WATERPROOFING SYSTEMS - Henry
Secondary Containment Structures • Tunnels • Underground ... Drainage & Irrigation Channels • Potable Water Reserves • Seals Embedded Steel, PVC or HDPE Pipe Penetrations HENRY DRAINAGE COMPOSITES: A BETTER ENGINEERED SOLUTION FOR MANAGING THE FLOW OF WATER ... highway drainage systems.
Download WATERPROOFING SYSTEMS - Henry
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
HE784 - AQUA-BLOC® WB - henry.com
henry.comLimited Warranty We, the manufacturer, warrant only that this product is free of defects, since many factors which affect the results obtained from this product - such as weather, workmanship, equipment utilized and prior condition of the substrate - are
TECHNICAL DATA SHEET
henry.comREVISION: 11/17/15 Henry Company, 999 N. Sepulveda Blvd., Ste. 800, El Segundo, CA 90245 Technical Services - Phone: (800) 486-1278 – Email: techservices@henry.com www.henry.com Henry CM100 Fast Curing, Elastomeric Fluid Membrane Uses Henry CM100 may be used as a waterproofing and roofing membrane on horizontal or vertical surfaces. Ideal alternative to hot
TECHNICAL DATA SHEET - Henry
henry.comImpermeable to air, moisture vapor and water Compatible with Henry® Air-Bloc fluid applied air barriers Self-gasketing when penetrated and under compression with self-tapping screws Usage Blueskin SA is designed for use as a self-adhered air, vapor and water resistive barrier. It can also be used as a transition sheet
Sheet, Data, Technical, Barriers, Water, Technical data sheet, Resistive, Air barrier, Water resistive
Henry Blueskin VP160 Air Barrier System Installation Manual
henry.com3 1. Introduction This installation manual includes materials and installation procedures for Henry® Blueskin® VP160 Self-Adhered Water Resistive Air Barrier system. Blueskin® VP160 meets the current IBC and IECC air barrier requirements for a water resistive barrier (WRB) as referenced in ICC ESR-2975.
Installation, Water, Resistive, Water resistive, Water resistive air
TECHNICAL DATA SHEET - Henry
henry.comAir Permeance - Material @1.57psf (75Pa) 0.0001 cfm/ft² (0.0005 L/[sec-m²]) ASTM E2178 Air Leakage - Assembly Pass ASTM E2357 Elongation 250% ASTM D412 Tensile Strength 140 psi (965 kPa) ASTM D412 Flame Spread Index 10, Class A ASTM E84 Smoke Developed 15, Class A ASTM E84 Fire Testing Complies with NFPA 285 in various wall
Sheet, Data, Testing, Technical, Technical data sheet, Leakage, Air leakage
Henry 925 BES Sealant
henry.comHenry® 925 BES Sealant is a premium, moisture cure sealant for construction joints subject to dynamic joint movement. This one-part, low odor, moisture cure product provides excellent weathering resistance, flexibility, very low VOC, through use of a silyl-terminated polyether (STPE) polymer. Upon curing, it is paintable with latex based paints.
TECHNICAL DATA SHEET - Henry
henry.comcast-in-place concrete, concrete block, steel, aluminum and galvanized metal. Strike masonry joints full-flush. Concrete surfaces must be smooth and without large voids, spalled areas or sharp protrusions. Concrete must be cured a minimum of 14 days. Curing
Sheet, Data, Technical, Steel, Technical data sheet, Galvanized
Air-Bloc All Weather STPE
henry.comHenry® Air-Bloc All-Weather STPE is a low VOC, UV and fire-resistant fluid applied, elastomeric membrane designed to provide a vapor permeable, water resistive air barrier when applied to above-grade wall assemblies. It is single-component, moisture cure
Water, Step, Weather, Resistive, Water resistive air, All weather stpe
TECHNICAL DATA SHEET Blueskin WP200 - Henry
henry.comREVISION: 02/27/17 Henry Company 999 N. Sepulveda, Ste 800, El Segundo CA 90245-2754 Technical Services- Phone (800) 486-1278 – Email: techservices@henry.com www.henry.com Blueskin WP 200 Self-Adhesive Waterproofing Membrane Uses Blueskin WP200 is designed for use as a self-adhered s heet waterproofing membrane in above or below grade applications.
Sheet, Data, Data sheet, Heet, Sh eet
Air & Water Barrier Membrane - Henry
henry.comConcrete . ASTM C836 load suction pressure-Low Temperature Flexibility and Crack Bridging @ –20°C . ASTM C836 -Aging-Long Term Flexibility . CGSB 71 -GP-24M -Nail Sealability . ASTM D1970 --Resistance to Mold, Mildew & Fungal growth . ASTM D5590 . ASTM E84-VOC Content . Gray . 60% . 10.8 lbs/gal (1.3 kg/l) 2 Hours to touch dry . 24 Hours to ...
Related documents
10. Standards for materials used in plumbing systems
www.who.intof such systems overall, the material is not desirable for internal water plumbing. Galvanized pipe is heavy to handle and is generally joined by threading and screwing the components together. This is a lengthy procedure when compared to the assembly of competing non-metallic pipework systems. 10.3.2 Copper tubing
Terrain Drainage Systems - Polypipe
www.polypipe.comA Guide to the Terrain PVC Drainage Numbering System Above Ground Drainage Series 100 = PVCu Solvent Weld Soil 100P = PVCu Push Fit Soil 200 = MuPVC Solvent Weld Waste 300 = PP Push Fit Waste 400 = Traps 500 = PVCu Overflow 900 = FUZE Diameter 3 = 3” or 82mm O/D soil 4 = 4” or 110mm O/D soil 6 = 6” or 160mm O/D soil 8 = 8” or 200mm O/D soil
System, Terrain, Drainage, Terrain drainage systems, Pvc drainage
SUBMITTAL FOR CHARLOTTE PIPE PVC SDR 35 GRAVITY …
www.charlottepipe.comapplications with a pipe stiffness of 46. This systems is intended for gravity applications where the operating temperature will not exceed 140°F. Specification: Pipe shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a …
System, Charlotte, Pipe, Chloride, Polyvinyl, Submittal, Polyvinyl chloride, Submittal for charlotte pipe pvc
RAINWATER CALCULATIONS - Hunter Plastics
www.hunterplastics.co.uk98 Compatibility Table Rainwater Waste Soil Underground Half Round Squareflo 125 110mm Push-fit Solvent 110mm 160mm Hepworth Marley Osma Polypipe Brett RAINWATER CALCULATIONS Hunter products are compatible with many other manufacturers’ systems and with traditional cast iron and aluminium systems.