Technical Data Sheet
Dry abrasive blast cleaning to SSPC-SP 13/NACE No. 6. Galvanised steel The surface shall be clean, dry and appear with a rough and dull profile. Sweep blast-cleaning using non-metallic abrasive leaving a clean, rough and even pattern. Coated surfaces Clean, dry and undamaged compatible coating Clean, dry and undamaged compatible coating
Download Technical Data Sheet
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Technical Data Sheet - Jotun
www.jotun.comTechnical Data Sheet Hardtop Flexi The provided data is typical for factory produced products, subject to slight variation depending on colour. Gloss description: According to …
Technical Data Sheet Application Guide
www.jotun.comEpoxy HR Product description This is a two component polyamine cured phenolic/novolac epoxy coating. It is heat resistant up to 205 °C (401 °F) and can be applied on hot substrates up to 150 °C (302 °F).
Technical Data Sheet
www.jotun.comTechnical Data Sheet Epoxy HR Surface preparation summary table Substrate Minimum Recommended Carbon steel St 2 (ISO 8501-1) Sa 2½ (ISO 8501-1) Stainless steel The surface shall be hand or machine
Technical Data Sheet Application Guide
www.jotun.comApplication Guide 3140;3240;4320 1,2 3140 Scope The Application Guide offers product details and recommended practices for the use of the product. The Application Guide (AG) must be read in conjunction with the relevant specification, Technical Data Sheet (TDS) and Safety Data Sheet (SDS) for all the products used as part of the coating system.
Technical Data Sheet - Jotun
www.jotun.comOptimum performance, including adhesion, corrosion protection, heat resistance and chemical resistance is achieved with recommended surface preparation. Date of issue:22 March 2021 Page: 3/7 This Technical Data Sheet supersedes those previously issued.
Technical Data Sheet - Jotun
www.jotun.comPackaging (typical) The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary due to local regulations. Size of containers (litres) Aluminium Paint H.R. 5 5 Storage Volume (litres) Depending on the actual exposure of the coating system, various primers and topcoats can be used in
Technical Data Sheet Jotamastic 87 Aluminium
www.jotun.comPackaging (typical) The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary due to local regulations. Size of containers Jotamastic 87 Wintergrade Comp B 4 5 (litres) Jotamastic 87 Standard Comp B 2.7 Jotamastic 87 Aluminium Comp A 14.7 20 3 Volume (litres) Date of issue:27 June 2017 Page ...
Technical Data Sheet
www.jotun.comLEED®v4 (2013) MR credit: Building product disclosure and optimization - Material Ingredients, Option 2: Material Ingredient Optimization, International Alternative Compliance Path - REACH optimization: Fully inventoried chemical ingredients to 100 …
Technical Data Sheet
www.jotun.comThis is a two component amine cured epoxy coating. It is a fast drying, zinc phosphate pigmented, high solids, high build product. Specially designed for new construction where short dry to handle and over coating times are required. Can be used as primer, mid coat, finish coat or as single coat system in atmospheric environments.
SAFETY DATA SHEET - Jotun
www.jotun.com1.3 Details of the supplier of the safety data sheet Product type :Liquid. Product description :Paint. 1.2 Relevant identified uses of the substance or mixture and uses advised against SECTION 1: Identification of the substance/mixture and of the company/ undertaking Product code :3140 1.4 Emergency telephone number SAFETY DATA SHEET
Related documents
Surface Preparation Standards
monarchindia.netSSPC.SP1 SP1 Definition Hand Tool Clean SSPC.SP2 SP2 Definition 31 GP 401 St. 2 (approx.) Power Tool Clean SSPC.SP3 SP3 Definition 31 GP 402 St. 3 Flame Clean (new steel) SSPC.SP4 31 GP 403 White Metal Blast SSPC.SP5 SP5 Definition SP5 Picture NACE #1 31 GP 404 Type 1 Sa. 3 BS4232 First Quality Commercial Blast SSPC.SP6
Interzone - AkzoNobel
international.brand.akzonobel.comJun 07, 2010 · For immersion service, Interzone 485 must be applied to surface blast cleaned to a minimum of SSPC SP10 or Sa2½ (ISO 8501-1:2007). However, for atmospheric exposure Interzone 485 may be applied to surfaces prepared to a …
Chartek 1709 - AkzoNobel
international.brand.akzonobel.comNov 20, 2017 · Chartek 1709 is a high performance epoxy intumescent fire protection coating system. DESCRIPTION The product is a high build, two pack material providing excellent durability and combined corrosion and fire protection. ANSI/UL 1709 tested and Exterior Listed by Underwriters Laboratories (UL) for fire durations up to 4 hours.
Interlac 665 - AkzoNobel
marinecoatings.brand.akzonobel.comNov 13, 2015 · contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning. SURFACE PREPARATIONS NEWBUILDING/MAJOR REFURBISHMENT Interlac 665 should always be applied over a recommended primer coating scheme. The …
MAIN TYPES OF PAINT USED WITH STEEL: STANDARDS ...
www.canam-construction.comin compliance with the SSPC-SP6/NACE No. 3 standard for surface preparation, which specifies a minimum surface profile of two mils. In certain cases, zinc primers can meet Class B requirements for friction coefficient in connections. 2. Epoxy Epoxy coatings are two-component paints that offer much greater rust protection
STANDARD SPECIFICATIONS for CONSTRUCTION and …
www.roads.maryland.govAug 21, 2004 · 464-Epoxy Protective Coating for Concrete 494 465-Miscellaneous Coating for Metal (Steel) 496 469-Porous Backfill 500 470-Utilities on Structures 501 496-Application of Bridge Structure Numbers 503 499-Working Drawings 504 CATEGORY 500 – PAVING 506 501-Aggregate Base Courses 506 502-Soil-Cement Base Course 510 503-Chip Seal Surface …