Example: tourism industry

334f FX3GHardware A4編集用 - Mitsubishi Electric

fx3g SERIES PROGRAMMABLE CONTROLLERS HARDWARE MANUALThis manual describes the part names, dimensions, mounting,cabling and specifications for the product. This manual is extractedfrom fx3g Series User's Manual - Hardware Edition. Refer to FX3 GSeries User's Manual - Hardware Edition for more details. Beforeuse, read this manual and manuals of relevant products fully toacquire proficiency in the handling and operating the product. Makesure to learn all the product information, safety information, , store this manual in a safe place so that you can take it out andread it whenever necessary. Always forward it to the end company name and the product name to be described in thismanual are the registered trademarks or trademarks of December 2009 Specifications are subject to change without notice. 2008 Mitsubishi Electric CorporationSafety Precaution (Read these precautions before use.)This manual classifies the safety precautions into two categories: and.

FX3G SERIES PROGRAMMABLE CONTROLLERS HARDWARE MANUAL This manual describes the part names, dimensions, mounting, cabling and specifications for the product. This manual is extracted

Tags:

  Electric, Mitsubishi, Mitsubishi electric, Fx3g

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 334f FX3GHardware A4編集用 - Mitsubishi Electric

1 fx3g SERIES PROGRAMMABLE CONTROLLERS HARDWARE MANUALThis manual describes the part names, dimensions, mounting,cabling and specifications for the product. This manual is extractedfrom fx3g Series User's Manual - Hardware Edition. Refer to FX3 GSeries User's Manual - Hardware Edition for more details. Beforeuse, read this manual and manuals of relevant products fully toacquire proficiency in the handling and operating the product. Makesure to learn all the product information, safety information, , store this manual in a safe place so that you can take it out andread it whenever necessary. Always forward it to the end company name and the product name to be described in thismanual are the registered trademarks or trademarks of December 2009 Specifications are subject to change without notice. 2008 Mitsubishi Electric CorporationSafety Precaution (Read these precautions before use.)This manual classifies the safety precautions into two categories: and.

2 Depending on the circumstances, procedures indicated by may also cause severe is important to follow all precautions for personal NumberJY997D33401 RevisionFDateDecember 2009 Indicates that incorrect handling may causehazardous conditions, resulting in death orsevere that incorrect handling may causehazardous conditions, resulting in medium orslight personal injury or physical AND MAINTENANCE PRECAUTIONS Do not touch any terminal while the PLC's power is so may cause Electric shock or malfunctions. Before cleaning or retightening terminals externally cut off allphases of the power to do so may cause Electric AND MAINTENANCE PRECAUTIONS Use the battery for memory backup correctly in fx3g SeriesUser's Manual - Hardware Use the battery only for the specified Connect the battery Do not charge, disassemble, heat, put in fire, short-circuit, connect reversely, weld, swallow or burn the battery, or apply excessive forces (vibration, impact, drop, etc.)

3 To the Do not store or use the battery at high temperatures or expose to direct Do not expose to water, bring near fire or touch liquid leakage or other contents Incorrect handling of the battery may cause heat excessive generation, bursting, ignition, liquid leakage or deformation, and lead to injury, fire or failures and malfunctions of facilities and other equipment. Before modifying or disrupting the program in operation orrunning the PLC, carefully read through this manual and theassociated manuals and ensure the safety of the operation error may damage the machinery or cause AND MAINTENANCE PRECAUTIONS Turn off the power to the PLC before attaching or detaching thememory cassette. If the memory cassette is attached ordetached while the PLC's power is on, the data in the memorymay be destroyed, or the memory cassette may be damaged. Do not disassemble or modify the so may cause fire, equipment failures, or repair, contact your local Mitsubishi Electric distributor.

