OIML R 76-1 Edition 2006
International Recommendations (OIML R), which are model regulations that establish the metrological characteristics required of certain measuring instruments and which specify
Download OIML R 76-1 Edition 2006
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
OIML R 111-1 (E) Edition 2004
www.oiml.orgOIML R 111-1: 2004 (E) 3 T he International Organization of Legal Metrology (OIML) is a worldwide, intergovernmental organization whose primary aim is …
Organisation Internationale de Métrologie Légale
www.oiml.orgTERMINOLOGY (terms and definitions) The terminology used in this Recommendation conforms to the International Vocabu- lary of Basic and General Terms in Metrology(VIM, 1993 edition) and the ...
International, General, Basics, Metrology, Basic and general
GUIDE OIML G 1-100
www.oiml.orgThe JCGM’s publications may be reproduced, provided written permission has been granted by the JCGM. A sample of any reproduced document shall be provided to the JCGM at the time of reproduction and contain the following statement: This document is reproduced with the permission of the JCGM, which retains full internationally protected
OIML R 76-1 Edition 2006
www.oiml.orgIn case of doubt as to whether an instrument is a non-automatic weighing instrument or an automatic weighing instrument, the definitions for automatic weighing instruments given in OIML Recommendations R 50, R 51, R 61, R 106, R 107 and R 134 have higher priority than the …
G ILAC-G24 I OIML D 10 S
www.oiml.orgchecking, controlling and maintaining measurement standards, reference materials used as measurement standards, and measuring and test equipment used to perform tests and calibrations. ISO 9001:2000 [10] contains the requirement: Clause 7.6: “Where necessary to ensure valid results, measuring equipment shall:
RECOMMANDATION OIML R 111-1 INTERNATIONALE Édition …
www.oiml.orgPour poids pris à la température de référence (tref) de 20 °C, la masse conventionnelle est la masse d’un poids de référence d’une densité ( ref) de 8000 kg m –3 qu’elle équilibre dans un air de masse volumique de 1,2 kg·m –3. 2.8 Densité d’un corps Masse divisée par le volume, donné par la formule = m / V 2.9 Magnétisme
Organisation Internationale de Métrologie Légale — Français
www.oiml.orgCreated Date: 11/30/2004 4:01:30 PM
OIML R 87 Edition 2016
www.oiml.orgThis publication reference OIML R– 87, Edition 2016(E) – was developed by Project Group 3 in Technical Committee TC 6 . Prepackaged products. It was approved for final publication by the International Committee of Legal Metrology in 2016 and was submitted to the International Conference on Legal Metrology in 2016 for formal sanction.
OIML R 111-1 (E) Edition 2004
www.oiml.orgOIML R 111-1: 2004 (E) 5 2 TERMINOLOGY The terminology used in this Recommendation conforms to the International Vocabulary of Basic and General Terms in Metrology(1993 edition) [1] and the International Vocabulary of Terms in Legal Metrology(2000 edition) [2]. In addition, for the purposes of this Recommendation, the following definitions apply.
INTERNATIONAL OIML R 49-1 RECOMMENDATION Edition …
www.oiml.org[Source: OIML V 2-200:2012 (VIM) [1] 3.8, modified“meter” replaces —“ measuring system”.] Note: For a water meter, the sensor may be a disc, piston, wheel or turbine element, the electrodes on an electromagnetic meter, or another element. The element senses the flow rate or volume of water
Related documents
OIML R 85-1 & 2 Edition 2008 - fundmetrology.ru
www.fundmetrology.ruOIML R 85-1 & 2:2008 (E) 4 Foreword The International Organization of Legal Metrology (OIML) is a worldwide, intergovernmental organization whose primary aim is to harmonize the regulations and metrological controls applied by the national
Issue 2 May 2013 WELMEC - European Legal …
www.welmec.orgWELMEC 6.8 Issue 2 May 2013 WELMEC European Cooperation in Legal Metrology Drained Weight Guide on the Verification of Drained Weight, Drained
OIML R 111-1 (E) Edition 2004
www.oiml.orgOIML R 111-1: 2004 (E) 3 T he International Organization of Legal Metrology (OIML) is a worldwide, intergovernmental organization whose primary aim is …
INTERNATIONAL OIML R 49-2 RECOMMENDATION …
www.fundmetrology.ruOIML R 49-2:2013 (E) Foreword The International Organization of Legal Metrology (OIML) is a worldwide, intergovernmental organization whose primary aim is to harmonize the regulations and metrological controls applied by the national
OIML R60-1 WD - National Measurement Institute, …
www.measurement.gov.auReference number: OIML R60-1 3CD . Supersedes document: R60 (2000) OIML TC 9 : Instruments for Measuring Mass and Density Circulated to P- and O-members and
CALIFICACIÓN METROLÓGICA DE PESAS PATRONES
www.cenam.mxSimposio de Metrología 2004 25 al 27 de Octubre CALIFICACIÓN METROLÓGICA DE PESAS PATRÓN SEGUN OIML R 111 Luiz Roberto Oliveira da Silva A Marcelo Lima Alves B A Centro Federal de Educação Tecnológica do Rio de Janeiro
G ILAC-G24 I OIML D 10 S - etaloniranje
www.etaloniranje.comILAC-G24:2007 / OIML D 10:2007 (E) 5 Guidelines for the determination of calibration intervals of measuring instruments Preamble This Guidance Document is a revision of OIML D 10.
OIML R 117-1 Edition 2007 - Flowmeters
www.flowmeters.nlOIML R 117-1: 2007 (E) 4 Foreword The International Organization of Legal Metrology (OIML) is a worldwide, intergovernmental organization whose
CHAP1ny - Gilson Engineering Sales
www.gilsoneng.comSFIDK.PS.027.W6.02 SITRANS F M Siemens Flow Instruments range of electromagnetic flowmeters 2 MAG 1100 MAG 1100 F MAG 3100 MAG 3100 P MAG 5100 W