TECHNICAL DATA SHEET - Henry
split-back film and apply pressure to assure adhesion. Surface must be rolled after application with a countertop or J-roller with ... Use pre-cut rolls of Blueskin® SA, Blueskin® WB or Blueskin® Butyl Flash for sill pan flashings per
Sheet, Data, Technical, Flashings, Split, Technical data sheet
Download TECHNICAL DATA SHEET - Henry
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
HE784 - AQUA-BLOC® WB - henry.com
henry.comLimited Warranty We, the manufacturer, warrant only that this product is free of defects, since many factors which affect the results obtained from this product - such as weather, workmanship, equipment utilized and prior condition of the substrate - are
TECHNICAL DATA SHEET
henry.comREVISION: 11/17/15 Henry Company, 999 N. Sepulveda Blvd., Ste. 800, El Segundo, CA 90245 Technical Services - Phone: (800) 486-1278 – Email: techservices@henry.com www.henry.com Henry CM100 Fast Curing, Elastomeric Fluid Membrane Uses Henry CM100 may be used as a waterproofing and roofing membrane on horizontal or vertical surfaces. Ideal alternative to hot
TECHNICAL DATA SHEET - Henry
henry.comImpermeable to air, moisture vapor and water Compatible with Henry® Air-Bloc fluid applied air barriers Self-gasketing when penetrated and under compression with self-tapping screws Usage Blueskin SA is designed for use as a self-adhered air, vapor and water resistive barrier. It can also be used as a transition sheet
Sheet, Data, Technical, Barriers, Water, Technical data sheet, Resistive, Air barrier, Water resistive
Henry Blueskin VP160 Air Barrier System Installation Manual
henry.com3 1. Introduction This installation manual includes materials and installation procedures for Henry® Blueskin® VP160 Self-Adhered Water Resistive Air Barrier system. Blueskin® VP160 meets the current IBC and IECC air barrier requirements for a water resistive barrier (WRB) as referenced in ICC ESR-2975.
Installation, Water, Resistive, Water resistive, Water resistive air
TECHNICAL DATA SHEET - Henry
henry.comAir Permeance - Material @1.57psf (75Pa) 0.0001 cfm/ft² (0.0005 L/[sec-m²]) ASTM E2178 Air Leakage - Assembly Pass ASTM E2357 Elongation 250% ASTM D412 Tensile Strength 140 psi (965 kPa) ASTM D412 Flame Spread Index 10, Class A ASTM E84 Smoke Developed 15, Class A ASTM E84 Fire Testing Complies with NFPA 285 in various wall
Sheet, Data, Testing, Technical, Technical data sheet, Leakage, Air leakage
Henry 925 BES Sealant
henry.comHenry® 925 BES Sealant is a premium, moisture cure sealant for construction joints subject to dynamic joint movement. This one-part, low odor, moisture cure product provides excellent weathering resistance, flexibility, very low VOC, through use of a silyl-terminated polyether (STPE) polymer. Upon curing, it is paintable with latex based paints.
Air-Bloc All Weather STPE
henry.comHenry® Air-Bloc All-Weather STPE is a low VOC, UV and fire-resistant fluid applied, elastomeric membrane designed to provide a vapor permeable, water resistive air barrier when applied to above-grade wall assemblies. It is single-component, moisture cure
Water, Step, Weather, Resistive, Water resistive air, All weather stpe
TECHNICAL DATA SHEET Blueskin WP200 - Henry
henry.comREVISION: 02/27/17 Henry Company 999 N. Sepulveda, Ste 800, El Segundo CA 90245-2754 Technical Services- Phone (800) 486-1278 – Email: techservices@henry.com www.henry.com Blueskin WP 200 Self-Adhesive Waterproofing Membrane Uses Blueskin WP200 is designed for use as a self-adhered s heet waterproofing membrane in above or below grade applications.
