- fx3uc (D,DS,DSS) SERIES PROGRAMMABLE CONTROLLERS hardware MANUALThis manual describes the part names, dimensions, mounting,cabling and specifications for the product. This manual is extractedfrom fx3uc (D,DS,DSS) Series User's Manual - hardware to fx3uc Series User's Manual - hardware Edition use, read this manual and manuals of relevant products fullyto acquire proficiency in the handling and operating the sure to learn all the product information, safety information,and , store this manual in a safe place so that it can be taken out andread whenever necessary. Always forward it to the end company name and the product name to be described in thismanual are the registered trademarks or trademarks of May 2011 Specifications are subject to change without notice. 2007 Mitsubishi Electric CorporationSafety Precaution (Read these precautions before use.)

FX3UC (D,DS,DSS) SERIES PROGRAMMABLE CONTROLLERS HARDWARE MANUAL This manual describes the part names, dimensions, mounting, cabling and …

Tags:

  Hardware, Fx3uc, 286e fx3uc, 286e, D dss

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 286E FX3UC(D DSS)Hardware A4編集用 - …

1 - fx3uc (D,DS,DSS) SERIES PROGRAMMABLE CONTROLLERS hardware MANUALThis manual describes the part names, dimensions, mounting,cabling and specifications for the product. This manual is extractedfrom fx3uc (D,DS,DSS) Series User's Manual - hardware to fx3uc Series User's Manual - hardware Edition use, read this manual and manuals of relevant products fullyto acquire proficiency in the handling and operating the sure to learn all the product information, safety information,and , store this manual in a safe place so that it can be taken out andread whenever necessary. Always forward it to the end company name and the product name to be described in thismanual are the registered trademarks or trademarks of May 2011 Specifications are subject to change without notice. 2007 Mitsubishi Electric CorporationSafety Precaution (Read these precautions before use.)

2 This manual classifies the safety precautions into two categories: and .Depending on the circumstances, procedures indicated by may also cause severe is important to follow all precautions for personal safety. Manual NumberJY997D28601 RevisionEDateMay 2011 Indicates that incorrect handling may causehazardous conditions, resulting in death orsevere that incorrect handling may causehazardous conditions, resulting in medium orslight personal injury or physical AND MAINTENANCE PRECAUTIONS Do not touch any terminal while the PLC's power is so may cause electric shock or malfunctions. Before cleaning or retightening terminals, cut off all phases ofthe power supply to do so may cause electric AND MAINTENANCE PRECAUTIONS Use the battery for memory backup correctly in fx3uc SeriesUser's Manual - hardware Use the battery only for the specified Connect the battery Do not charge, disassemble, heat, put in fire, short-circuit, connect reversely, weld, swallow or burn the battery, or apply excessive forces (vibration, impact, drop, etc.)

3 To the Do not store or use the battery at high temperatures or expose to direct Do not expose to water, bring near fire or touch liquid leakage or other contents Incorrect handling of the battery may cause heat excessive generation, bursting, ignition, liquid leakage or deformation, and lead to injury, fire or failures and malfunctions of facilities and other equipment. Before modifying or disrupting the program in operation orrunning the PLC, carefully read through this manual and theassociated manuals and ensure the safety of the operation error may damage the machinery or cause AND MAINTENANCE PRECAUTIONS Turn off the power to the PLC before attaching or detaching thememory cassette. If the memory cassette is attached ordetached while the PLC's power is on, the data in the memorymay be destroyed, or the memory cassette may be damaged.

4 Do not disassemble or modify the so may cause fire, equipment failures, or repair, contact your local Mitsubishi Electric distributor. Turn off the power to the PLC before connecting or disconnectingany extension to do so may cause equipment failures or malfunctions. Turn off the power to the PLC before attaching or detaching thefollowing to do so may cause equipment failures or Peripheral devices, extension blocks, connector conversion adapter, extension power supply units, special adapters, and FX Series terminal Battery and memory cassettesDISPOSAL PRECAUTIONS Please contact a certified electronic waste disposal companyfor the environmentally safe recycling and disposal of disposing of batteries, separate them from other wasteaccording to local regulations.(For details of the Battery Directive in EU countries, refer toFX3UC Series User's Manual - hardware Edition.)

