Programmable Resolution 1-Wire Digital Thermometer
the need for an external power supply. Each DS18B20 has a unique 64bit serial code, - which allows multiple DS18B20s to function on the same 1-Wire bus. Thus, it is simple to use one ... provides access to the 1-byte upper and lower alarm trigger registers (T. H. and T. L) and the 1byte - configuration register. The configuration register ...
Tags:
Lamar, External, Programmable, Resolution, Programmable resolution 1
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
SPECIFICATIONS - Adafruit Industries
cdn-shop.adafruit.compage date DESCRIPTION: electret condenser microphone 3 of 4 06/2008 20050 SW 112th Ave. Tualatin, Oregon 97062 pphone hone 503.612.2300 ffax ax 503.612.2383 PART NUMBER: CMA-4544PF-W ENVIRONMENT TEST item test condition high temp. test After being placed in a chamber at +70°C for
FE1.1 USB 2.0 H SPEED 4-PORT H CONTROLLER
cdn-shop.adafruit.comspeed (480MHz) modules, so that all the logic components could be fully tested before shipping. Special Build-In-Self-Test mode is designed to exercise all high, full, and low speed Analog Front End (AFE) components on the packaging and testing stages as well. Low power consumption is achieved by using 0.18μm technology and comprehensive
PL2303TA USB to Serial Bridge Controller Product Datasheet
cdn-shop.adafruit.comMay 04, 2012 · PL2303TA USB to Serial Bridge Controller Product Datasheet Document Revision: 1.1.1 Document Release: May 4, 2012 Prolific Technology Inc. 7F, No. 48, Sec. 3, …
Technical Data Sheet 5mm Infrared LED , T-1 3/4
cdn-shop.adafruit.com․Low forward voltage ․Pb free ․The product itself will remain within RoHS compliant version. Descriptions ․EVERLIGHT’S Infrared Emitting Diode(IR333-A) is a high intensity diode , molded in a blue transparent plastic package. ․The device is spectrally matched with phototransistor , photodiode and infrared receiver module. Applications
TCS3472 COLOR LIGHT-TO-DIGITAL CONVERTER with IR …
cdn-shop.adafruit.comClear Data Red Data Green Data Blue Data RGBC Control Blue Green Red Clear IR-Blocking Filter Detailed Description The TCS3472 light-to-digital converter contains a 3 × 4 photodiode array, four analog-to-digital converters (ADC) that integrate the photodiode current, data registers, a state machine, and an I2C interface. The 3 ×4
Data, Converter, Analog, Digital, To digital, To digital converter
LIGHT-TO-DIGITAL CONVERTER
cdn-shop.adafruit.comanalog-to-digital converters (ADC) that integrate currents from two photodiodes. Integration of both channels occurs simultaneously. Upon completion of the conversion cycle, the conversion result is transferred to the Channel 0 and Channel 1 data registers, respectively. The transfers are double-buffered to ensure that the
Data, Converter, Analog, Digital, To digital, To digital converter
ESP32-WROOM-32 Datasheet
cdn-shop.adafruit.comESP32-WROOM-32 is a powerful, generic Wi-Fi+BT+BLE MCU module that targets a wide variety of applications, ranging from low-power sensor networks to the most demanding tasks, such as voice encoding, music streaming and MP3 decoding. At the core of this module is the ESP32-D0WDQ6 chip*. The chip embedded is designed to be scalable and adaptive.
BMP280 Digital Pressure Sensor - Adafruit Industries
cdn-shop.adafruit.com(e.g. time-to-first-fix improvement, dead-reckoning, slope detection) Indoor navigation (floor detection, elevator detection) Outdoor navigation, leisure and sports applications Weather forecast Health care applications (e.g. spirometry) Vertical velocity indication (e.g. …
BME680 Low power gas, pressure, temperature & humidity …
cdn-shop.adafruit.comCurrent consumption 2.1 µA at 1 Hz humidity and temperature 3.1 µA at 1 Hz pressure and temperature 3.7 µA at 1 Hz humidity, pressure and temperature 0.09‒12 mA for p/h/T/gas depending on operation mode 0.15 µA in sleep mode Operating range -40‒+85 °C, …
2.7V 4-Channel/8-Channel 10-Bit A/D Converters with SPI ...