4 Turn off the power to the PLC before connecting or disconnectingany extension to do so may cause equipment failures or malfunctions. Turn off the power to the PLC before attaching or detaching thefollowing to do so may cause equipment failures or Peripheral devices, Display module, expansion boards, and special adapters- Connector conversion adapter, extension blocks, and FX Series terminal blocks- Battery and memory cassetteDISPOSAL PRECAUTIONS Please contact a certified electronic waste disposal companyfor the environmentally safe recycling and disposal of disposing of batteries, separate them from other wasteaccording to local regulations.(For details of the Battery Directive in EU countries, refer toFX3G Series User's Manual - Hardware Edition.)Compliance with EC directive(CE Marking )This document does not guarantee that a mechanical systemincluding this product will comply with the following to EMC directive and LVD directive of the entiremechanical system should be checked by the user / more details please contact the local Mitsubishi Electric for Compliance with EMC directiveThe following products have shown compliance through directtesting (of the identified standards below) and design analysis(through the creation of a technical construction file) to the EuropeanDirective for Electromagnetic Compatibility (2004/108/EC) whenused as directed by the appropriate This product is designed for use in industrial applications.

5 Manufactured by: Mitsubishi Electric Corporation2-7-3 Marunouchi, Chiyoda-ku, Tokyo, 100-8310 Japan Manufactured at: Mitsubishi Electric Corporation Himeji Works840 Chiyoda-machi, Himeji, Hyogo, 670-8677 Japan Authorized Representative in the European Community: Mitsubishi Electric Europe Str. 8, 40880 Ratingen, :Programmable Controller (Open Type Equipment)Models :MELSEC fx3g series manufacturedfrom June 1st, 2005FX3U-232 ADPFX3U-485 ADPFX3U-4AD-ADPFX3U-4DA-ADPFX3U-4AD-PT-A DP FX3U-4AD-TC-ADPfrom April 1st, 2007FX3U-232 ADP-MBFX3U-485 ADP-MBfrom December 1st, 2007 FX3U-4AD-PTW-ADPFX3U-4AD-PNK-ADPfrom November 1st, 2008 fx3g - MT/ES(-A)Where indicates:14,24,40,60FX3G-232-BDFX3G-422 -BDFX3G-485-BDFX3G-EEPROM-32 LFX3G-CNV-ADPFX3G-2AD-BDFX3G-1DA-BDFX3G- 8AV-BDFX3G-5 DMfrom December 1st, 2008 fx3g - MR/ES(-A)Where indicates:14,24,40,60from March 1st, 2009FX3G- MT/ESSW here indicates:14,24,40,60from June 1st, 2009FX3U-3A-ADPfrom December 1st, 2009 fx3g - MR/DSFX3G- MT/DSFX3G- MT/DSSW here indicates.

6 14,24,40,60 TRANSPORT AND STORAGE PRECAUTIONS When transporting the fx3g Series PLC incorporating theoptional battery, turn on the PLC before shipment, confirm thatthe battery mode is set using a parameter and the ALM LED isOFF, and check the battery the PLC is transported with the ALM LED on or the batteryexhausted, the battery-backed data may be unstable duringtransportation. The PLC is a precision instrument. During transportation, avoidimpacts larger than those specified in Section Failure to doso may cause failures in the transportation, verify the operations of the PLC. When transporting lithium batteries, follow requiredtransportation regulations.(For details of the regulated products, refer to fx3g SeriesUser's Manual - Hardware Edition.)StandardRemarkEN61131-2:2003 Programmable controllers-Equipment requirements and testsCompliance with all relevant aspectsof the standard.