5 TRANSPORTATION AND STORAGE PRECAUTIONS Before transporting the PLC, turn on the power to the PLC tocheck that the BAT LED is the PLC is transported with the BAT LED on or the batteryexhausted, the battery-backed data may be unstable duringtransportation. The PLC is a precision instrument. During transportation, avoidimpacts larger than those specified in Section Failure to doso may cause failures in the transportation, verify the operations of the PLC. When transporting lithium batteries, follow requiredtransportation regulations.(For details of the regulated products, refer to fx3uc SeriesUser's Manual - hardware Edition.)Certification of UL, cUL standardsFX3UC series main units, FX3U series special adapter, extensionpower supply unit and FX2N/FX2NC series input/output extensionblocks supporting UL, cUL standards are as follows:UL, cUL file number :E95239 Models :MELSEC FX3U(C) series manufacturedFX3UC- MT/DFX3UC- MT/DSSW here indicates:16,32,64,96FX3UC-16MR/D-TFX3UC -16MR/DS-TFX3U-232 ADP(-MB)FX3U-485 ADP(-MB)FX3U-CF-ADPFX3U-4AD-ADPFX3U-4DA- ADPFX3U-3A-ADPFX3U-4AD-PT-ADPFX3U-4AD-PT W-ADP FX3U-4AD-PNK-ADPFX3U-4AD-TC-ADPFX3UC-1PS -5 VModels :MELSEC FX2NC series manufacturedFX2NC-16EX(-DS)FX2NC-32EX(-D S)FX2NC-16 EYT(-DSS) FX2NC-32 EYT(-DSS)FX2NC-16EX-T(-DS)FX2NC-16 EYR-T(-DS)Models.

6 MELSEC FX2N series manufacturedFX2N-8ER-ES/ULFX2N-8EX-ES/UL FX2N-8 EYR-ES/ULFX2N-8 EYR-S-ES/ULFX2N-8 EYT-ESS/ULFX2N-8EX-UA1/ULFX2N-16EX-ES/UL FX2N-16 EYR-ES/ULFX2N-16 EYT-ESS/UL FX2N-16 EYSC ompliance with EC directive (CE Marking)This document does not guarantee that a mechanical systemincluding this product will comply with the following to EMC directive and LVD directive of the entiremechanical system should be checked by the user / more details please contact the local Mitsubishi Electric for Compliance with EMC directiveThe following products have shown compliance through directtesting (of the identified standards below) and design analysis(through the creation of a technical construction file) to the EuropeanDirective for Electromagnetic Compatibility (2004/108/EC) whenused as directed by the appropriate This product is designed for use in industrial Manufactured by:Mitsubishi Electric Corporation2-7-3 Marunouchi, Chiyoda-ku, Tokyo, 100-8310 Japan Manufactured at:Mitsubishi Electric Corporation Himeji Works840 Chiyoda-machi, Himeji, Hyogo, 670-8677 Japan Authorized Representative in the European Community:Mitsubishi Electric Europe Str.

7 8, 40880 Ratingen, :Programmable Controller (Open Type Equipment)Models :MELSEC FX3U(C) series and FX2NC series manufacturedfrom May 1st, 2005FX3U-FLROM-16FX3U-FLROM-64 Lfrom June 1st, 2005FX3U-232 ADPFX3U-485 ADPFX3U-4AD-ADPFX3U-4DA-ADPFX3U-4AD-PT-A DP FX3U-4AD-TC-ADPFX3U-FLROM-64from April 1st, 2007FX3U-232 ADP-MBFX3U-485 ADP-MBfrom September 1st, 2007 fx3uc - MT/DFX3UC- MT/DSSW here indicates:16,32,64,96from October 1st, 2007FX3UC-1PS-5 VFX2NC- EXFX2NC- EYTFX2NC- EX-DSFX2NC- EYT-DSSW here indicates:16,32FX2NC-16EX-TFX2NC-16EX-T- DSfrom December 1st, 2007FX3U-4AD-PTW-ADP FX3U-4AD-PNK-ADPfrom June 1st, 2009FX3U-3A-ADPFX3U-CF-ADPfrom September 1st, 2010 fx3uc -16MR/D-TFX3UC-16MR/DS-Tfrom May 1st, 2011FX3U-FLROM-1 MModels : MELSEC FX2NC series manufacturedfrom March 1st, 1999FX2NC- EX-DSFX2NC- EYT-DSSW here indicates:16,32from August 1st, 1999 FX2NC-16EX-T-DS FX2NC-16 EYR-T-DSfrom October 1st, 2007 FX2NC- EXFX2NC- EYTW here indicates:16,32FX2NC-16EX-TFX2NC-16 EYR-TModels : MELSEC FX2N series manufacturedfrom July 1st, 1997FX2N-16EX-ES/UL FX2N-16 EYR-ES/ULFX2N-16 EYT-ESS/ULfrom August 1st, 2005 FX2N-8ER-ES/ULFX2N-8EX-ES/ULFX2N-8 EYR-ES/UL FX2N-8 EYT-ESS/ULfrom September 1st, 2010FX2N-8 EYR-S-ES/ULFor the products above, PLC s manufacturedbefore March 31st, 2002 are compliant with EN50081-2 (EN61000-6-4) and EN50082-2 :2007 Programmablecontrollers-Equipment requirements and testsCompliance with all relevant aspects ofthe standard.

