Proportional Directional Control Valves - Eaton

Directional Control Valves K(A)DG5V-5/7/8 & KDG5V-10, 1* Series, Two-Stage Models without Electrical Feedback ISO 4401 Sizes 05, 07,08 and 10 product has been designed and tested to meet specific standards outlined in the EuropeanElectromagnetic Compatibility Directive (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and93/68/EEC, article 5. For instructions on installation requirements to achieve effective protection levels, seethis leaflet, the Installation Wiring Practices for Vickers Electronic Products leaflet 2468 and leaflet 02-123931 Awhich is packed with every KA valve. Wiring practices relevant to this Directive are indicated byElectromagnetic Compatibility (EMC).5052/EN/1097/AVickers Proportional KDG5V-5/7/8/10 are solenoidoperated Directional controlnon-feedback type Proportional Proportional Directional controlvalves in which the main-stage spool ispositioned according to the output from anintegrally mounted Proportional ,solenoid-operated , pressure-reducingvalve.

B.2 Introduction Vickers KDG5V-5/7/8/10 are solenoid operated directional control non-feedback type proportional valves. Two-stage proportional directional control