Example: dental hygienist

624BLD RevF MULTI - FAAC

624 BLD624 BLD1 INDEX1..WARNINGS .. 32..TECHNICAL SPECIFICATIONS .. 33..LAYOUT AND COMPONENTS OF 624 BLD .. Description of components .. 34..ELECTRICAL CONNECTIONS .. J1 Terminal-board - Accessories (Fig. 2) .. Connection of relay photocells and safety devices with contact .. Connection of BUS photocells .. J2 Terminal-board - Motor, flashing lamp and fan (Fig. 2) .. J8 Connector - Motor capacitor (Fig. 2) .. J9 Terminal-board - Power supply (Fig. 2) .. J3, J5 Rapid connectors - for opening and closing limit-switches (Fig. 2) .. J6 Connector - Beam breaking sensor (Fig. 2) .. DS1 Frequency selector (Fig. 1) .. J4 Connector - for Minidec, Decoder and RP .. 65..PROGRAMMING .. 1st LEVEL PROGRAMMING .. Modification of the pre-setting.

3 1. WARNINGS Attention: Before attempting any work on the control unit (connections, maintenance), always turn off power. - Install, upstream of the system, a differential thermal breaker with adequate tripping threshold.

Tags:

  Vref, 624bld revf, 624bld

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 624BLD RevF MULTI - FAAC

1 624 BLD624 BLD1 INDEX1..WARNINGS .. 32..TECHNICAL SPECIFICATIONS .. 33..LAYOUT AND COMPONENTS OF 624 BLD .. Description of components .. 34..ELECTRICAL CONNECTIONS .. J1 Terminal-board - Accessories (Fig. 2) .. Connection of relay photocells and safety devices with contact .. Connection of BUS photocells .. J2 Terminal-board - Motor, flashing lamp and fan (Fig. 2) .. J8 Connector - Motor capacitor (Fig. 2) .. J9 Terminal-board - Power supply (Fig. 2) .. J3, J5 Rapid connectors - for opening and closing limit-switches (Fig. 2) .. J6 Connector - Beam breaking sensor (Fig. 2) .. DS1 Frequency selector (Fig. 1) .. J4 Connector - for Minidec, Decoder and RP .. 65..PROGRAMMING .. 1st LEVEL PROGRAMMING .. Modification of the pre-setting.

2 Setup and BUS system control .. 2nd LEVEL PROGRAMMING .. Setup for integrated Loop Detector .. 106..START-UP .. Board LEDS check .. Check on BUS status .. 117..AUTOMATED SYSTEM TEST .. 118..MASTER-SLAVE CONFIGURATIONS .. 129..3rd LEVEL PROGRAMMING .. Customisation of function 1510. PRE-SETTING VALUES .. 1511. NOTES .. 1612. INTERLOCK CONNECTION .. 1613. FUNCTION LOGIC TABLES .. 17 ENGLISH2CE DECLARATION OF CONFORMITYM anufacturer: FAAC : Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALYD eclares that: 624 BLD control unit conforms to the essential safety requirements of the following EEC directives 2006/95/EC Low Voltage Directive 2004/108/EC Electromagnetic Compatibility Directive Additional note: This product underwent tests in a typical uniform configuration (all products manufactured by FAAC ).

3 Bologna, 01 January 2010 The Managing Director A. Marcellan 1) ATTENTION! To ensure the safety of people, it is important that you read all the following instructions. Incorrect installation or incorrect use of the product could cause serious harm to people. 2) Carefully read the instructions before beginning to install the product. 3) Do not leave packing materials (plastic, polystyrene, etc.) within reach of children as such materials are potential sources of danger. 4) Store these instructions for future reference. 5) This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the good condition/operation of the product and/or be a source of danger.

4 6) FAAC declines all liability caused by improper use or use other than that for which the automated system was intended. 7) Do not install the equipment in an explosive atmosphere: the presence of inflammable gas or fumes is a serious danger to safety. 8) The mechanical parts must conform to the provisions of Standards EN 12604 and EN 12605. For non-EU countries, to obtain an adequate level of safety, the Stand-ards mentioned above must be observed, in addition to national legal regulations. 9) FAAC is not responsible for failure to observe Good Technique in the construction of the closing elements to be motorised, or for any defor-mation that may occur during use. 10) The installation must conform to Standards EN 12453 and EN 12445.

5 For non-EU countries, to obtain an adequate level of safety, the Stand-ards mentioned above must be observed, in addition to national legal regulations. 11) Before attempting any job on the system, cut out electrical power. 12) The mains power supply of the automated system must be fitted with an all-pole switch with contact opening distance of 3 mm or greater. Use of a 6A thermal breaker with all-pole circuit break is recommended. 13) Make sure that a differential switch with threshold of A is fitted upstream of the system. 14) Make sure that the earthing system is perfectly constructed and con-nect metal parts of the closure to it. 15) The automated system is supplied with an intrinsic anti-crushing safety device consisting of a torque control.

