Martens Closed Cup
Found 9 free book(s)Flash points of aqueous solutions of flammable solvents
www.icheme.orgMartens Closed Cup Flash Point Tester supplied by Gallenkamp. The procedure used was similar to that described in the relevant British3, American4 and European5 Standards. However, as the standard Pensky-Martens Closed Cup Flash Point Tester is designed for single components only, a modified procedure was used.
MONOETHYLENE GLYCOL (MEG) (Monoethylene Glycol / …
www.meglobal.bizJun 07, 2013 · Flash Point, Closed Cup (Pensky-Martens Closed Cup ASTM D93) 126.7°C 260°F Flash Point, Open Cup (Cleveland Open Cup ASTM D92) 137.8°C 280°F Heat of Combustion at 25°C -1,053 kJ/gmol -7,297 Btu/lb Heat of Formation at 25°C -460 kJ/gmol -3,188 Btu/lb Heat of Fusion 9.96 kJ/gmol 69 Btu/lb
USED OIL MATERIAL SAFETY DATA SHEET
ehs.cranesville.comFLASH POINT: >200°F (93°C) (minimum) Pensky-Martens Closed Cup FLAMMABLE LIMITS IN AIR: Not available. AUTOIGNITION TEMPERATURE: Not available. HAZARDOUS COMBUSTION Decomposition and combustion materials may be toxic. PRODUCTS: Burning may produce phosgene gas, nitrogen oxides, carbon monoxide, and unidentified organic …
Waste Characteristic Hazardous Waste D List w 1. 2. 3.
ehs.oregonstate.eduIs a liquid and has a flash point of less than 140oF (as determined by a Pensky‐Martens closed cup tester using ASTM method D‐93‐70 or D‐93‐80) 2. Is a solid and which, under under standard temperature and pressure, that can cause fire through friction, absorption of moisture, or spontaneous chemical changes and burn ...
SAFETY DATA SHEET EC1317A CORROSION INHIBITOR
irp-cdn.multiscreensite.comMethod: ASTM D 93, Pensky-Martens closed cup pH : 3.4, 100 % Odour Threshold : no data available Melting point/freezing point : POUR POINT: -46 °C Initial boiling point and boiling range : no data available Evaporation rate : no data available Flammability (solid, gas) : no data available
Material Safety Data Sheet Page 1 of 2
www.mastercleaningsupply.comFlash Point / Method: 129ºF / Pensky Martens Closed Cup Flammable Limits: Not established Extinguishing Media: Use water, foam, dry chemical, or carbon dioxide. Special Fire Fighting Procedures: Wear self-contained breathing apparatus and protective clothing in accordance with OSHA regulations. Fire and Explosion Hazards:
Flash Point Testing Explained - Stanhope-Seta
www.stanhope-seta.co.ukClosed Cup (CC) Abel, Abel-Pensky, Pensky-Martens, Tag, Setaflash (CC) Closed cup tests aim to simulate the situation of a liquid spill in a closed environment. If the liquid is at, or above, its flash point then a fire or explosion is a possibility when exposed to a potential ignition. In closed cup tests the sample is placed inside a sealed
MATERIAL SAFETY DATA SHEET - Procter & Gamble
www.pg.comPensky-Martens (Closed cup). However, the detergents do not sustain combustion according to ASTM D4206. Flammable Properties: Upper Flammable Limit: N/A Lower Flammable Limit: N/A Explosive Limits: UEL: N/A LEL: N/A Auto-ignition Temperature: N/A …
MATERIAL SAFETY DATA SHEET
www.physics.purdue.eduPensky-Martens (Closed cup). However, the detergents do not sustain combustion according to ASTM D4206. Flammable Properties: Upper Flammable Limit: N/A Lower Flammable Limit: N/A Explosive Limits: UEL: N/A LEL: N/A Auto-ignition Temperature: N/A …