IQ Range - Rotork
Inside the IQ Actuator 6 Actuator Selection for Linear Valve Types 8 Actuator Selection for Part-turn Valve Types 9 Design Features 10 Rotork Master Station Network Capabilities 16 Fieldbus Compatibility 17 Actuator Specification (full contents list on p19) 19 Performance Summaries 20 Actuator Drive Couplings 26 Standard Specifications 28
Download IQ Range - Rotork
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
CP Range - rotork.com
www.rotork.comUS A4 US A4 US A4 US A4 A4 US US A4 US A4 A4 US Redefining low Control 5 30 14 26, 27, 28 31 7 30 14 4 1 18A 2, 3 19 15 23 * Quantity (2) for double-acting, (3) …
Solenoid Valves - Rotork
www.rotork.comRotork is committed to providing first class support to each client throughout the whole life of their plant, from initial site surveys to installation, maintenance, audits and repair. From our network of national and international offices, our engineers work around the clock to maintain our position of trust. Rotork. Keeping the world flowing.
IQ Range Installation and Maintenance Instructions
www.rotork.comThe on board Datalogger captures operational and valve torque data enabling informed maintenance choices to be made. IQ Insight software for PC and PDA allows the Datalogger to be interrogated, as well as the complete actuator set up to be configured and recorded. The actuator containing the Setting Tool will be identified with a yellow
ROTORK RANGE
www.rotork.comof the Rotork IQ Range actuator be required, this will be provided on request. Health and Safety 1 2 WARNING: With respect to the handwheel operation of Rotork electric actuators, under no circumstances should any additional leaver device such as a wheel-key or wrench be applied to the handwheel or in order to develop more force
RC200 Pneumatic Actuators - Rotork
www.rotork.com1 Nm = 0,102 kpm = 8,85 Ib.in. 1 kpm = 9,81 Nm = 86,8 Ib.in. 1 Ib.in = 0,113 Nm = 0,0115 kpm Pressure 1 Mpa = 10 bar = 10,2 kp/cm² = 145 psi 4 Size Torque in Nm. Air pressure 0,6 Mpa (6 bar / 87 psi) Air opens Spring closes 7400 3570 5400 15250 7200 11350 3800 1900 2740 7600 3800 5480 1296 609 921 1890 940 1360 450 225 320 910 460 650 145 72 ...
Piston Actuated Valves Catalogue
www.rotork.com6 Piston Actuated Valves Catalogue USA4 US A4 US A4 US A4 A4 US A4 US A4 A4 US Valve Selection Piston actuated valves use an external control medium to pilot the actuator, where a piston is directly connected to the main seal that closes onto the main orifice, thereby controlling the flow of liquids and gases.
IQT Range - Rotork
www.rotork.comfor more information on the IQ, Insight2 and other Rotork actuator ranges. 2. Health and Safety This manual is produced to enable a competent user to install, operate, adjust and inspect Rotork IQT range valve actuators. Only persons competent by virtue of their training or experience should install, maintain and repair Rotork actuators. Under ...
CP Spring Return Series Actuators
www.rotork.comCP Spring Return Series Actuators Dimension Data (metric) Date 16/05/2018 Revision 0. Spring return (drawing) 2 of 13. CP Series SPRING RETURN, PNEUMATIC ACTUATOR - Dimensional Data 3 of 13 CP/S-035-080*/AA F07 589 167 422 112 43 71,5 35 116,5 51,5 19 6,5 98,5 27 24 22 16 60 60 100 49,5 M8 10,5 13 49,25 100 5 80 80 40 M10 10 13 0,5 1/4" 16 141 ...
Series, Return, Pneumatic, Spring, Actuator, Spring return, Cp spring return series actuators
IQ Range - Rotork
www.rotork.comUninterruptible power supplies ... PUB002-021 IQ single-phase power supply rating data. IQD – DC power supplies IQD10, IQD12, IQD20 and IQD25 are available for standard nominal voltages: 24 V*, 48 V*, 110 VDC ... special high torque low inertia design. 15 minute rated with
Power, Supply, Power supply, Uninterruptible, Uninterruptible power
IQ Range - Rotork
www.rotork.com1.3 Introduction to this manual This manual provides instruction on: • Manual and electrical (local and remote) operation. • Preparation and installation of the actuator onto the valve. • Basic commissioning. • Maintenance. Refer to Publication PUB002-047 for repair, overhaul and spare part instructions. Refer to Publication PUB002-040
Related documents
Toyota Extra Care Platinum - Toyota Financial
www.toyotafinancial.comA TOYOTA EXTRA CARE VSA OFFERS: • Protection for applicable vehicle components after your vehicle warranty expires1 • 24/7 Roadside Assistance throughout the life of your Agreement
Toyota Extra Care Platinum - Toyota Financial
www.sc.toyotafinancial.comOur highest level of protection — the Toyota Extra Care Platinum VSA. Platinum VSA covers the cost of mechanical breakdown of the parts listed below after your vehicle’s warranty expires.2 Your vehicle’s Limited Powertrain Warranty covers only those parts listed in BLACK text.
HGJAA (Spec J) HGJAB (Spec J-K) - Grand Design
www.granddesignrv.com• Electric shock • Exhaust carbon monoxide (CO) 1.5 Electrical Shock and Arc Flash Can Cause Severe Personal Injury or Death WARNING Electrical shocks and arc flashes can cause severe personal injury or death. Adhere to the following guidelines: • Only qualified service personnel certified and authorized to work on power circuits should