6 Nevertheless, its tripping thresh-old must be checked as specified in the Standards indicated at point 10. 16) The safety devices (EN 12978 standard) protect any danger areas against mechanical movement Risks, such as crushing, dragging, and shearing. 17) Use of at least one indicator-light ( FAACLIGHT ) is recommended for every system, as well as a warning sign adequately secured to the frame structure, in addition to the devices mentioned at point 16 . 18) FAAC declines all liability as concerns safety and efficient operation of the automated system, if system components not produced by FAAC are used. 19) For maintenance, strictly use original parts by FAAC. 20) Do not in any way modify the components of the automated sys-tem.

7 21) The installer shall supply all information concerning manual operation of the system in case of an emergency and shall hand over to the user the warnings handbook supplied with the product. 22) Do not allow children or adults to stay near the product while it is operating. 23) Keep remote controls or other pulse generators away from children, to prevent the automated system from being activated involuntarily. 24) Transit is permitted only when the automated system is idle. 25) The user must not attempt any kind of repair or direct action whatever and contact qualified personnel only. 26) Check at least every 6 months the efficiency of the system, particularly the efficiency of the safety devices (including, where foreseen, the operator thrust force) and of the release devices.

8 27) Anything not expressly specified in these instructions is not FOR THE INSTALLERGENERAL SAFETY OBLIGATIONSENGLISH3 1. WARNINGS Attention: Before attempting any work on the control unit (connections, maintenance), always turn off Install, upstream of the system, a differential thermal breaker with adequate tripping Connect the earth cable to the terminal on the J9 connector of the unit (see ).- Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.). To avoid any electrical noise, use separate sheaths or a screened cable (with the screen earthed).CONTROL UNIT 624 BLD 3. LAYOUT AND COMPONENTS OF 624 BLDP ower supply voltage *230 V~ (+6% -10%) - 50/60 Hzor115 V~ (+6% -10%) - 50/60 HzAbsorbed power7 WMotor max.

9 Load1000 WPower supply for accessories24 VdcAccessories mAOperating ambient temperaturefrom -20 C to +55 CProtectionfuses *F1 = F 10A - 250V F2 = T 0,8A - 250 VorF1 = F 20A - 120V F2 = T 0,8A - 120 VWork timeProgrammable (from 0 to 4 minutes)Pause timeProgrammable (from 0 to 4 minutes)Motor powerProgrammable on 50 levelsProgramming3 programming levels for greater flexibility of useRapid connectorCoupling for 5-pin Minidec board, Decoder, Receiver RP/RP2 Programmableoutputs4 programmable outputsin 18 different functionsFeaturesManagement of slow-downs, multifunction display, BUS technology and INTEGRATED METALLIC MASS DETECTOR* The power supply voltage and fuses depend on the version purchased 2. TECHNICAL DESCRIPTION OF COMPONENTSDLSIGNALS AND PROGRAMMING DISPLAYLEDINPUT STATUS CONTROL LEDsJ1 LOW-VOLTAGE TERMINAL BOARDJ2 TERMINAL BOARD FOR CONNECTION OF MOTOR, FLASHING LAMP AND FANJ3 OPENING LIMIT-SWITCH CONNECTORJ4 CONNECTOR FOR DECODER MINIDEC / RP RECEIVERJ5 CLOSING LIMIT-SWITCH CONNECTORJ6 CONNECTOR FOR ROD BREAKING SENSORJ8 CONNECTOR FOR MOTOR THRUST CAPACITORJ9 TERMINAL-BOARD FOR 230 VAC POWER SUPPLYDS1 LOOP 1 and LOOP 2 FREQUENCIES SELECTORF1 FUSE FOR MOTORS AND TRANSFORMER PRIMARY WINDING (F 5A)F2 FUSE FOR LOW VOLTAGE AND ACCESSORIES (T 800mA)FPROGRAMMING PUSH-BUTTON F +PROGRAMMING PUSH-BUTTON + -PROGRAMMING PUSH-BUTTON - TF1 TRANSFORMERFig.

10 1 ENGLISH4 4. ELECTRICAL CONNECTIONSTo connect the photocells and safety devices, consult paragraph BLUEMOTOR THRUSTCAPACITORFANMOTORBEAM BREAKERFig. 2 LOOP 1 - Magnetic loop LOOP 1 (OPEN - terminals 1-2): it activates the OPENING functionLOOP 2 - Magnetic loop LOOP 2 (SAFETY/CLOSE - terminals 3-4): it activates the SAFETY/CLOSING function OPEN - Opening Command ( - terminal 5): this refers to any pulse generator ( : push-button) which, by closing a contact, commands the barrier to close and/or - Closing Command ( - terminal 6): this refers to any pulse generator ( : push-button) which, by closing a contact, commands the barrier to - Closing safety-devices contact ( - terminal 7). The purpose of the closing safety devices is to protect the barrier movement area during closure, by reversing motion.


Related search queries