Table of Contents - Mike Holt Enterprises
www.neccode.comTable of Contents vi Mike Holt’s Illustrated Guide to Changes to the NEC 2011 210.12 Arc-Fault Circuit-Interrupter Protection for Dwelling Units ..... 47
SWIMMING POOLS, SPAS, ARTICLE HOT TUBS, FOUNTAINS, …
www.mikeholt.comMike Holt Enterprises • www.MikeHolt.com • 888.NEC.CODE (632.2633) 261 Swimming Pools, Spas, Hot Tubs, Fountains, and Similar Installations | 680.9 Author’s Comment: n This rule doesn’t prohibit utility-owned overhead service- drop conductors from being installed over a permanently installed pool, storable pool, outdoor spa, outdoor hot ...
110 RC Requirements for Electrical Installations
www.mikeholt.comMike Holt Enterprises, Inc. • www.MikeHolt.com • 888.NEC.CODE (632.2633) 11 Author’s Comments: • According to UL Standard 486 A-B, a terminal/lug/connector
1 Basic Principles of - Mike Holt Enterprises
www.mikeholt.com4 Mike Holt’s Illustrated Guide to Understanding Basic Motor Controls Unit 1 Basic Principles of Motor Controls device will operate to open the circuit because of the ...
ARTICLE 90 INTRODUCTION TO THE NatioNal ElECtriCal …
www.mikeholt.com4 Mike Holt’s illustrated Guide to Understanding the 2014 National Electrical Code, Volume 1 90.2 | Introduction to the National Electrical Code. d.ted by other written agreements either designated by Are loca or recognized by public service commissions, utility commis-
690 ARTICLE Solar Photovoltaic (PV) Systems - Mike Holt
www.mikeholt.comINTRODUCTION TO ARTICLE 690—SOLAR PHOTOVOLTAIC (PV) SYSTEMS You’ve seen, or maybe own, photocell-powered devices such as night lights, car coolers, and toys. These generally consist of a small solar panel and a small light or motor. Typically, these run on less than 10V dc and draw only a fraction of an ampere. These kinds of devices are
1 Basic Principles of - Mike Holt
www.mikeholt.comA magnetic starter or other motor controllers may include overload devices, or they may be an integral part of the motor, particularly with small motors. ... IEC motor starters are often less expensive, smaller in size, are tai-lored for specific motor performance requirements, and
ARTICLE 250 Grounding and Bonding - Mike Holt
www.mikeholt.comMetal parts of electrical raceways, cables, enclosures, and equipment must be connected to the supply source via the effective ground-fault current path. Figures 250–12 and 250–13 (2) Equipment Grounding. Metal parts of electrical equipment
AC 800 Communications Circuits - Mike Holt
www.mikeholt.comductor or grounding electrode conductor [800.100(A)(4)] helps reduce differences in potential between communications circuits and other metallic systems during lightning events. 800.93 Grounding or Interruption of Metallic Sheath Members of Communications Cables. (A) Entering Buildings. In installations where the communications
ARTICLE 250 GROUNDING AND BONDING - Mike Holt
www.mikeholt.comation of overcurrent protection devices in the event of a ground fault. Over the past several Code cycles, this article was extensively revised to organize it better and make it easier to understand and implement. It’s arranged in a logical manner, so it’s a good idea to just read through Article 250 to get a big picture view—after
ARTICLE 250 Grounding and Bonding - Mike Holt
www.mikeholt.comArticle 250 covers the grounding requirements for providing a path to the earth to reduce overvoltage from lightning, and the bonding requirements for a low-impedance fault current path back to the source of the electrical supply to facilitate the opera-
CHAPTER METHODS AND MATERIALS - Mike Holt
www.mikeholt.comMany electricians call this plastic cable Romex®. • Article 338. Service-Entrance Cable (Types SE and USE). Service-entrance cable can be a single-conductor or a multiconductor assembly within an overall nonmetallic covering. This cable is used primarily for services not over 600V, but is also permitted for feed-ers and branch circuits.
Similar queries
Table of Contents, Mike Holt Enterprises, Mike Holt, 1 Basic Principles of, S Illustrated Guide to Understanding, ARTICLE 90 INTRODUCTION TO THE NatioNal ElECtriCal, 2014 National Electrical Code, National Electrical Code, Solar, Magnetic, Motor, Motor starters, Grounding, Electrical, 800 Communications Circuits, Ductor, Communications circuits, ARTICLE 250 Grounding and Bonding, Overcurrent, Devices, Article 250, Cable, Entrance cable