Example: bachelor of science

A&D Titel Gleichstrommotoren - opis.cz

DC motorsSizes 100 to kW to 1610 kWCatalog DA 12 2004dc motorsCatalogs for "Large Drives"SINAMICS G150 Drive ConverterCabinet Units 75 kW to 560 kWOrder No.:German: E86060-K5511-A101-A2 English: E86060-K5511-A101-A2-7600D 11DC Motors Sizes 100 to 630 kW to 1610 kWOrder No.:German: E86060-K5312-A101-A1 English: E20002-K5312-A101-A1-7600DA 12 SIMOREG DC-MASTER 6RA70 Digital Chassis ConvertersDA No.:German: E86060-K5121-A111-A1 English: E86060-K5121-A111-A1-7600 French: E86060-K5121-A111-A1-7700 SIMOREG K 6RA22 Analog Chassis ConvertersOrder No.:German: E86060-K4021-A121-A1 English: E86060-K4021-A121-A1-7600DA Parts for SIMOREGC hassis 21 ESIMOREG DC MASTER 6RM70 Digital Converter Cabinet UnitsOrder No.

Welcome to Automation and Drives 1/2 Siemens DA 12 · 2004 We would like to welcome you to Automation and Drives and our comprehensive range of products, systems, solutions and services for

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of A&D Titel Gleichstrommotoren - opis.cz

1 DC motorsSizes 100 to kW to 1610 kWCatalog DA 12 2004dc motorsCatalogs for "Large Drives"SINAMICS G150 Drive ConverterCabinet Units 75 kW to 560 kWOrder No.:German: E86060-K5511-A101-A2 English: E86060-K5511-A101-A2-7600D 11DC Motors Sizes 100 to 630 kW to 1610 kWOrder No.:German: E86060-K5312-A101-A1 English: E20002-K5312-A101-A1-7600DA 12 SIMOREG DC-MASTER 6RA70 Digital Chassis ConvertersDA No.:German: E86060-K5121-A111-A1 English: E86060-K5121-A111-A1-7600 French: E86060-K5121-A111-A1-7700 SIMOREG K 6RA22 Analog Chassis ConvertersOrder No.:German: E86060-K4021-A121-A1 English: E86060-K4021-A121-A1-7600DA Parts for SIMOREGC hassis 21 ESIMOREG DC MASTER 6RM70 Digital Converter Cabinet UnitsOrder No.

2 :German: E86060-K5122-A101-A1 English: E86060-K5122-A101-A1-7600DA 22 SIMOVERT MV Medium-VoltageDrives 660 kVA to 7200 kVAOrder No.:German: E86060-K5363-A101-A2 English: E86060-K5363-A101-A2-7600DA 63 Components for AutomationOrder No.:German: E86060-D4001-A100-C1 English: E86060-D4001-A110-C1-7600CA 01A&D designations marked in this Product Brief with are registered trademarks of Siemens designations used in this document may be trade-marks; the owner's rights may be violated if they are used by third parties for their own :Catalog DA 12 1995/96 Supplement DA 12 July 2001 Siemens AG 2004DC motors Sizes 100 to kW to 1610 kWCatalog DA 12 2004 IntroductionWelcome to Automation and DrivesDC technology remains of prime importanceDC motors For what types of applications?

3 Why use DC motors from Siemens?1 Explanations2 Selection and orderingGuidelineOrder No. codeOrder No. supplementsSelection and ordering dataOptions3 Dimensions4 AppendixRegulations, standards and specificationsSiemens contact part-ners worldwideA&D online servicesCustomer supportIndicesConditions of sale and delivery5 The products and sys-tems described in this catalog are manufactu-red under application of a quality management system certified by DQS in accordance with EN ISO 9001 (Cer-tificate Registration No. 002241 QM UM).The certificate is recog-nized in all IQ Net toAutomation and DrivesSiemens DA 12 20041/2We would like to welcome you to Automationand Drives and our comprehensive range ofproducts, systems, solutions and services forproduction and process automation andbuilding technology Totally Integrated Automation andTotally Integrated Power, we deliver solutionplatforms based on standards that offer youa considerable savings the world of our technology now.

4 Ifyou need more detailed information, pleasecontact one of your regional Siemenspartners. They will be glad to assist DA 12 2004 even if its immediate demise has been forecast for more than fifteen years: Siemens Automation & Drives will continue to provide this simple and user-friendly technology into the future. After all, it has proved itself to be reliable in daily use for decades and therefore re-mains of prime our extensive know-how and with more than 125 years of experience, we remain your reliable partner for all your DC drive requirements. We offer perfect up-to-date solutions for both new plants or retrofitting. We are constantly working on the further development of the DC technology.

