282906-BTG-D-0109 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALESINGLE PACKAGE GAS/ELECTRIC UNITSAND SINGLE PACKAGEAIR CONDITIONERSDW-03, -04 & -053, 4 & 5 NOMINAL to SEER DESCRIPTIONUP units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4 and 5 ton sizes. The units were designed for light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or units include: Powder Paint finish that meets ASTM-B-117 1000 hour salt spray standards Permanently lubricated motors Bottom or side air discharge configuration capability (field convertible) Manufactured under the quality standards of ISO9001 Simplicity Control Board Copper tube/aluminum fin coils Easy access to all components Rigging holes in base rails for lifting Fork lift slots on three sides Single point power connection Complete factory package - tested, charged and wired CSA agency listing on all unitsWARRANTY Factory Limited Parts Warranty One-year parts warranty A Five-year parts warranty on the compressor andelectric heat elements.

282906-BTG-D-0109 Johnson Controls Unitary Products 3 PRODUCT NOMENCLATURE D W -04 N07 A T A AA 2 0 1 2 4 A D = A/C, Single Pkg., R-22 Product Category

Tags:

  Dw 03, Amp 05

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of B-TG, SP G/E SPAC, Models: DW-03, -04, & -05, 3, …

1 282906-BTG-D-0109 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALESINGLE PACKAGE GAS/ELECTRIC UNITSAND SINGLE PACKAGEAIR CONDITIONERSDW-03, -04 & -053, 4 & 5 NOMINAL to SEER DESCRIPTIONUP units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4 and 5 ton sizes. The units were designed for light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or units include: Powder Paint finish that meets ASTM-B-117 1000 hour salt spray standards Permanently lubricated motors Bottom or side air discharge configuration capability (field convertible) Manufactured under the quality standards of ISO9001 Simplicity Control Board Copper tube/aluminum fin coils Easy access to all components Rigging holes in base rails for lifting Fork lift slots on three sides Single point power connection Complete factory package - tested, charged and wired CSA agency listing on all unitsWARRANTY Factory Limited Parts Warranty One-year parts warranty A Five-year parts warranty on the compressor andelectric heat elements.

2 Ten-year parts warranty on the gas-fired Controls Unitary ProductsTABLE OF CONTENTSDESCRIPTION .. 1 PRODUCT NOMENCLATURE .. 3 FEATURES .. 4 FACTORY-INSTALLED OPTIONS .. 6 FIELD-INSTALLED ACCESSORIES .. 7 GUIDE SPECIFICATIONS .. 43 LIST OF FIGURESFig. #Pg. #1 UNIT CUTAWAY .. 52 TYPICAL FIELD POWER & CONTROL WIRING .. 363 UNIT DIMENSIONS (3 - 5 TON COOLING ONLY/ELECTRIC HEAT) FRONT VIEW .. 374 UNIT DIMENSIONS (3 - 5 TON COOLING/GAS HEAT) FRONT VIEW .. 375 UNIT WITH ECONOMIZER RAINHOOD .. 386 UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD .. 387 UNIT DIMENSIONS (REAR VIEW) .. 398 DISCONNECT/BLOWER ACCESS LOCATION .. 399 TYPICAL APPLICATIONS .. 4010 FOUR AND SIX POINT LOADING .. 4111 ROOF CURB DIMENSIONS.

3 42 LIST OF TABLESTbl. #Pg. #1 CAPACITY RATINGS - (ARI 210/240) .. 82 GAS HEAT RATINGS .. 83 2 STAGE GAS HEAT RATINGS .. 84 DW-03 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) .. 95 DW-03 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) .. 96 DW-03 INDOOR SOUND POWER LEVELS(VERTICAL DUCTED INLET) .. 107 DW-03 INDOOR SOUND POWER LEVELS(VERTICAL DUCTED DISCHARGE) .. 108 DW-04 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) .. 119 DW-04 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) .. 1110 DW-04 INDOOR SOUND POWER LEVELS(VERTICAL DUCTED INLET) .. 1211 DW-04 INDOOR SOUND POWER LEVELS(VERTICAL DUCTED DISCHARGE) .. 1212 DW-05 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) .. 1313 DW-05 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE).