Sheet, Data, Data sheet, Heet, Sh eet
Air & Water Barrier Membrane - Henry
henry.comConcrete . ASTM C836 load suction pressure-Low Temperature Flexibility and Crack Bridging @ –20°C . ASTM C836 -Aging-Long Term Flexibility . CGSB 71 -GP-24M -Nail Sealability . ASTM D1970 --Resistance to Mold, Mildew & Fungal growth . ASTM D5590 . ASTM E84-VOC Content . Gray . 60% . 10.8 lbs/gal (1.3 kg/l) 2 Hours to touch dry . 24 Hours to ...
WATERPROOFING SYSTEMS - Henry
henry.comSecondary Containment Structures • Tunnels • Underground ... Drainage & Irrigation Channels • Potable Water Reserves • Seals Embedded Steel, PVC or HDPE Pipe Penetrations HENRY DRAINAGE COMPOSITES: A BETTER ENGINEERED SOLUTION FOR MANAGING THE FLOW OF WATER ... highway drainage systems.
Related documents
Sample Inspection Report
www.mjsinspections.comThis is an average quality, 3-year-old (approximate age), “split level”-style, single family home. As with all homes, ongoing maintenance is required and improvements to the systems of the home will be needed over time. The improvements that are recommended in this report are not considered unusual for a home of this age and location. Please
SCOPE OF WORK CHECK LIST - Home | AIA Professional
content.aia.orgLeveling compound at modular split lines Stairs, landings and ramps Bollards, barriers Division 4 – Masonry Division 5 - Metals Base plates embedded in foundation Exterior stairs, landings and ramps Metal flashings at modular split lines Fascia and soffit trim Exterior railings and guardrails Roof scuppers/downspouts Metal cladding at modular ...
1.0 Roofing - .NET Framework
hcloud.blob.core.windows.netMetal flashings are used wherever the roof changes direction or meets an obstruction such as a chimney. When the flashings rust, a section of the roof may have to be removed to install a new flashing. This is an expensive proposition. Copper and lead flashings are expensive, but last longer than galvanized steel or aluminum flashings.
Installation Guide - Windows -- 400 Series - Complementary ...
www.andersenwindows.comreflective flashings. • Do not apply any type of film to glass. Thermal stress conditions resulting in glass damage could occur. • Use of movable insulating materials such as window coverings, shutters, and other shading devices may damage glass and/or vinyl. In addition, excessive condensation may result causing deterioration of windows ...
Standard Details for Metal Roofing & Siding
www.bestmaterials.comup, so that upper flashings are lapped on top of lower flashings. This will prevent moisture from leaking under the flashings and into the structure. Endlap flashings a minimum of 6” and seal the lap joints with sealant. Extend flashings 4-6” beyond the building, cut along the bend lines, ap-
EL296UHV UPFLOW/HORIZONTAL GAS FURNACES ... - HVAC …
www.hvactechgroup.comPermanent split capacitor (PSC), heavy duty blower prepurges heat exchanger and safely vents flue products. Dual pressure switches (low fire/high fire) prove blower operation before allowing gas valve to open. Operates only during heating cycle. Flame Rollout Switches (2) Manual reset switches are factory installed on burner box.
March 2021 - Nichiha
www.nichiha.com(left) with a V-Groove joint versus TuffBlock (right) with a Split V-Groove. A) 16mm & 21mm AWP 1818 and AWP 3030 mixed on walls ten feet or less in width. AWP 3030 Wall width 10 feet or less B) 16mm & 21mm AWP 1818 and AWP 3030 together on walls wider than ten feet. 1818’s grouped on top with 3030’s below only. AWP 3030 with stacked/aligned
Technical Note - Roofs - Queensland
www.qld.gov.auvital to keep it watertight. Faulty flashings, blocked valley gutters or downpipes and rusted roof sheets can all cause leaks. Water can gain entry where loose or missing fixings have allowed side laps to lift or become distorted. Faulty joints around flues, vents, skylights and chimneys can also cause problems.