5 The perfect example: SIMOREG Control Module, the perfect retrofit solution for your DC drives and the most effective method to safeguard your investments values endure DC technologyremains of prime importance1/4 Siemens DA 12 2004 The modular DC motors are well-proven in combination with static converters as variable-speed drives in almost all industry secures competitive strength and efficiency internationally as DC drives are the optimum solution, no matter which functions have to be fulfilled in drive, power or process example: In elevators and cable cars In rolling mills In the printing industry In the textile and man-made fiber industries For hoisting equipment In the basic industriesDC motors For what types of application?

6 1/5 Siemens DA 12 2004 Siemens DC drives distinguish themselves as follows: Their excellent static and dynamic control response Their wide range with high control precision The high efficiency of the complete drive motors continue to be a high-quality alternative to three-phase with SIMOREG drive converters, they form optimum, variable-speed drives for numerous branches of industry and are used wherever there is a requirement for favorably priced technology and high features: High power density with small motor dimensions High thermal reserves for continuous duty and overload thanks to the DURIGNIT 2000 insulating system Minimal losses thanks to excellent efficiency High quality of smooth running and vibration Low noise values High mechanical rigidity Low weight Long brush lifetimes thanks to optimized commutation system High operational reliability and availability thanks to numerous diagnostic functions when fed from SIMOREG drive use DC motors from Siemens?

7 1/6 Siemens DA 12 2004 Siemens DA 12 200422/2 Motor design2/2 Magnetic circuit, rate of change of current2/2 Rotors2/2 Carbon brushes, commutation2/2 Supply, converter connection, armature voltage and smoothing reactor2/2 Installation and operating conditions2/3 Intermittent duty2/3 DURIGNIT 2000 insulating system2/3 Rated power2/3 Direction of rotation2/3 Field control range2/3 Speed data on the rating plate2/3 Sector-specific applications2/3 Paint finish2/3 Aggressive gases and vapors2/4 Noise levels2/4 Bearings2/4 Cooling and ventilation2/5 Encoders2/5 Protection and monitoring2/6 Terminal boxes2/6 Shaft ends2/6 BalancingExplanationsSiemens DA 12 20042/2 Explanations 2 Motor designAll DC motors are fully laminated and, up to and including Size 280, they are uncompensated.

8 From Size 355, the motors are equipped with a compensation winding. At constant torque, the forced-cooled motors 1GH, 1GG, 1GF, 1HQ and 1HS can be coasted down to 10 rpm by means of armature self-ventilated 1HA motors can be coasted down when the torque falls by means of armature control 1:3. At constant torque, the non-ventilated 1HC motors can be coasted down to approximately 50 rpm by means of armature circuit, rate of change of currentThe motors have a fully laminated magnetic circuit and are there-fore suitable for being fed from converter units. In the case of dy-namic processes, a rate of change of current up to 250IN/s is laminated rotor packages have screwed slots to minimize noise and torque ripple.

9 The rotors are dynamically brushes, commutationPractically spark-free commutation when fed from drive convert-ers is achieved as a result of the optimum motor design, even in the overload range. This results in extremely long brush wear is essentially dependent on the operating and ambi-ent conditions of the DC motor, so the following conditions should apply in order to achieve a long brush lifetime: Relative air humidity 10 to 50% Effective load > 50% IN Cooling air temperature > 10 CFor conditions outside these ranges, information is available on applications can also be mastered if the appropriate brush materials are , converter connection, armature voltage and smoothing reactorThe rated voltages listed in the selection tables are rated volt-ages according to DIN 40 rated data assigned to each of these rated voltages is only valid in combination with the specified converter connection and supply voltage.

10 The inductances specified in the "Selection and ordering data" tables are applicable for 100 Hz with single-phase and for 300 Hz with three-phase bridge connections and a line frequency of 50 Hz, which is generally specified on the rating and operating conditionsOperating conditionsThe motors are designed for the following conditions of operation: Site altitude 1000 m (> 1000 m, see adjacent characteristics) Cooling air temperature up to 40 C (> 40 C, see adjacent characteristics) Cooling air must not contain any foreign bodies or aggressive components Maximum permissible vibration levels (see adjacent table). Output changes as a function of the site altitude and the coolant supply temperature for DC deviations as a function of the site altitude and the coolant supply temperature for DC there is a risk of condensation, anti-condensation heating can be fitted to the motors.


Related search queries