Transcription of SULFUR DIOXIDE 6004
{{id}} {{{paragraph}}}
SULFUR DIOXIDESULFUR DIOXIDE 6004SO2 MW: CAS: 7446-09-5 RTECS: WS4550000 METHOD: 6004, Issue 2 EVALUATION: PARTIALI ssue 1: 15 May 1989 Issue 2: 15 August 1994 OSHA :5 ppmNIOSH: 2 ppm; STEL 5 ppm; Group I PesticideACGIH: 2 ppm; STEL 5 ppm(1 ppm = mg/m3 @ NTP)PROPERTIES:gas; vapor density (air = 1); BP -10 C; MP C;nonflammable SYNONYMS:noneSAMPLINGSAMPLER: FILTER + TREATED FILTER (cellulose + Na2CO3; preceded m cellulose ester membrane)FLOW to L/minVOL-MIN:4 L @ 5 ppm -MAX:200 LSHIPMENT:routineSAMPLE STABILITY:not determinedFIELD BLANKS:2 to 10 field blanks per setMEASUREMENTTECHNIQUE:ION CHROMATOGRAPHYANALYTE: sulfite and sulfate ionsEXTRACTION: 10 mL mM NaHCO3 mM Na2CO3 INJECTION LOOP VOLUME: 50 mM NaHCO3 mM Na2CO3,2 to 3 mL/minCOLUMNS: Ion Pac AS4A separator, Ion Pac AG4 Aguard; micromembrane suppressor [2]CONDUCTIVITY SETTING:10 S full scaleCALIBRATION: standard solutions of SO32 - and SO42 -in eluentRANGE: 11 to 200 g SO2 per sampleESTIMATED LOD: 3 g SO2 per sample [2]PRECISION (S r) [2]ACCURACYRANGE STUDIED:not studiedBIAS: not determinedOVERALL PRECISION (S rT):not determinedACCURACY.
OTHER METHODS: This revises P&CAM 268 [3]. P&CAM 146 [4], P&CAM 163 [5], and S308 [6] use 0.3 N H 2O 2 for sampling, followed by titration with NaOH or barium perchlorate. P&CAM 160 [7] uses tetrachloromercurate solution and visible spectrophotometry. P&CAM 204 [8] uses a solid sorbent (molecular sieve 5A), thermal desorption, and mass ...