Example: confidence

2013 EdITIoN - US Pipe

For FIrE ProTECTIoN, WaTEr & WasTEWaTEr2013 EdITIoNPrEssUrE CLass/THICKNEss CLass3" 36"PRESSURE CLASS/THICKNESS CLASSNSF Certified toANSI/NSF 61P 2866 . DIP . PIPE pipe and foundry company / / REVISED pipe and foundry co. usp 0550 pressure cLass/THicKness cLass Each of the following is a nationally recognized standards organization: American National Standards Institute (ANSI) American Water Works Association (AWWA) American Society for Testing and Materials (ASTM) Underwriters Laboratories (UL) National Fire Protection Association (NFPA) National Sanitation Foundation (NSF) Factory Mutual (FM)TYTON JOINT , FIELD LOK 350 and FLANGE TYTE Gaskets meet the specifications, performance requirements and pressure ratings in accordance with standard: ANSI/AWWA C111 Joints for Ductile-Iron Pressure Pipe and Fittings. These gaskets are manufactured in the following elastomer compounds: Styrene Butadiene-(SBR), Acrylonitrile Butadiene-(NBR) and Ethylene Propylene Diene Monomer-(EPDM), Polychloroprene-Neoprene (CR) and Fluorocarbon (FKM) PROTECTO 401 CERAMIC EPOXY linings furnished with our products conform to Pipe s submittal BRO-068 (PROTECTO 401 Ceramic Epoxy Lined Ductile Iron Pipe & Fittings for Force Mains and Gravity Sewer Lines).

For FIrE ProTECTIoN, WaTEr & WasTEWaTEr 2013 EdITIoN PrEssUrE CLass/THICKNEss CLass 3"–36"

Tags:

  Edition, 2013, Edition 2013

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 2013 EdITIoN - US Pipe

1 For FIrE ProTECTIoN, WaTEr & WasTEWaTEr2013 EdITIoNPrEssUrE CLass/THICKNEss CLass3" 36"PRESSURE CLASS/THICKNESS CLASSNSF Certified toANSI/NSF 61P 2866 . DIP . PIPE pipe and foundry company / / REVISED pipe and foundry co. usp 0550 pressure cLass/THicKness cLass Each of the following is a nationally recognized standards organization: American National Standards Institute (ANSI) American Water Works Association (AWWA) American Society for Testing and Materials (ASTM) Underwriters Laboratories (UL) National Fire Protection Association (NFPA) National Sanitation Foundation (NSF) Factory Mutual (FM)TYTON JOINT , FIELD LOK 350 and FLANGE TYTE Gaskets meet the specifications, performance requirements and pressure ratings in accordance with standard: ANSI/AWWA C111 Joints for Ductile-Iron Pressure Pipe and Fittings. These gaskets are manufactured in the following elastomer compounds: Styrene Butadiene-(SBR), Acrylonitrile Butadiene-(NBR) and Ethylene Propylene Diene Monomer-(EPDM), Polychloroprene-Neoprene (CR) and Fluorocarbon (FKM) PROTECTO 401 CERAMIC EPOXY linings furnished with our products conform to Pipe s submittal BRO-068 (PROTECTO 401 Ceramic Epoxy Lined Ductile Iron Pipe & Fittings for Force Mains and Gravity Sewer Lines).

2 Pipe certifies that our applicator met the requirements of States Pipe and Foundry Company s ductile iron pipe meets or exceeds the requirements of the national standards listed above that relate to pipe manufacture and component hereby certify material furnished by Pipe & Foundry Company, LLC, either for your stock or for direct shipment to your customer, are manufactured and tested in accordance with the above standards, and meet or exceed the requirements and recommendation : Check with your Pipe Sales Representative for ready reference, standard for ductile iron pipe are listed below:Standard DesignationSubject CoveredANSI/AWWA C150 C151 PipeANSI/AWWA C110 Cast IronANSI/AWWA C153 Ductile IronANSI/AWWA C111 Gasket JointsANSI/AWWA C115 PipeANSI/AWWA C104 Mortar LiningsANSI/AWWA C116 Bonded Epoxy CoatingANSI/AWWA C105 & ASTM A674 Polyethylene Encasement for Ductile Iron PipeANSI/AWWA C600 InstallationASTM A746 Gravity SewersASTM A716 Ductile Iron Culvert PipeNFPA Outside Protection 24 Fire Protection PipingAny materials included but not covered by the above specifications will be per manufacturer s , FIELD LOK 350 and FLANGE-TYTE are Registered Trademarks of Pipe and Foundry Company, CLASS/THICKNESS CLASSSELECTIoN TAbLE foR dUCTILE IRoN PIPENSF Certified toANSI/NSF 61P 3866.

3 DIP . PIPE pipe and foundry company / / REVISED pipe and foundry co. usp 0550 pressure cLass/THicKness cLass SizeInchesPressure ClasspsiNominal ThicknessInchesOD*InchesTYTON JointTR FLEX JointHP LOK table shows pressure class of pipe necessary for the rated water working pressures. The thicknesses in this table are equal to or in excess of those required to withstand the rated working pressures plus a surge allowance of 100 psi. Ductile Iron pipe for working pressures higher than 350 psi FORM SPECIFICATION;1. This specification covers the general requirements for Pipe Ductile Iron Pressure Pipe for conveying water and other Pipe Ductile Iron Pipe, 3 through 64 , shall meet the requirements of ANSI/AWWA C151 and ANSI/AWWA C150 Joints Rubber-gasket joints shall be TYTON Joint 3 64 and meet the requirements of ANSI/AWWA C111 Coating and Lining Outside coating shall be an asphaltic coating approximately one mil thick.