4 1314 DW-05 INDOOR SOUND POWER LEVELS(VERTICAL DUCTED INLET) .. 14 Tbl. #Pg. #15 DW-05 INDOOR SOUND POWER LEVELS(VERTICAL DUCTED DISCHARGE) .. 1416 DW-03 COOLING CAPACITIES (3 TON) .. 1517 DW-04 COOLING CAPACITIES (4 TON) .. 1618 DW-05 COOLING CAPACITIES (5 TON) .. 1719 SUPPLY AIR BLOWER PERFORMANCE (DW-03 BELT DRIVE) - SIDE DUCT APPLICATION .. 1820 SUPPLY AIR BLOWER PERFORMANCE (DW-03 BELT DRIVE) - BOTTOM DUCT APPLICATION .. 1821 SUPPLY AIR BLOWER PERFORMANCE (DW-04 BELT DRIVE) - SIDE DUCT APPLICATION .. 1822 SUPPLY AIR BLOWER PERFORMANCE (DW-04 BELT DRIVE) - BOTTOM DUCT APPLICATION .. 1923 SUPPLY AIR BLOWER PERFORMANCE (DW-05 BELT DRIVE) - SIDE DUCT APPLICATION .. 1924 SUPPLY AIR BLOWER PERFORMANCE (DW-05 BELT DRIVE) - BOTTOM DUCT APPLICATION.

5 1925 SUPPLY AIR BLOWER PERFORMANCE(DW-03, -04, & -05 DIRECT DRIVE) SIDE DUCT APPLICATION .. 2026 SUPPLY AIR BLOWER PERFORMANCE(DW-03, -04, & -05 DIRECT DRIVE) BOTTOM DUCT APPLICATION .. 2027 BELT DRIVE RPM SELECTION .. 2028 BELT DRIVE BLOWER MOTOR AND DRIVE DATA.. 2129 STATIC RESISTANCES .. 2130 ELECTRIC HEAT CFM LIMITATIONS .. 2231 ELECTRICAL DATA - DW-03, -04 & -05 DIRECT DRIVE W/O POWERED CONVENIENCE OUTLET .. 2332 ELECTRICAL DATA - DW-03, -04 & -05 BELT DRIVEW/O POWERED CONVENIENCE OUTLET .. 2533 ELECTRICAL DATA - DW-03, -04 & -05 BELT DRIVE HIGH STATIC W/O POWERED CONVENIENCEOUTLET .. 2734 ELECTRICAL DATA - DW-03, -04 & -05 DIRECT DRIVE W/POWERED CONVENIENCE OUTLET .. 2935 ELECTRICAL DATA - DW-03, -04 & -05 BELT DRIVE WITH POWERED CONVENIENCE OUTLET.

6 3136 ELECTRICAL DATA - DW-03, -04 & -05 BELT DRIVE HIGH STATIC WITH POWERED CONVENIENCE OUTLET .. 3337 DW PHYSICAL DATA .. 3538 ELECTRIC HEAT CORRECTION FACTORS .. 3539 VOLTAGE LIMITATIONS .. 3540 UTILITIES ENTRY .. 3941 MINIMUM CLEARANCES .. 3942 DW 4 AND 6 POINT LOADS WEIGHTDISTRIBUTION .. 4143 CENTER OF GRAVITY .. 4144 OPERATING WEIGHTS (LBS.) .. 42282906-BTG-D-0109 Johnson Controls Unitary Products3 PRODUCT NOMENCLATURED W -04N07 ATAAA20124AD = A/C, Single Pkg., R-22 Product CategoryAirflowProduct Generation2 = Second GenerationC00 = Cooling Only. Suitable for Field Installed Electric HeatHeat Type and Nominal Heat CapacityN05 = 50 MBH Input Aluminized Steel, 1 Stage (-03)N07 = 75 MBH Input Aluminized Steel, 1 Stage (-04)N11 = 100 MBH Input Aluminized Steel, 1 Stage(-03, -05)N13 = 125 MBH Input Aluminized Steel, 1 Stage( -04, -05)D07 = 75 MBH Input Aluminized Steel, 2 Stage(-03, -04, -05)S05 = 50 MBH Input Stainless Steel, 1 Stage (-03)T07 = 75 MBH Input Stainless Steel, 2 Stage(-03, -04, -05)S07 = 75 MBH Input Stainless Steel, 1 Stage (-04)D13 = 125 MBH Input Aluminized Steel, 2 Stage(-03*, -04, -05)T13 = 125 MBH Input Stainless Steel, 2 Stage(-03*, -04, -05)S11 = 100 MBH Input Stainless Steel, 1 Stage(-03, -05)S13 = 125 MBH Input Stainless Steel, 1 Stage(-04, -05)

