tecHnical data - Viking Corp
concentrate control valve applications, priming connections and trims tecHnical data Foam 61b May 3, 2013 the viking corporation, 210 n industrial park drive, Hastings mi 49058
Data, Technical, Foam, Technical data, Concentrate, Technical data foam
Download tecHnical data - Viking Corp
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
TECHNICAL DATA soLENoID vALvEs rATED To 250 …
www.vikingcorp.comTECHNICAL DATA June 5, 2013 Deluge 273a soLENoID vALvEs rATED To 250 psI (17.2 bAr) The viking Corporation, 210 N Industrial park Drive, Hastings MI 49058
Data, Technical, Trade, Valves, Solenoid, Technical data, Deluge, Technical data solenoid valves rated
Deluge System Technical Manual for Operation, …
www.vikingcorp.comDeluge System Technical Manual for Operation, Maintenance, and Troubleshooting. June, 2009. Form No. F_010708
Manual, Operations, System, Maintenance, Technical, Deluge, Deluge system technical manual for operation
standard response teChniCal data upright and …
www.vikingcorp.comstandard response upright and pendent sprinklers teChniCal data February 17, 2012 the Viking Corporation, 210 n industrial park drive, hastings Mi 49058
Standards, Data, Technical, Response, Technical data, Standard response technical data upright and, Upright, Standard response upright
Standard Coverage Sprinkler Quick Reference Guide
www.vikingcorp.comLight, Ordinary, and Extra Hazard Standard Response Standard Coverage Sprinkler Quick Reference Guide This guide is intended for general reference only.
Guide, Standards, Reference, Response, Quick, Coverage, Sprinkler, Standard coverage sprinkler quick reference guide, Standard response standard coverage sprinkler quick reference guide
QUICK RESPONSE TECHNICAL DATA DRY …
www.vikingcorp.comQUICK RESPONSE TECHNICAL DATA DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI …
Data, Technical, Response, Quick, Pendent, Quick response technical data dry, Quick response technical data dry pendent
SOLID CONE TECHNICAL DATA SPRAY NOZZLES - …
www.vikingcorp.comSOLID CONE SPRAY NOZZLES TECHNICAL DATA are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of
Data, Viking, Technical, Solid, Spray, Nozzle, Cone, Solid cone technical data spray nozzles, Solid cone spray nozzles technical data, Viking technical data
AWWA C110, ANSI A21.10 UNITED BRAND FITTINGS
www.vikingcorp.comUNITED CLASS 250 FLANGED FITTINGS AWWA C110, ANSI A21.10 Tel: 800-807-2215 Fax: 800-807-2214 Email: sales@napacinc.com Website: www.napacinc.com
United, Fitting, Flanged, Brand, Flanged fittings, United brand fittings
TECHNICAL DATA DELUGE SYSTEM - vikingcorp.com
www.vikingcorp.comTECHNICAL DATA April 17, 2009 DELUGE SYSTEM The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
System, Data, Technical, Technical data, Deluge, Technical data deluge system, Deluge system
quick response technical data dry horizontal …
www.vikingcorp.comquick response dry horizontal sidewall sprinklers technical data February 26, 2014 the Viking corporation, 210 n industrial park drive, hastings Mi 49058
Data, Technical, Response, Quick, Horizontal, Technical data, Quick response, Quick response technical data dry horizontal
Spray Nozzles Selection for Water Spray Systems
www.vikingcorp.comSpray Nozzles Selection for Water Spray Systems Scott Martorano, CFPS, Senior Manager Technical Service March 2007 Technical Article
Selection, Water, Spray, Nozzle, Spray nozzles selection for water spray
Related documents
03 Foam Proportioning Equipment - Buckeye Fire Equipment
buckeyefire.com54 The same system covering the same 1,500 sq. ft. with the same application rate but the foam concentrate of choice is 3% AR-AFFF. The flow range of the ILBP unit
Foam, Equipment, Concentrate, 03 foam proportioning equipment, Proportioning, Afff, Foam concentrate
MATERIAL SAFETY DATA SHEET - Certification
www.bisonfire.comAFFF 3% FOAM CONCENTRATE (PN#04426) MSDS Page 3 of 13 ACUTE: This product may be mildly to moderately irritating to the skin or via inhalation, depending on concentration and duration of exposure. Eye contact will immediately irritate the eyes, with pain, tearing and redness.
Sheet, Data, Safety, Material, Foam, Material safety data sheet, Concentrate, F3 ffa, Afff, Foam concentrate
01 General Foam Information - chemguard.com
www.chemguard.comCHEMGUARD 204 S. 6th Ave • Mansfield, Tx 76063 • (817) 473-9964 • FAX (817) 473-0606 www.chemguard.com DATA SHEET #D10D03010 REVISION: 09/2005 AR-AFFF 3%-6% type of concentrate is designed to be used at the 3% application rate when used on a standard hydrocarbon fuel fire and 6% when
Balanced Pressure Proportioner PPW MK2 - SKUM
www.skum.comDATA SHEET Balanced Pressure Proportioner PPW MK2 General Description An accurate proportioner for foam concentrate is vital for the correct performance of a foam system, irrespective of
Pressure, Balanced, Foam, Concentrate, Balanced pressure proportioner ppw mk2, Proportioner, Foam concentrate, A foam
AFFF Fluorine Facts Show FTS - combatsupportproducts.com
www.combatsupportproducts.comsugar. Half cup alcohol based class A foam or regular AFFF and a shot glass of AR-AFFF can do this in minutes.! The AR-AFFF’s polymer is doing
Phase I Final Rule and Technical Development Document of ...
www.epa.gov10 3.1 Locality The Navy provides instruction on where seawater AFFF solutions can be discharged during maintenance that tests the proportioning accuracy of AFFF proportioning stations.
SAFETY DATA SHEET BUCKEYE PLATINUM 6% AFFF
www.buckeyefire.comSAFETY DATA SHEET BUCKEYE PLATINUM 6% AFFF Buckeye Fire Equipment Page 2 of 4 Inhalation- Move victim to fresh air.Trained personnel may provide oxygen if breathing is difficult.
Sheet, Data, Safety, Platinum, Buckeye, Afff, Safety data sheet buckeye platinum 6 afff
Request for Foam Analysis - chemguard.com
www.chemguard.comCheck here if a proportioning test is required. Send 1 qt. (1L) of system water and 8 oz. (250 ml) of foam concentrate in addition to the proportioned (premixed)