Example: barber

3185 - PR electronics

Loop powered isolator31851 or 2 channel input loop powered isolator Signal 1:1 functional range mA Low input voltage drop and fast response time Excellent accuracy and high load stability Slimline 6 mm housing ApplicationsApplication1:1 input loop powered isolator of current signals in the range0(4)..20 mA. 3185 is an easy mounting DIN rail unit. A very competitive choice in terms of both price andtechnology for galvanic isolation of current signals. Provides surge suppression and protects control systemsfrom transients and noise. 3185 eliminates ground loops and can be used for measuringfloating signals. The device can be mounted in Safe area or in Zone 2 and Div 2. area. Technical characteristics3185 is powered by the analog input current signal loop. Low input voltage drop, typ V + Vout. Excellent conversion accuracy, better than in the mA. Functional range is mA which means that 3185 isNAMUR NE43 compliant.

Loop powered isolator 3185 –1 or 2 channel input loop powered isolator –Signal 1:1 functional range 0...23 mA –Low input voltage drop and fast response time

Tags:

  5831

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 3185 - PR electronics

1 Loop powered isolator31851 or 2 channel input loop powered isolator Signal 1:1 functional range mA Low input voltage drop and fast response time Excellent accuracy and high load stability Slimline 6 mm housing ApplicationsApplication1:1 input loop powered isolator of current signals in the range0(4)..20 mA. 3185 is an easy mounting DIN rail unit. A very competitive choice in terms of both price andtechnology for galvanic isolation of current signals. Provides surge suppression and protects control systemsfrom transients and noise. 3185 eliminates ground loops and can be used for measuringfloating signals. The device can be mounted in Safe area or in Zone 2 and Div 2. area. Technical characteristics3185 is powered by the analog input current signal loop. Low input voltage drop, typ V + Vout. Excellent conversion accuracy, better than in the mA. Functional range is mA which means that 3185 isNAMUR NE43 compliant.

2 Inputs and outputs are floating and galvanically separated. The output is voltage limited to VDC. High galvanic isolation of kVAC. Fast response time < 5 ms. Excellent signal/noise ratio > 60 dB. Mounting / installation / programmingDIN rail mounting with up to 330 channels per meter. Temperature operation range is from +70 C. This page is automatically generated on the basis of information provided on and affiliated websites. It is provided to you as a service and for informationpurpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability3185-121418 Environmental ConditionsOperating C to +70 CStorage C to +85 CCalibration CRelative < 95% RH (non-cond.)Protection degree 2 & meas. /overvoltage cat. IIMechanical specificationsDimensions (HxWxD).

3 113 x x 115 mmWeight gDIN rail EN 60715/35 mmWire x mm2 / AWG wireScrew terminal 4 gCommon specificationsSupplyPower dissipation, per mWIsolation voltageIsolation voltage, test kVAC / 300 VAC(reinforced)Zone 2 / Div. VACR esponse timeResponse time ( , )..< 5 msSignal / noise > 60 dBSignal dynamics, signal chainSignal dynamics, signal than frequency (3 dB)..100 HzEMC immunity < of spanExtended EMC immunity: NAMURNE21, A criterion, < 1% of spanInput specificationsCurrent inputMeasurement mAInput voltage (Unit voltage drop) + :1 Start-up current, uACurrent input overload, mAInput to output voltage drop, V + ( x Vout.)Output specificationsCurrent outputSignal mALoad (@ current output).. 600 Load < of span / 100 Voltage Vof / Ex 3 G Ex nA IIC T4 nA IIC T4 GcFM, I, Div. 2, Gp. A, B, C, D T4or Cl.

4 I, Zone 2, AEx nA IIC T4FM, I, Div. 2, Gp. A, B, C, D T4or Cl. I, Zone 2, Ex nA IIC T4 Observed authority 020/2011 ApprovalsATEX 2014/34 10 ATEX0147 /FM17CA0003 XDNV-GL f. Certific. No. Ex TR-CU 012