Straumann SmartOneStage 3 | Prosthetic proceduresStep 1 Impression-taking2 Prosthetic proceduresStep 2 | Impression-takingOverviewStraumann SmartOneAssessment and treatment planningProsthetic proceduresAftercare and maintenance In clinic with patient Office / Lab workStep 1 | History and examinationSurgical proceduresStep 1 | Implant surgeryStep 1 | Review visitStep 3 | Consultation and consentStep 2 | Fabrication of the final prosthesisStep 2 | Treatment planningStep 1 | Impression-takingStep 2 | Post-operative review and suture removalStep 2 | Maintenance visit step 4 | Fabrication of the surgical drill templateStep 3 | Insertion of the final prosthesis7 10 days3 6 months (or as necessary)6 8 weeks2 weeksStep 1 | Patient's expectations, history and examination3 Prosthetic proceduresStep 2 | Impressio
this wax will occlude the head of the screw in order to allow retrievability of the screw by the SCS Screwdriver. 7. Apply a light-bodied elasto-meric impression material (e.g., light-bodied polyvinyl siloxane or polyether rubber) around the RN synOcta® Impression Post. 6 7 7a 5 5. Customize the prefabricated tray provided by the dental lab, or a