Example: stock market

2-Colour Display High-Precision Digital Pressure Switch ...

2-Colour DisplayHigh-Precision Digital Pressure SwitchThe settings of the master sensor can be copied to the slave sensors. Reduced setting efforts Reduced chance of set-value input errorSettings can be Settings can be copiedcopied to up to to up to 1010 slave sensors at once. slave sensors at can be copied to up to 10 slave sensors at setting-step setting3-step settingPushPushPushEnd setting3 PushPushPush12 Adjust to set-value with vacuum range. Rated Pressure range: to kPa2 added outputs: NPN or PNP open collector 2 outputs NPN or PNP open collector 1 output + analogue output(1 to 5 V or 4 to 20 mA) 101 kPa0 MasterUnit 1 Slave Unit 2 Unit 10 CopyCopyCopyExpanded Pressure rangefor positive Pressure typeto the vacuum range: Rated Pressure range: to MPa1 MPa0 MPa( 100 kPa) ZSE30A(F)/ISE30A RoHS compliantWithstand pressureMinimum unit settingRated Pressure range Secret code setting functionThe key locking function keeps unauthorized users from tampering with buttons.

Withstand pressure Minimum unit setting Rated pressure range Secret code setting function The key locking function keeps unauthorized users from tampering with buttons.

Tags:

  Colour, Functions, Digital

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 2-Colour Display High-Precision Digital Pressure Switch ...

1 2-Colour DisplayHigh-Precision Digital Pressure SwitchThe settings of the master sensor can be copied to the slave sensors. Reduced setting efforts Reduced chance of set-value input errorSettings can be Settings can be copiedcopied to up to to up to 1010 slave sensors at once. slave sensors at can be copied to up to 10 slave sensors at setting-step setting3-step settingPushPushPushEnd setting3 PushPushPush12 Adjust to set-value with vacuum range. Rated Pressure range: to kPa2 added outputs: NPN or PNP open collector 2 outputs NPN or PNP open collector 1 output + analogue output(1 to 5 V or 4 to 20 mA) 101 kPa0 MasterUnit 1 Slave Unit 2 Unit 10 CopyCopyCopyExpanded Pressure rangefor positive Pressure typeto the vacuum range: Rated Pressure range: to MPa1 MPa0 MPa( 100 kPa) ZSE30A(F)/ISE30A RoHS compliantWithstand pressureMinimum unit settingRated Pressure range Secret code setting functionThe key locking function keeps unauthorized users from tampering with buttons.

2 Power-saving functionPower consumption is reduced by turning off the monitor (power consumption reduced by up to 20%.) Resolution- Switch functionIt reduces the monitor to flicker. MPa/kPa Switch functionVacuum, compound and/or positive Pressure can be displayed both in MPa or configuration allows mounting in four clip type allows easy removal of s type and size can be to MPa1 MPa0 MPa( 100 kPa)ISE30A (positive) to kPa 101 kPa0 ZSE30A (vacuum) to kPa 100 kPa100 kPa0 ZSE30AF (compound) kPa500 kPa500 kPaNPN or PNP open collector 1 outputNPN or PNP open collector 2 outputsNPN or PNP open collector 1 output + Analogue output (voltage or current)OutputR1/8, NPT1/8 (M5 female threaded) 4, 6, 5/32, 1/4 one-touch fittingsPipingSet Pressure range to MPa to to kPaReplaceable one-touch fittingsConnector cover Display allows easy reading of displayed.

3 MPaLead wire4-digit displayAdditional functionsOne-touch fittingClipLead wire with connector(2 m)Connector MPaPossible to check set-value during key lockingSeries 30A(New)(Accuracy does not changed, only displayed values.)1/10001/100 Series 30(Conventional)Bracket ABracket B/CMountingexampleBracket BMountingexampleBracket CMountingexamplePanel mountMountable side by side without clearanceOne opening! Reduction of panel-cut job Space-savingFeatures 1 How to OrderFor vacuum/compound pressureISE30 AFor positivepressure01 NMZSE30A01 NMRated Pressure rangeISE30A to 1 MPaOutputNPN open collector 1 outputPNP open collector 1 outputNPN open collector 2 outputsPNP open collector 2 outputsNPN open collector 1 output + Analogue voltage outputNPN open collector 1 output + Analogue current outputPNP open collector 1 output + Analogue voltage outputPNP open collector 1 output + Analogue current outputNPABC Note)D Note)E Note)F Note)Rated Pressure rangeZSE30 AZSE30AF0 to 101 kPa 100 to 100 kPaOption 1 Without lead wireLead wire with connector(Lead wire length 2 m) Note)LLead wire with connector(lead wire length 2 m) Note)and with connector coverG Note) For output types N and P, the number of core of lead wires will be 3, and for other types, it will be unit Display Note 2)

