modelling, Soil, Structure, Interactions, Soil structure interaction
Explanatory Notes to - Buildings Department
www.bd.gov.hkBS EN 1991-1-4. This enables shared use of future development work on these standards, and more direct use of data from these standards, where needed to supplement the Code. It may also assist with future convergence. Additional work was also carried out to resolve differences between these standards and to obtain better
Code of Practice for Fire Safety in Buildings 2011
www.bd.gov.hkPart F – Fire Safety Management . Section 1 – General . F1 Use of this Part 164 . F2 Performance Requirements for Fire Safety Management 164 . F3 Scope 164 . Section 2 – Fire Safety Management . F4 Fire Safety Management 166 . Section 3 – Maintenance Plan . F5 Maintenance Plan 168. Section 4 – Training Plan . F6 Training Plan 172
(E) Other Fire Resisting Products (e.g. fire shutter, etc)
www.bd.gov.hkBD-E010 Suzuki Shutter Suzuki Shutter Co. (HK) Ltd. 120 - UKAS Warrington Fire Research Service Ltd WFRC No. C124741 Supplement to WFRC No 120584 20/6/2002 1/7/2007 8/9/2005 BD-E011 Fibreglass Reinforced Plastic (FRP) Panel Architectural Precast GRC Ltd. 30 - The Singapore Accreditation Service PSB Corporation PSB Test Report Ref.
Related documents
DHA CONSTRUCTION & D EVELOPMENT REGULATIONS - …
dhalahore.orgSwimming Pool 28 32. Basement of Residential Area 28 33. Water Tanks 29 . 3 34. Guard Post 29 35. ... after repeal of the Defence Housing Authority Lahore Ordinance 1999 (Punjab Ordinance LI 1999), Chief Executive's Order No. 26 of 2002, for the reconstitution of ... These Regulations shall extend to the Specified as well as Notified area of ...
Loops, Regulations, Construction, 1999, Swimming, Swimming pool, Dha construction
Sloblock Hall - OnTheMarket
media.onthemarket.com• Swimming pool with full kitchen, pool house and gym • Landscaped gardens and grounds ... building regulations or other consent has been obtained. A buyer or lessee must find out by inspection or in other ways ... Tel: +44 117 317 1999
Loops, Regulations, 1999, Swimming, Hall, Swimming pool, Sloblock hall, Sloblock
Installing, modifying and maintaining domestic plumbing ...
www.southernwater.co.ukRegulations 1999 How to use this booklet This booklet is designed to provide ... Ponds and swimming pools Schedule 2.12.31 Any pond, fountain or pool filled or supplied with water by the Water Undertaker should have an impervious lining and be watertight. This requirement only applies to constructed
IntelliConnect Installation Guide
www.pentair.comThis product is intended for use in swimming pool applications only. Most states and local codes regulate the construction, installation, and operation of public ... (1999). installation codes and ordinances must also be adhered to. ... Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and ...
District of Columbia Energy Conservation Code
eservices.dcra.dc.govSwimming Pool and Spa Code® published by the ICC as amended by the District of Colum-bia Construction Codes Supplement of 2017, 12 DCMR L, Swimming Pool and Spa Code Sup-plement)]. 1. The District of Columbia Municipal Regulations (DCMR) is the official compilation of rules and regulations issued by government agencies and