Suspended Acoustical Ceiling Products Key components for suspended acoustical ceilings are suspension grid and acoustical panels. Composition of each can vary depending on the end-use application.Acoustical tile (305 x 305 mm (12 x 12 )) is also an acoustical ceiling product, but unlike larger panels (610 x 610 mm
Download Acoustical Ceiling Design & Application
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
USG Fire-Resistant Assemblies Catalog (English) - …
www.usg.com4 USG Fire-Resistant Assemblies Fire Protection USG is the undisputed leader among building material manufacturers in providing products and systems designed to keep people safe from fire.
USG Area Separation Wall Systems Brochure …
www.usg.comArea separation walls between adjoining townhouses must provide fire-resistive ratings to ensure the safety of occupants in adjacent dwellings.
System, Area, Safety, Walls, Brochure, Separation, Usg area separation wall systems brochure
Fire-Resistant Assemblies Brochure (English) - SA100
www.usg.comUser’s Guide Use this brochure to determine fire ratings for CGC products and systems. This brochure provides: — Comprehensive information about fire-rated assemblies
Fire, English, Brochure, Resistant, Assemblies, Fire resistant assemblies brochure, Sa100
Technical Document Seismic Technical Guide - USG
www.usg.com4 Hanger Wire Attachment Application Anchorage The International Building Code (IBC), through references to ASCE/SEI 7 Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers/Structural Engineering Institute (ASCE/SEI), defines
American, Guide, Design, Seismic, Document, Engineer, Technical, Society, Case, Minimum, Load, Civil, American society of civil engineers, Technical document seismic technical guide, Sei 7 minimum design loads
Technical Document Seismic Technical Guide - USG
www.usg.comTechnical Seismic Technical Guide Document Light Duty Suspension Systems ASTM C6351 addresses the load carrying capability of main tees, categorizing them as Light, Intermediate or Heavy Duty.
CGC SHAFT WALL SYSTEMS - USG
www.usg.comC-H studs in a progressive manner, with gypsum panels, gypsum fiber panels or cement board applied to the face. All details, specifications and data contained in this literature are intended as a …
USG DUROCK BRAND CEMENT BOARD SYSTEMS
www.usg.comSTANDARDS USG Durock® cement board exceeds ANSI standards for cementitious backer units (CBU). See ANSI A118.9 for test See ANSI A118.9 for test methods and specifications for CBU and ANSI A108.11 for interior installation of CBU.
Manual Técnico USG Tablaroca® (Español)
www.usg.comUSG Manual Técnico USG TABLAROCA® USG SHEETROCK® Manejo, almacenaje, especificación, instalación y recomendaciones generales.
0 ICC-ES Evaluation Report ESR-1222 - USG
www.usg.comThe USG suspended ceiling framing systems described in this report are suspended, exposed framing, concealed ceiling assemblies used in fire-rated and non -resistance -
Technical Document Seismic Technical Guide - USG
www.usg.comTechnical Seismic Technical Guide Document Compression Posts USG Donn® Brand Compression Post providesidrig support for a ceiling suspension system in seismic applications. Telescoping compression posts attach to the main tees at each splayed wire location, preventing upward
Guide, Seismic, Document, Technical, Technical document seismic technical guide
Related documents
USG DUROCK BRAND CEMENT BOARD SYSTEMS
www.usg.comTwo-Hour Fire-Rated Construction Chase Walls, Steel Framed Acoustical Performance Construction Detail Description Test Number STC Test Number 9" • 1/2" USG Durock® Brand cement board and 1/4" ceramic tile – Two rows 2 x 4 wood studs 16" o.c. on 2 x 8 common plate – 3-1/2" Thermafiber® SAFB™ both cavities – Joints taped
WALL & FLOOR ASSEMBLY GUIDE - Owens Corning
insulation.owenscorning.caThe effective acoustical performance of walls can be greatly affected by a number of design and construction details. These details include sealing the perimeter of walls, construction details of wall intersections, size and placement of windows, the location and proper installation of doors, electrical outlets, ducts, and mechanical equipment.
Flexible Duct Performance & Installation Standards
airductcouncil.orgASTM E477 - Duct Liner Materials and Prefabricated Silencers for Acoustical and Airflow Performance ASTM C518 - Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter NFPA Standard 90A - Installation of Air Conditioning and Ventilating Systems NFPA Standard 90B - Warm Air Heating and Air Conditioning Systems
Performance, Installation, Standards, Flexible, Acoustical, Duct, Flexible duct performance amp installation standards
DETAILS
www.armstrongceilings.comTraditional Acoustical Grid 5 SHADE POCKETS For more information, call 877 276-7876 Armstrong Ceiling Solutions Axiom ... performance, and perfect integration with all Armstrong ...
SEISMIC CEILING INSTALLATION
www.armstrongceilings.comSeismic performance during large California earthquakes prompted FEMA to address suspended ceiling performance during a seismic event. Research and tests demonstrated that industry seismic standards (UBC Standard 25-2) were not adequate. To support individual panels around the perimeter, FEMA determined that the key to good seismic
Performance, Installation, Seismic, Ceiling, Seismic ceiling installation
DCA1 Flame Spread Performance of Wood Products Used …
www.awc.orgAppearance, acoustical qualities, and interior de-sign versatility have made wood surfaces highly de-sired by architects, designers, and building ocupants. c This publication briefly describes building code flame spread regulations on products used in interior finish and presents performance data on a range of wood products. Flame Spread ...
Performance, Product, Woods, Acoustical, Spreads, Flame, Flame spread performance of wood products
Sound Control for Improved Outcomes in Healthcare Settings
www.healthdesign.orgty. A well-designed acoustical environment is critical in addressing these problems related to noise and communication of information. Noise levels can be effectively reduced by providing single-patient bed-rooms, installing high-performance sound-absorbing acoustical ceiling tiles, and removing or reducing loud noise sources on hospital units.
TRIFAB VG (VERSAGLAZE TRIFAB VG 450, 451 & 451T …
www.kawneer.comPERFORMANCE TEST STANDARDS Air Infiltration ASTM E283 Water AAMA 501, ASTM E331 Structural ASTM E330 Thermal AAMA 1503 Thermal Break AAMA 505, AAMA TIR-A8 Acoustical AAMA 1801, ASTM E1425 Thermal simulations showing temperature variations from exterior/cold side to interior/warm side. Trifab ® VersaGlaze 451 Trifab VersaGlaze® 451T …
Acoustical Assemblies Brochure SA200
www.montana.eduLoadbearing Acoustical Performance Fire Performance Reference Construction Detail Description STC Test Number Rating Test Number ARL Index wt. 7 • 5/8 SHEETROCK Brand FIRECODE Core 1 hour UL Des U305, SA920 A-25 Gypsum Panels or FIBEROCK Brand Panels U314 – 2x4 wood stud 16 or 24 o.c.
USG USG MARS HEALTHCARE Ceiling ACOUSTICAL PANELS ...
www.usg.comACOUSTICAL PANELS CLIMAPLUS™ PERFORMANCE WITH CLEAN ROOM, HIGH-NRC AND AIRCARE™ COATING OPTIONS TO ORDER SAMPLES, GO TO USG.COM OR CGCINC.COM White 050 FEATURES AND BENEFITS • Water-repellent membrane designed to be durable and safewith common disinfectants.** • Washable and soil-resistantfi nish. Impact …