4 Switching functionFixed SI unit Note 3)With unit Display Note 2) switching function(Initial value PSI) PMDisplay unitNote 2) Under the New Measure-ment Law, sales of switches with the unit switching function have not been allowed for use in 3) Fixed unit kPa, MPaPipingR1/8 (M5 female threaded)NPT1/8 (M5 female threaded)One-touch fitting 4 mm, 5/32 inchOne-touch fitting 6 mmOne-touch fitting 1/4 inchOne-touch fitting 4 mm, 5/32 inchOne-touch fitting 6 mmOne-touch fitting 1/4 inch01N01C4HC6HN7HC4LC6LN7 LStraight typeElbow typeNote) Made to OrderNote) Made to OrderNote 1) Made to OrderNote)Note 1)Option 3 SymbolCalibrationcertificate YKTO perating manualBookletMade to Order ( )X510 For M12 4-pinpre-wired connectorAvailable only for output A or B .2-Color Display High-Precision Digital Pressure SwitchSeries ZSE30A(F)/ISE30A RoHSConnector coverOption 2 NoneBracket AA1 Bracket BA2 Bracket CA3 Panel mount adapterBPanel mount adapter + Front protection coverD 1 SpecificationsPiping SpecificationsModel01N01C4HC6 HSensor Pressure receiving area: SiliconC3602 (electroless nickel plated)O-ring: HNBRN7HC4LC6LN7L 1/4 inch 6 mm 4 mm 5/32 inch 1/4 inch 6 mm 4 mm 5/32 inch NPT1/8M5 x R1/8M5 x One-touch fitting, Straight typeOne-touch fitting, Elbow typeSensor Pressure receiving areaPiping portIncluding lead wire with connector (3 cores, 2 m)Including lead wire with connector (4 cores, 2 m)Excluding lead wire with connectorPBT, POM, Stainless steel 304, C3604 (electroless nickel plated)O-ring.

5 NBR81 g85 g43 g70 g74 g32 gPort sizeWettedpartsmaterialWeight71 g75 g33 g73 g77 g35 g75 g79 g37 g73 g77 g35 g75 g79 g37 gOptional Part optional parts are required separately, use the following part numbers to place an ABracket BBracket CPanel mount adapterPanel mount adapter + front protection coverFront protection coverLead wire with connectorLead wire with connectorLead wire with connector (with connector cover)Mounting screw (with 2 pcs. of M3 x 5L)Mounting screw (with 2 pcs. of M3 x 5L)Mounting screw (with 2 pcs. of M3 x 5L)Mounting screw (with 2 pcs. of M3 x 8L)Mounting screw (with 2 pcs. of M3 x 8L)3 cores, for 1 output, 2 m4 cores, for 2 outputs, 2 m3 cores, for 1 output, 2 mPart wire with connector (with connector cover)Lead wire with a connector for copyingLead wire unit with a connector for copyingOne-touch fittings 4 mm straightOne-touch fittings 6 mm straightOne-touch fittings 1/4 inch straightOne-touch fittings 4 mm elbowOne-touch fittings 6 mm elbowOne-touch fittings 1/4 inch elbow4 cores, for 2 outputs, 2 m3 cores, copy function, 1 mCopy function (up to 10 slaves)O-ring, one-touch clip includedO-ring, one-touch clip includedO-ring, one-touch clip includedO-ring, one-touch clip includedO-ring, one-touch clip includedO-ring, one-touch clip includedPart 1) If applied Pressure fluctuates near the set value, set the hysteresis above the fluctuation range to prevent 2)

6 When analogue the voltage output is selected, a simultaneous selection of Switch output and current output is not 3) When analogue the current output is selected, a simultaneous selection of Switch output and voltage output is not (Vacuum Pressure )Rated Pressure rangeRegulating Pressure rangeProof pressureSetting/ Display resolutionApplicable fluidPower supply voltageCurrent consumptionSwitch outputRepeatabilityAnalogue outputHystere-sisDisplayDisplay accuracyIndicator lightEnviron-ment resistanceTemperature characteristicsLead to to kPa500 to 5 V (Compound Pressure ) to kPa to kPa500 kPaAir, non-corrosive gas, non-flammable gas12 to 24 VDC 10%, Ripple (p-p) 10% or less (with power supply polarity protection)40 mA or lessNPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)80 mA28 V (with NPN output)1 V or less (with load current of 80 mA) ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes 1 digit 1% or lessApprox.