7 EMI Radiated Emissions Conducted Emissions EMS Radiated electromagnetic field Fast transient burst Electrostatic discharge High-energy surge Voltage drops and interruptions Conducted RF Power frequency magnetic fieldJY997D33401F(ENGLISH)Models :MELSEC FX2N series manufacturedfrom July 1st, 1997FX2N- ER-ES/UL FX2N- ET-ESS/ULWhere indicates:32,48FX2N-16EX-ES/UL FX2N-16 EYR-ES/ULFX2N-16 EYT-ESS/ULfrom April 1st, 1998FX2N-48ER-DSFX2N-48ET-DSSfrom August 1st, 1998 FX2N-48ER-UA1/ULfrom August 1st, 2005 FX2N-8ER-ES/ULFX2N-8EX-ES/ULFX2N-8 EYR-ES/UL FX2N-8 EYT-ESS/ULFor the products above, PLCs manufacturedbefore March 31st, 2002 are compliant with EN50081-2 (EN61000-6-4) and EN50082-2from April 1st, 2002 to April 30th, 2006 are compliant with EN50081-2 (EN61000-6-4) and EN61131-2:1994+A11:1996+A12:2000after May 1st, 2006 are compliant with EN61131-2:2003 Requirement for Compliance with LVD directiveThe following products have shown compliance through directtesting (of the identified standards below) and design analysis(through the creation of a technical construction file) to the EuropeanDirective for Low Voltage (2006/95/EC) when used as directed bythe appropriate :Programmable Controller (Open Type Equipment)Models :MELSEC fx3g series manufacturedfrom November 1st, 2008 fx3g - MT/ES(-A)Where indicates:14,24,40,60from December 1st, 2008 fx3g - MR/ES(-A)Where indicates:14,24,40,60from March 1st, 2009FX3G- MT/ESSW here indicates:14,24,40,60from December 1st, 2009 fx3g - MR/DSWhere indicates:14,24,40,60 Models :MELSEC FX2N series manufacturedfrom July 1st, 1997FX2N- ER-ES/UL FX2N- ET-ESS/ULWhere indicates.

8 32,48FX2N-16 EYR-ES/ULfrom April 1st, 1998FX2N-48ER-DSfrom August 1st, 1998 FX2N-48ER-UA1/ULfrom August 1st, 2005 FX2N-8ER-ES/ULFX2N-8 EYR-ES/ULFor the products above, PLCs manufacturedbefore March 31st, 2002 are compliant with IEC1010-1from April 1st, 2002 to April 30th, 2006 are compliant with EN61131-2:1994+A11:1996+A12:2000after May 1st, 2006 are compliant with EN61131-2:2003 StandardRemarkEN61000-6-4:2007- Generic emission standardIndustrial environmentEN50081-2:1993 ElectromagneticcompatibilityCompliance with all relevant aspectsof the standard. Radiated Emissions Mains Terminal Voltage EmissionsEN50082-2:1995 Electromagneticcompatibility- Generic immunity standardIndustrial environmentCompliance with all relevant aspectsof the standard. RF immunity Fast Transients ESD Conducted Power magnetic fieldsEN61131-2:1994 /A11:1996 /A12:2000 Programmable controllers-Equipment requirements and testsCompliance with all relevant aspectsof the standard.

9 RF Immunity Fast Transients ESD Damped oscillatory waveEN61131-2:2003 Programmable controllers-Equipment requirements and testsCompliance with all relevant aspectsof the standard. EMI Radiated Emissions Conducted Emissions EMS Radiated electromagnetic field Fast transient burst Electrostatic discharge High-energy surge Voltage drops and interruptions Conducted RF Power frequency magnetic fieldStandardRemarkEN61131-2:2003 Programmable controllers- Equipment requirements and testsThe equipment has been assessedas a component for fitting in asuitable enclosure which meets therequirements of EN61131-2:2003 StandardRemarkIEC1010-1:1990 /A1:1992 Safety requirements for electrical equipment for measurement, control, and laboratory use- General requirementsThe equipment has been assessedas a component for fitting in asuitable enclosure which meets therequirements of IEC 1010-1:1990+A1:1992EN61131-2:1994 /A11:1996 /A12.

10 2000 Programmable controllers- Equipment requirements and testsThe equipment has been assessedas a component for fitting in asuitable enclosure which meets therequirements of EN61131-2:1994+A11:1996+A12:2000EN61131- 2:2003 Programmable controllers- Equipment requirements and testsThe equipment has been assessedas a component for fitting in asuitable enclosure which meets therequirements of EN61131-2:2003 Caution for compliance with EC DirectiveInstallation in EnclosureProgrammable logic controllers are open-type devices that must beinstalled and used within conductive control boxes. Please use theFX3G Series programmable logic controllers while installed inconductive shielded control boxes. Please secure the control box lidto the control box (for conduction). Installation within a control boxgreatly affects the safety of the system and aids in shielding noisefrom the programmable logic manualsFX3G Series PLC (main unit) comes with this document (hardwaremanual).


Related search queries