cdn-shop.adafruit.comJan 02, 2008 · Data Coding Format Straight Binary High Level Input Voltage VIH 0.7 VDD —— V Low Level Input Voltage VIL — 0.3 VDD V High Level Output Voltage VOH 4.1 — — V IOH = -1 mA, VDD = 4.5V Low Level Output Voltage VOL —— 0.4 VIOL = 1 mA, VDD = 4.5V Input Leakage Current ILI-10 — 10 µA VIN = VSS or VDD Output Leakage Current ILO-10 ...
Related documents
2GIG Control Panel User Guide - Protection 1 Home Security
www.protection1.comsiren and an external siren (if installed) sounds for a preset time. During alarms and after disarming, alarm history button displays all the alarms that have occurred, and which sensors were involved. The alarm history clears the next time the system is armed or can be cleared manually. Messages
Guide, User, Control, Panels, Lamar, External, Control panel user guide
CONFIDENTIAL MOTOMAN INSTRUCTIONS MOTOMAN- …
assets.efc.gwu.eduThe YRC1000 alarm codes above consists of “MAJOR ALARMS” and “MINOR ALARMS”. 1/142 178938-1CD 1 CONFIDENTIAL NOT FOR EXTERNAL USE. ii HC1400033 HC1400033 DANGER • This manual explains maintenance mode (a setup, maintenance, etc.) of the YRC1000 system.
Rubin i-xiv 1-16 4p
api.gretchenrubin.com1 JANUARY Boost Energy ... read that even a tiny light from a digital alarm clock can disrupt a sleep cycle, and it’s like a mad scientist’s lab in here. Our BlackBerrys, the com- ... vation, people act to win external rewards or avoid external punishments;
Automated External Defibrillator (AED) Monthly Inspection
njmel.org1 Is the AED case accessible and highly visible? There should be nothing that obstructs or obscures the AED from quickly finding and accessing it for use. 2 Does the AED case alarm properly? Check that the case sounds the alarm if opened, and if provided, sends a signal to a monitoring location. 3 Is the AED intact and free of damage?
DS K1T804 Series - Hikvision
www.hikvision.comAug 02, 2017 · RS485 : 19200 bps -N-8-1 Input Interface Exit Button × 1, Door Sensor × 1 and Alarm Input × 1 Output Interface Relay (Lock Output) × 1, and Alarm Output × 1 USB USB 2.0 ; Type A LCD Screen 2.4-inch (320 × 240 LCD -TFT Display Screen) Audio 1 Buzzer and 1 Loudspeaker LED Indicator Power/Status (Red/Green ) Power Supply 12 VDC/2 A
Programmable Resolution 1-Wire Digital Thermometer
cdn.sparkfun.compowered from an external 3 volt - 5.5 volt supply. Communication to the DS18B20 is via a 1-Wire port. With the 1-Wire port, the memory and control functions will not be available before the ROM function protocol has been established. The master must first provide one of five ROM function commands: 1) Read ROM, 2) Match ROM, 3) Search ROM, 4)
700/70 Series HANDBOOK - MITSUBISHI ELECTRIC Global …
dl.mitsubishielectric.comRemedy - Disable the "tool length measurement 1" signal and move the axis in a safe direction. - Disabling the sensor signal also clears the operation alarm. (Note) When the "tool length measurement 1" signal is disabled, the axis can be moved in either direction. Pay attention to the movement direction. M01 Ref point retract invalid 0020
Installation Manual
www.eltek.comMay 26, 2010 · A dual feed architecture is powers rectifier slots 1 and 3 on AC feed 1 and rectifier slots 2 and 4 on AC feed 2. The ground wires should be connected first; there are two ¼”-20 studs provided next to the terminal block (see Figure 7). Connect each feed, sized according to specifications in Table 3, onto the #8-32 screw on the rear terminal ...