4 Pipe shall be cement-mortar lined per ANSI/AWWA C104 Including bell; average weight per foot, based on calculated weight of pipe before rounding.*Tolerances of OD of spigot end; 4 12 in. in., 14-24 in + in., in., 30-48in. + in., , 54-64in. +.04, Wt. Per Ft. Pounds3 350 Thickness, dimensions and Weights of TYToN , Tr FLEX and HP LoK Joint ductile Iron PipePRESSURE CLASS/THICKNESS CLASSSELECTIoN TAbLE foR dUCTILE IRoN PIPENSF Certified toANSI/NSF 61P 4866 . DIP . PIPE pipe and foundry company / / REVISED pipe and foundry co. usp 0550 pressure cLass/THicKness cLass Certified toANSI/NSF 61 This table shows thickness class of pipe necessary for the rated water working pressures. The thicknesses in this table are equal to or in excess of those required to withstand the rated working pressures plus a surge allowance of 100 psi. Ductile Iron pipe for working pressures higher than 350 psi FORM SPECIFICATION;1.

5 This specification covers the general requirements for Pipe Ductile Iron Pressure Pipe for conveying water and other Pipe Ductile Iron Pipe, 3 through 64 , shall meet the requirements of ANSI/AWWA C151 and ANSI/AWWA C150 Joints Rubber-gasket joints shall be TYTON Joint 3 64 and meet the requirements of ANSI/AWWA C111 Coating and Lining Outside coating shall be an asphaltic coating approximately one mil thick. Pipe shall be cement-mortar lined per ANSI/AWWA C104 NOTE: Thicknesses and dimensions of 4" through 64" Ductile Iron pipe conform to ANSI/AWWA C151 Weights may vary from the standard because of differ-ences in bell weights.*Tolerance of of spigot end: 4-12 in., in.; 14-24 in., + in., in.; 30-48 in., + in., in.; 54-64 in., + in., in. Including bell; calculated weight of pipe rounded off to nearest 5 Class AVG. WEIGHT LENGTH Pounds OuTSIDE TYTON TR FLEX HP LOK SIzE THICKNESS THICKNESS DIAMETER* JOINT JOINT JOINT Inches CLASS Inches Inches 3 51 170 3 52 185 3 53 205 3 54 220 3 55 240 3 56 255 4 51 215 220 4 52 235 240 4 53 260 265 4 54 280 285 4 55

6 300 305 4 56 320 325 6 50 305 310 6 51 335 345 6 52 370 380 6 53 400 410 6 54 435 440 6 55 465 475 6 56 495 505 8 50 430 445 8 51 475 490 8 52 520 530 8 53 560 575 8 54 605 620 8 55 650 660 8 56 690 705 10 50 570 590 10 51 625 645 10 52 680 700 10 53 730 755 10 54 785 810 10 55 840 860 10 56 890 915 12 50 725 760 12 51 790 825 12 52 855 890 12 53 920 955 12 54 985 1020 12 55 1045 1080 12 56 1110 1145 PRESSURE CLASS/THICKNESS CLASSSELECTIoN TAbLE foR dUCTILE IRoN PIPENSF Certified toANSI/NSF 61P 5866.

7 DIP . PIPE pipe and foundry company / / REVISED pipe and foundry co. usp 0550 pressure cLass/THicKness cLass AVG. WEIGHT LENGTH Pounds OuTSIDE TYTON TR FLEX HP LOK SIzE THICKNESS THICKNESS DIAMETER* JOINT JOINT JOINT Inches CLASS Inches Inches 14 50 910 960 14 51 985 1035 14 52 1060 1110 14 53 1135

8 1185 14 54 1210 1260 14 55 1285 1335 14 56 1360 1410 16 50 1065 1135 16 51 1150 1220 16 52 1240 1305 16 53 1325 1390 16 54 1410 1475 16 55 1495 1565 16 56 1580 1650 18 50 1225 1315 18 51 1325

9 1410 18 52 1420 1505 18 53 1520 1605 18 54 1615 1700 18 55 1710 1795 18 56 1805 1895 20 50 1395 1510 20 51 1505 1615 20 52 1610 1725 20 53 1720 1830 20 54 1825 1940 20 55 1935 2045 20 56 2040 2155 Thickness Class (cont.)

10 NOTE: Thicknesses and dimensions of 4" through 64" Ductile Iron pipe conform to ANSI/AWWA C151 Weights may vary from the standard because of differences in bell weights.*Tolerance of of spigot end: 4-12 in., in.; 14-24 in., + in., in.; 30-48 in., + in., in.; 54-64 in., + in., in. Including bell; calculated weight of pipe rounded off to nearest 5 continued on next CLASS/THICKNESS CLASSSELECTIoN TAbLE foR dUCTILE IRoN PIPENSF Certified toANSI/NSF 61P 6866 . DIP . PIPE pipe and foundry company / / REVISED pipe and foundry co. usp 0550 pressure cLass/THicKness cLass Thickness Class (cont.)NOTE: Thicknesses and dimensions of 4" through 64" Ductile Iron pipe conform to ANSI/AWWA C151 Weights may vary from the standard because of differences in bell weights.*Tolerance of of spigot end: 4-12 in., in.; 14-24 in., + in., in.; 30-48 in., + in., in.; 54-64 in., + in., in. Including bell; calculated weight of pipe rounded off to nearest 5 continued on next page.