Search results with tag "Closed cup"
Flash Point Testing Explained - Stanhope-Seta
www.stanhope-seta.co.ukClosed Cup (CC) Abel, Abel-Pensky, Pensky-Martens, Tag, Setaflash (CC) Closed cup tests aim to simulate the situation of a liquid spill in a closed environment. If the liquid is at, or above, its flash point then a fire or explosion is a possibility when exposed to a potential ignition. In closed cup tests the sample is placed inside a sealed
MONOETHYLENE GLYCOL (MEG) (Monoethylene Glycol / …
www.meglobal.bizJun 07, 2013 · Flash Point, Closed Cup (Pensky-Martens Closed Cup ASTM D93) 126.7°C 260°F Flash Point, Open Cup (Cleveland Open Cup ASTM D92) 137.8°C 280°F Heat of Combustion at 25°C -1,053 kJ/gmol -7,297 Btu/lb Heat of Formation at 25°C -460 kJ/gmol -3,188 Btu/lb Heat of Fusion 9.96 kJ/gmol 69 Btu/lb
APM-00-015 apm-8 Pensky-Martens Closed Cup Flash Point …
www.tanaka-sci.comThe cup cover and the stirrer are permanently mounted on a swing-arm assembly, which allows an easy handling of the test cup cover. It makes free from handling the hot cup cover after completing a test.
SAFETY DATA SHEET: NONYL PHENOL 9
www.ciscochem.comMay 15, 2015 · Flash Points CLOSED CUP: 247°C (476.6°F). (Pensky-Martens.) OPE N CUP: 282°C (539.6°F) (Cleveland) Flammable Limits Not available Products of Combustion not available Fire Hazards in Presence of Various Substances Slightly flammable to flammable in presence of open flames and sparks, of heat. Non-flammable in presence of shocks.
Aviation Fuel Quality Requirements for Jointly Operated ...
www.jigonline.com• Suppression of the bias for flash point measurement between IP 170 and ASTM D56 • Addition of Test Method D93 (Procedure A) – Standard Test method for flash point measurement by Pensky-Martens close cup tester and D7236 – standard test method for flash point by small scale closed cup tester (ramp method).
SAFETY DATA SHEET
www.castrol.comClosed cup: 204°C (399.2°F) [Pensky-Martens.] Not available. Not available. Viscosity Kinematic: 121.8 mm2/s (121.8 cSt) at 40°C Kinematic: 15.8 mm2/s (15.8 cSt) at 100°C Odor threshold Not available. Partition coefficient: n-octanol/water Appearance Boiling point Not available. Lower and upper explosive (flammable) limits Not available.
MATERIAL SAFETY DATA SHEET
www.physics.purdue.eduPensky-Martens (Closed cup). However, the detergents do not sustain combustion according to ASTM D4206. Flammable Properties: Upper Flammable Limit: N/A Lower Flammable Limit: N/A Explosive Limits: UEL: N/A LEL: N/A Auto-ignition Temperature: N/A …
MATERIAL SAFETY DATA SHEET - Procter & Gamble
www.pg.comPensky-Martens (Closed cup). However, the detergents do not sustain combustion according to ASTM D4206. Flammable Properties: Upper Flammable Limit: N/A Lower Flammable Limit: N/A Explosive Limits: UEL: N/A LEL: N/A Auto-ignition Temperature: N/A …
Makes Pensky-Martens, TAG, and Abel Flash Point Testing ...
www.rofa.atSpecifications Ordering Information HFP 360 Pensky-Martens Flash Point Analyzer HFP 362 TAG Flash Point Analyzer HFP 364 Abel Flash Point Analyzer Available Test Modules Pensky-Martens, TAG Closed Cup, and Abel Pensky-Martens (ASTM D 93, Methods A & B,