Technical Data Sheet - Jotun
NORSOK Standard M-501, Edition 6, Coating system no. 7A - Carbon and stainless steel in the splash zone NORSOK Standard M-501, Edition 6, Coating system no. 7B - Submerged carbon and stainless steel ≤ 50 °C NORSOK Standard M-501, Edition 6, Coating system no. 7C - Submerged carbon and stainless steel >50 °C Colours selected range of colours
Download Technical Data Sheet - Jotun
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Technical Data Sheet - Jotun
www.jotun.comTechnical Data Sheet Hardtop Flexi The provided data is typical for factory produced products, subject to slight variation depending on colour. Gloss description: According to …
Technical Data Sheet Application Guide
www.jotun.comEpoxy HR Product description This is a two component polyamine cured phenolic/novolac epoxy coating. It is heat resistant up to 205 °C (401 °F) and can be applied on hot substrates up to 150 °C (302 °F).
Technical Data Sheet
www.jotun.comTechnical Data Sheet Epoxy HR Surface preparation summary table Substrate Minimum Recommended Carbon steel St 2 (ISO 8501-1) Sa 2½ (ISO 8501-1) Stainless steel The surface shall be hand or machine
Technical Data Sheet Application Guide
www.jotun.comApplication Guide 3140;3240;4320 1,2 3140 Scope The Application Guide offers product details and recommended practices for the use of the product. The Application Guide (AG) must be read in conjunction with the relevant specification, Technical Data Sheet (TDS) and Safety Data Sheet (SDS) for all the products used as part of the coating system.
Technical Data Sheet - Jotun
www.jotun.comOptimum performance, including adhesion, corrosion protection, heat resistance and chemical resistance is achieved with recommended surface preparation. Date of issue:22 March 2021 Page: 3/7 This Technical Data Sheet supersedes those previously issued.
Technical Data Sheet - Jotun
www.jotun.comPackaging (typical) The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary due to local regulations. Size of containers (litres) Aluminium Paint H.R. 5 5 Storage Volume (litres) Depending on the actual exposure of the coating system, various primers and topcoats can be used in
Technical Data Sheet Jotamastic 87 Aluminium
www.jotun.comPackaging (typical) The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary due to local regulations. Size of containers Jotamastic 87 Wintergrade Comp B 4 5 (litres) Jotamastic 87 Standard Comp B 2.7 Jotamastic 87 Aluminium Comp A 14.7 20 3 Volume (litres) Date of issue:27 June 2017 Page ...
Technical Data Sheet
www.jotun.comLEED®v4 (2013) MR credit: Building product disclosure and optimization - Material Ingredients, Option 2: Material Ingredient Optimization, International Alternative Compliance Path - REACH optimization: Fully inventoried chemical ingredients to 100 …
Technical Data Sheet
www.jotun.comThis is a two component amine cured epoxy coating. It is a fast drying, zinc phosphate pigmented, high solids, high build product. Specially designed for new construction where short dry to handle and over coating times are required. Can be used as primer, mid coat, finish coat or as single coat system in atmospheric environments.
SAFETY DATA SHEET - Jotun
www.jotun.com1.3 Details of the supplier of the safety data sheet Product type :Liquid. Product description :Paint. 1.2 Relevant identified uses of the substance or mixture and uses advised against SECTION 1: Identification of the substance/mixture and of the company/ undertaking Product code :3140 1.4 Emergency telephone number SAFETY DATA SHEET
Related documents
Gas-Liquid Separators Sizing Parameter
www.jmcampbell.comSep 09, 2015 · region is NORSOK P-100. Table 1. API 12 J recommended range of KS –values for vertical and horizontal separators [7] Type Height or Length, ft (m) Typical KS range, ft/sec Typical KS range, m/s Vertical 5 (1.52) 0.12 to 0.24 0.037 – 0.073 10 (3.05) 0.18 to 0.35 0.055 – 0.107 Horizontal 10 (3.05) 0.40 to 0.50 0.122 to 0.152
ISO12944 - AkzoNobel
international.brand.akzonobel.comISO12944 is the industry standard for corrosion protection of steel structures by protective paint systems. Originally released in 1998, the standard is put together by representatives from key countries and companies involved in the protection of steel structures to build a mutually beneficial standard.
ASTM A182 F51 – Duplex Stainless Steel
www.duplexsteel.coNORSOK D41 to D45 Forging Forging temperature for this material should be 1100 – 1250oC Reheat as often as necessary and cool in still air. Machining Material in the annealed condition is readily machinable by all conventional methods. Welding F51 is readily weldable using many of the standard electric arc welding processes but oxyacetylene ...
Standards, Steel, Stainless, Duplex, Norsok, F51 duplex stainless steel
NORSOK STANDARD N-001
www.standard.noNORSOK standard N-001 Rev. 4, February 2004 NORSOK standard Page 4 of 22 NORSOK N-002 Collection of metocean data NORSOK N-003 Actions and action effects NORSOK N-004 Design of steel structures NORSOK N-005 Condition monitoring of load bearing structures NORSOK S-001 Technical safety NORSOK S-002 Working environment
NORSOK STANDARD
www.standard.noNORSOK Standard 2 of 16 FOREWORD NORSOK (The competitive standing of the Norwegian offshore sector) is the industry initiative to add value, reduce cost and lead time and remove unnecessary activities in offshore field developments and operations. The NORSOK standards are developed by the Norwegian petroleum industry as a part of the
合金 2507 スーパー・デュープレックス・ ステンレス鋼製 …