7 1 k 1% or less4-digit, 7-segment, 2-Colour LCD (Red and Green) 2% 1 digit (ambient temperature of 25 30 C)Lights up when Switch output is ON. OUT1: Green, OUT2: RedIP40 Operating: 0 to 50 C, Stored: 10 to 60 C (no freezing or condensation)Operating/Stored: 35 to 85% RH (no condensation)1000 VAC for 1 minute between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Megohmmeter)10 to 150 Hz, mm amplitude (or 20 m/s2 acceleration), in X, Y, Z directions, for 2 hours each (Non-energised)100 m/s2 in X, Y, Z directions, 3 times each (non-energised) 2% (based on 25 C)CE Marking, UL/CSA, RoHS complianceVariable (0 or above) Note 1)ISE30A (Positive Pressure ) to MPa to MPaMaximum load currentMaximum applied voltageResidual voltageResponse timeShort circuit protectionVoltageoutputHysteresis mode Window comparator modeEnclosureOperating temperature rangeOperating humidity rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistance1 to 5V to 20 mA to 20 mA voltage LinearityOutput impedanceCurrentoutputOutput current LinearityLoad impedanceMaximum load impedance.

8 300 with power supply voltage of 12 V; 600 with power supply voltage of 24 V Minimum load impedance: 50 Oilproof heavy-duty vinyl cable, 3 cores , 2 m 4 cores Conductor area: mm2 (AWG26), Insulator : mmNote 2)Note 3)Series ZSE30A(F)/ISE30A2 DescriptionsAnalogue OutputOutput voltage Output output [V] output [mA] functions (Refer to pages 10 and 11 for details.)Copy functionAuto-preset functionPrecision indicator setting functionPeak Display functionBottom Display functionKey lock function (Security code input can be selected)Zero-out functionAnti-chattering functionUnit Display switching functionPower-saving modekPa MPa Switch functionDisplay resolution- Switch functionCopies the settings of the master sensor to the slave and enters rough set values automatically from the actual operating out deviations in the displayed retain the maximum Pressure value displayed during retain the minimum Pressure value displayed during key board can be locked to prevent any incorrect function of the Pressure Display can be set at zero when the Pressure is open to the possible malfunction due to sudden fluctuations in the primary Pressure by adjusting the response convert the Display value.

9 Reduces power Display resolution from the normal value of 1/1000 to 1 reduces the monitor to the unit between kPa and unit being used (only kPa and MPa).Unit displayLights up when Switch output (OUT1) is turned Output Display (Green)Use this button to select the mode or increase the ON/OFF set is also used for switching to the peak Display mode. UP buttonUse this button to Switch the mode and set the set SET buttonUse this button to select the mode or decrease the ON/OFF set is also used for switching to the bottom value Display mode. DOWN buttonLights up when Switch output (OUT2) is turned Output Display (Red)Displays the current Pressure condition, setting mode, and error codes. A Display colour type can be selected from either a single colour Display with red or green, or 2-Colour Display in which green and red are switched accordeing to the output.

10 Four different Display settings are displayRangeFor vacuumpressureFor compound pressureFor positivepressureRated Pressure to kPaA B0C 101 kPa to kPa 100 kPa 100 kPa to MPa MPa01 MPaSeries ZSE30A(F)/ISE30A2- colour DisplayHigh-Precision Digital Pressure Switch3+ Brown DC (+)Black OUTBlue DC ( )FUNCLoad+ LoadBrown DC (+)Black OUTBlue DC ( )FUNC12 to24 VDCB rown DC (+)Black OUT1 White OUT2 FUNCBlue DC ( )LoadLoad+ 12 to24 VDCB rown DC (+)Black OUT1 White OUT2 FUNCBlue DC ( )LoadLoad+ 12 to24 VDC12 to24 VDCMain circuitMain circuitMain circuitMain circuitInternal Circuits and Wiring ExamplesMax. 80 mAResidual voltage 1 V or lessMax. 28 V, 80 mAResidual voltage 1 V or lessMax. 80 mAResidual voltage 1 V or lessMax. 28 V, 80 mAResidual voltage 1 V or lessZ/ISE30A(F)OutputNPN (1 output)NNPN (2 outputs)APNP (2 outputs)BPNP (1 output)PNote) The FUNC terminal is connected using a dedicated lead wire (ZS-38-5L or ZS-38-U) when the copy function is used.


Related search queries