7 E05 = 5 KWE07 = 7 KWE10 = 10 KWE15 = 15 KW E20 = 20 KW E30 = 30 KW Gas Heat OptionsElectric Heat Options-03 = TonNominal Cooling Capacity-04 = Ton-05 = TonProduct IdentifierW = SEER A/CVoltageF = 208/230-1-60T = 208/230-3-60W = 460-3-60X = 575-3-60 Product StyleA = Style AA = No Options InstalledInstallation OptionsB = Option 1C = Option 2D = Options 1 & 2E = Option 3F = Option 4G = Options 1 & 3H = Options 1 & 4J = Options 1, 2 & 3K = Options 1, 2, & 4L = Options 1,3 & 4M = Options 1, 2, 3, & 4N = Options 2 & 3P = Options 2 & 4Q = Options 2, 3, & 4R = Options 3 & 4S = Option 5T = Options 1 & 5U = Options 1, 3, & 5V = Options 1, 4, & 5W = Options 1, 3, 4, & 5X = Options 3 & 5Y = Options 4 & 5Z = Options 3, 4 & 51 = Disconnect2 = Non-Pwr'd Conv. Outlet3 = Smoke Detector = Smoke Detector = Pwr'd Conv.

8 OutletOptionsSS Drain PanConfiguration Options (not required for all units)These four digits will not be assigned until a quote is requested, or an order Controller, DFS, APSJ ohnson Controller, DFS, APSH oneywell Controller, DFS, APSN ovar Controller, DFS, APSS implicity IntelliComfort ControllerSimplicity IntelliComfort Controller w/ModLinc2" Pleated filtersBAS Ready Economizer (2-10 Actuator Without a Controller)Any Combination of Additional Options that Don t Have an Option Code Pre-assigned AA = NoneStandard CabinetAB = Phase MonitorAC = Coil GuardAD = Dirty Filter SwitchAE = Phase Monitor & Coil GuardAF = Phase Monitor & Dirty Filter SwitchAG = Coil Guard & Dirty Filter SwitchAH = Phase Monitor, Coil Guard & Dirty Filter SwitchAS = Bottom Drain ConnectionRC = Coil Guard & American FlagTA = Technicoat Condenser CoilTJ = Technicoat Evaporator CoilTS = Technicoat Evaporator and Condenser CoilAdditional OptionsHinged Filter Door & Toolless Access Cabinet3-5 Ton Model Number NomenclatureBA = Hinged Filter Door & Toolless Access PanelsBB = Phase Monitor, Hinged Filter Door & ToollessAccess PanelsBC = Coil Guard.

9 Hinged Filter Door & ToollessAccess PanelsBD = Dirty Filter Switch, Hinged Filter Door &Toolless Access PanelsBE = Phase Monitor & Coil Guard, Hinged FilterDoor & Toolless Access PanelsBF = Phase Monitor & Dirty Filter Switch, HingedFilter Door & Toolless Access PanelsBG = Coil Guard & Dirty Filter Switch, Hinged FilterDoor & Toolless Access PanelsBH = Phase Monitor, Coil Guard & Dirty Filter Switch,Hinged Filter Door & Toolless Access PanelsZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will belocated in digits 15-18. * (D, T) 13 = 115 MBH Input on -03 Models N = Belt DriveD = Direct Drive/Motorized DamperB = Direct Drive/EconomizerA = Direct DriveP = Belt Drive/EconomizerR = Belt Drive/Motorized DamperT = Belt Drive High Static U = Belt Drive High Static/EconomizerV = Belt Drive High Static/Motorized Damper282906-BTG-D-01094 Johnson Controls Unitary ProductsFEATURESAll models are available with a wide variety of factory-mounted options such as stainless steel heat exchangers, electric heaters, phase monitor, convenience outlet, dirty filter switch, disconnect switch, smoke detectors, and coil guard to make them suitable for almost every units are self-contained and assembled on full perimeter base rails with forklift holes on three sides and holes for over-head rigging.

10 Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable models (including those with an economizer) are suitable for either bottom or horizontal duct connections. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizon-tal duct, remove the supply and return air panels on the rear of the models are available with these factory mounted outdoor air damper options: Single enthalpy economizer Motorized outdoor air damperSupply air blowers are equipped with either a direct drive or belt drive that can be adjusted to meet the exact require-ments of the compressors are equipped with internal pressure relief.