Example: barber

Material Safety Data Sheet - Quality Chemical …

Wash with a disinfectant soap and cover the contaminated skin with an anti-bacterial cream. Seekimmediate medical additional for and remove any contact lenses. IMMEDIATELY flush eyes with running water for at least 15minutes, keeping eyelids open. COLD water may be used. DO NOT use an eye ointment. Seekmedical the victim to rest in a well ventilated area. Seek immediate medical the victim to a safe area as soon as possible. Loosen tight clothing such as a collar, tie, belt orwaistband. If breathing is difficult, administer oxygen. If the victim is not breathing, performmouth-to-mouth resuscitation. WARNING: It may be hazardous to the person providing aid to givemouth-to-mouth resuscitation when the inhaled Material is toxic, infectious or corrosive. Seek immediatemedical swallowed, do not induce vomiting unless directed to do so by medical personnel.

Wash with a disinfectant soap and cover the contaminated skin with an anti-bacterial cream. Seek immediate medical attention. No additional information.

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Material Safety Data Sheet - Quality Chemical …

1 Wash with a disinfectant soap and cover the contaminated skin with an anti-bacterial cream. Seekimmediate medical additional for and remove any contact lenses. IMMEDIATELY flush eyes with running water for at least 15minutes, keeping eyelids open. COLD water may be used. DO NOT use an eye ointment. Seekmedical the victim to rest in a well ventilated area. Seek immediate medical the victim to a safe area as soon as possible. Loosen tight clothing such as a collar, tie, belt orwaistband. If breathing is difficult, administer oxygen. If the victim is not breathing, performmouth-to-mouth resuscitation. WARNING: It may be hazardous to the person providing aid to givemouth-to-mouth resuscitation when the inhaled Material is toxic, infectious or corrosive. Seek immediatemedical swallowed, do not induce vomiting unless directed to do so by medical personnel.

2 Never give anythingby mouth to an unconscious person. Loosen tight clothing such as a collar, tie, belt or waistband. Getmedical attention Safety Data SheetMaterial usesMURIATIC ACIDI ndustrial applications: Powerful acid forcleaning and contactSkin contactHazardousinhalationSlight inhalationSlight ingestionHazardous ingestionIn case of contact, immediately flush skin with plenty of water for at least 15 minutes while removingcontaminated clothing and shoes. Cover the irritated skin with an emollient. Cold water may be clothing before reuse. Thoroughly clean shoes before reuse. Get medical attention immediately. 8 WHMISTDG Road/RailSection IA. First Aid MeasuresSection I. Product Identification and UsesHazardous skincontact30-10000 SupplierManufacturerSANI-MARC boul. de l'Artisan,Victoriaville, Qc (819) 758-1541 SANI-MARC boul. de l'Artisan,Victoriaville, Qc (819) 758-1541 CodeTrade nameProtective Clothing301 JHealth HazardFire HazardReactivityPersonal Protection*Governmental ApprobationsNot II.

3 Hazardous Ingredientspage 2/4 MURIATIC ACIDH ydrochloric acid7647-01-030-60 TWA: 5 (ppm) fromACGIHORAL (LD50): Acute: 900mg/kg [Rabbit]. GAS(LC50): Acute: 1562 ppm 4hour(s) [Rat]. 757 ppm 4hour(s) [Mouse].NameCAS #TLV/PEL% by WeightLC50/LD50 Physical state and appearanceVolatilitypH (1% soln/water)OdorColorFreezing pointBoiling/Condensation pointVapor pressureOdor thresholdSpecific gravityVapor densityWater/oil dist. (surface active agent)Dispersion propertiesSolubilityLiquid. (Transparent liquid)Not (Conc. (% w/w): 1) [Acidic.] C (-40 F)98 C ( F) (Water = 1) (Air = 1)20 mm of Hg (@ 20 C)The product is equally soluble in oil and solubility in water, methanol, soluble in cold water, hot water, methanol, (Strong.)The highest known value is 1 ppm (Hydrochloric acid)Critical temperatureNot temperatureNot of instabilityNo additional III.