8 EMI Radiated Emission Conducted Emission EMS Radiated electromagnetic field Fast transient burst Electrostatic discharge High-energy surge Voltage drops and interruptions Conducted RF Power frequency magnetic fieldStandardRemarkEN61000-6-4:2007- Generic emission standard Industrial environmentEN50081-2:1993 ElectromagneticcompatibilityCompliance with all relevant aspects ofthe standard. Emission-Enclosure port Emission-Low voltage AC mains port Emission-Telecommunications/network portEN61000-6-2:2005- Generic immunity standard Industrial environmentCompliance with all relevant aspects ofthe standard. Radio-frequency electromagnetic modulated Fast transients Electrostatic discharge Surges Voltage dips Voltage interruptions Radio-frequency common mode Power-frequency magnetic fieldJY997D28601E(ENGLISH)PLC s manufactured from April 1st, 2002 to April 30th, 2006 arecompliant with EN50081-2 (EN61000-6-4) and EN61131-2:1994+A11:1996+A12:2000 PLC s manufactured after May 1st, 2006 are compliant withEN61131-2:2007 Requirement for Compliance with LVD directiveThe following products have shown compliance through directtesting (of the identified standards below) and design analysis(through the creation of a technical construction file) to the EuropeanDirective for Low Voltage (2006/95/EC) when used as directed bythe appropriate.

9 Programmable Controller (Open Type Equipment)Models : MELSEC fx3uc series manufacturedfrom September 1st, 2010FX3UC-16MR/D-T fx3uc -16MR/DS-TModels : MELSEC FX2NC series manufacturedfrom August 1st, 1999FX2NC-16 EYR-T-DSfrom October 1st, 2007FX2NC-16 EYR-T*Compliance to BSEN61010-1 is claimed through virtue of directcompliance to IEC1010-1 and Amendment :MELSEC FX2N series manufacturedfrom July 1st, 1997FX2N-16 EYR-ES/ULfrom August 1st, 2005 FX2N-8ER-ES/ULFX2N-8 EYR-ES/ULfrom September 1st, 2010FX2N-8 EYR-S-ES/ULFor the products above, PLC s manufacturedbefore March 31st, 2002 are compliant with IEC1010-1 PLC s manufactured from April 1st, 2002 to April 30th, 2006 arecompliant with EN61131-2:1994+A11:1996+A12:2000 PLC s manufactured after May 1st, 2006 are compliant withEN61131-2:2007 Caution for compliance with EC DirectiveInstallation in EnclosureProgrammable logic controllers are open-type devices that must beinstalled and used within conductive control boxes.

10 Please use theFX3UC (D,DS,DSS) Series programmable logic controllers whileinstalled in conductive shielded control boxes. Please secure thecontrol box lid to the control box (for conduction). Installation within acontrol box greatly affects the safety of the system and aids inshielding noise from the programmable logic for Analog Products in useThe analog special adapters have been found to be compliant to theEuropean standards in the aforesaid manual and directive. However,for the very best performance from what are in fact delicatemeasuring and controlled output device Mitsubishi Electric would liketo make the following points;As analog devices are sensitive by nature, their use should beconsidered carefully. For users of proprietary cables (integral withsensors or actuators), these users should follow the manufacturers installation Electric recommends that shielded cables be used.