4 Physical DataViscosityEvaporation rateNot (Pure) [Acid.]Hazardous ofdegradationReactivityThe product is:Auto-ignition temperatureFire degradationproductsFlash pointsFire extinguishingproceduresFlammable limitsFlammabilityDegradabilityNot product is hazardous short term degradation products are not likely. However, long term degradation products may products of degradation are as toxic as the original specific information is available in our database regarding the corrosivity of this product in presenceof various reactive with metals, with reducing of explosionRisks of explosion of the product in presence of mechanical impact: Not of explosion of the product in presence of static discharge: Not explosive in presence of oxidizing materials, of organic IV. Fire and Explosion DataSection V. Reactivity Datapage 3/4 MURIATIC ACIDNot for animalsAcute effects onhumansRoutes of entryChronic effects onhumansAbsorbed through skin.

5 Eye contact. Inhalation. oral toxicity (LD50): 900 mg/kg [Rabbit].Acute toxicity of the gas (LC50): 757 ppm 4 hour(s) [Mouse].Very hazardous in case of skin contact (corrosive, irritant, sensitizer, permeator), of eye contact (irritant, corrosive), ofingestion, of inhalation (lung irritant, lung sensitizer, lung corrosive). Liquid or spray mist may produce tissue damageparticularly on mucous membranes of eyes, mouth and respiratory tract. Skin contact may produce burns. Inhalationof the spray mist may produce severe irritation of respiratory tract, characterized by coughing, choking, or shortnessof breath. Severe over-exposure can result in death. Inflammation of the eye is characterized by redness, watering,and itching. Skin inflammation is characterized by itching, scaling, reddening, or, occasionally, hazardous in case of skin contact (corrosive, irritant, sensitizer, permeator), of eye contact (irritant), of ingestion, of inhalation (lung irritant, lung sensitizer).

6 CARCINOGENIC EFFECTS: Not EFFECTS: Not EFFECTS: Not TOXICITY: Not (United States). TWA: 5 ppmConsult local authorities for acceptable exposure VI. Toxicological Properties 8 StoragePrecautionsSmall spill and leakLarge spill and leakProtective clothingCorrosive materials should be stored in a separate Safety storage cabinet or with water and mop up, or absorb with an inert DRY Material and place in an appropriate waste disposalcontainer. If necessary: Neutralize the residue with a dilute solution of sodium leak if without risk. Absorb with DRY earth, sand or other non-combustible Material . Do not get waterinside container. Do not touch spilled Material . Use water spray curtain to divert vapor drift. Use water sprayto reduce vapors. Prevent entry into sewers, basements or confined areas; dike if needed. Call for assistanceon disposal.

7 Neutralize the residue with a dilute solution of sodium goggles. Full suit. Vapor and dust respirator. Boots. Gloves. A self contained breathingapparatus should be used to avoid inhalation of the locked up. Keep container dry. DO NOT ingest. Do not breathe gas, fumes, vapor or spray. Never add water to this case of insufficient ventilation, wear suitable respiratory equipment. If ingested, seek medical advice immediately and show thecontainer or the label. Avoid contact with skin and eyes. Keep away from incompatibles such as reducing agents, metals, VII. Preventive Measurespage 4/4 MURIATIC ACIDS plash goggles. Synthetic apron. Vapor and dust respirator. Be sure to usea MSHA approved respirator or equivalent. Gloves (impervious). Wearappropriate respirator when ventilation is Class 8: Corrosive CLASS D-1A: Material causing immediate and serious toxic effects (VERY TOXIC).

8 WHMIS CLASS E: Corrosive name: HYDROCHLORIC ACID, 8, UN 1789 PG II (Ltd. Qty. Index, 1L)TDG road / railSection VIII. ClassificationSection IX. Protective MeasuresEngineeringcontrolsProvide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below theirrespective threshold limit value. Ensure that eyewash stations and Safety showers are proximal to the clothingReferencesNot by Service Sant et S curit on 09/06 by Service Sant et S curit .Section X. Other InformationPrinted 09/06 phone: CANUTEC (613) 996-6666 (Collect calls accepted)No additional the best of our knowledge, the information contained herein is accurate. However, neither the above named supplier nor any of its subsidiaries assumes any liability whatsoever for the accuracy or completeness of theinformation contained herein.

9 Final determination of suitability of any Material is the sole responsibility of the user. All materials may present unknown hazards and should be used with caution. Although certain hazards aredescribed herein, we cannot guarantee that these are the only hazards that andprovincialregulationsNo products were informationWaste stream


Related search queries