Example: marketing

A11 Series Low Temperature Cutout Controls …

Refer to the QuickLIT website for the most up-to-date version of this Series Low Temperature Cutout Controls product BulletinA11 Series low Temperature Cutout Controls are available with Single-Pole, Single-Throw (SPST) or Single-Pole, Double-Throw (SPDT) contact action. Typical applications include the sensing of low Temperature conditions to avoid over cooling or icing of hydronic coils, cooling coils, and liquid-handing pipes. The Controls are compact and sturdy, and have an adjustable Temperature setpoint range with a fixed differential. The range adjustment screw is accessible at the bottom of the control , and at the top of the control when the cover is removed.

A11 Series Low Temperature Cutout Controls Product Bulletin 3 Ordering Information Table 3 describes the A11 Series Low Temperature Cutout Control models.

Tags:

  Information, Product, Control, Temperatures, Bulletin, Low temperature cutout controls, Cutout, Low temperature cutout controls product bulletin

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of A11 Series Low Temperature Cutout Controls …

1 Refer to the QuickLIT website for the most up-to-date version of this Series Low Temperature Cutout Controls product BulletinA11 Series low Temperature Cutout Controls are available with Single-Pole, Single-Throw (SPST) or Single-Pole, Double-Throw (SPDT) contact action. Typical applications include the sensing of low Temperature conditions to avoid over cooling or icing of hydronic coils, cooling coils, and liquid-handing pipes. The Controls are compact and sturdy, and have an adjustable Temperature setpoint range with a fixed differential. The range adjustment screw is accessible at the bottom of the control , and at the top of the control when the cover is removed.

2 Figure 1: A11 Series Low Temperature Cutout ControlTable 1: Features and BenefitsFeaturesBenefitsPrecision Repeat AccuracyRemains unaffected by ambient Temperature at the control diaphragm cup and 4 ft ( m) capillary (20 ft [ m] sensing bulb must be in the controlled area).Trip-Free Manual ResetAllows the lever to reset. You must press and release the lever before operation Snap-Acting Contacts in a Dust Protected EnclosureEnables the A11 to operate to the fullest Reading ScaleProvides easy to adjust setpoint. Adjustments can be made from the top or bottom of the Series Low Temperature Cutout ControlsProduct BulletinA11A, A11B, A11D, A11 ECode No.

3 LIT-125010 Issued April 2018A11 Series Low Temperature Cutout Controls product Bulletin2 OverviewThe A11 Controls are compact and sturdy and feature an adjustable range with a fixed differential. The range adjustment screw is accessible at the bottom of the control or at the top, when the cover is removed. A factory-set low Temperature stop is available when 2 shows the A11 dimensions. Figure 2 describes the A11 electrical ratings. Table 2: Electrical RatingMotor Rating120 V208 V240 VMotor DescriptionAC Full Load Locked Rotor Duty - 125 VA, 24 to 277 Mounting 2: A11 Series Low Temperature Cutout Controls Dimensions, in.

4 (mm)A11 Series Low Temperature Cutout Controls product Bulletin3 Ordering InformationTable 3 describes the A11 Series Low Temperature Cutout control models. When ordering an A11 Series Low Temperature Cutout control :1. Specify the product Specify the low Temperature Cutout stop setting, if and ReplacementsIf the A11 Series Low Temperature Cutout control fails to operate within its specifications, replace the unit. Contact your nearest Johnson Controls Specifications Table 3: A11 ModelsModelDescriptionA11 ASingle-Pole, Single-Throw (SPST), Open Low, Manual ResetA11 BSPST, Open Low, Automatic RecycleA11 DSingle-Pole, Double Throw (SPDT), Manual ResetA11 ESPDT, Automatic RecycleA11 Low Temperature Cutout ControlsProduct CodesA11A: SPST, Open Low, Manual ResetA11B: SPST, Open Low, Automatic RecycleA11D: SPDT, Manual ResetA11E: SPDT, Automatic RecycleRange Cutout35 to 45 F (2 to 7 C)DifferentialA11A and A11D: Temperature must be 12 F ( C) above Cutout point before control can be and A11E.

5 12 F ( C)Ambient TemperatureMinimum: 0 F (-18 C)Maximum: 140 F (60 C)Maximum Temperature at Bulb250 F (121 C)Sensing Element1/8 in. x 20 ft ( mm x m) or 1/8 in. x 40 ft ( mm x m)Capillary Length4 ft ( m)SwitchSnap-acting contacts in dust-protected enclosureMaterialCase: ( mm) Cold Rolled SteelCover: in. ( mm) Cold Rolled SteelFinishGalvanized SteelConduit Opening22 mm ( in.) hole for mm (1/2 in.) conduitMounting BracketStandard on all controlsShipping WeightIndividual Pack: lb ( kg)Overpack of 20 Units: 38 lb (17 kg)Electrical RatingPilot Duty: 125 VA, 24 to 277 VACM otor RatingsAC Full Load Ampere: 120 V = A, 208 V = A, 240 V = AAC Locked Rotor Ampere: 120 V = A, 208 V = A, 240 V = ANon-Inductive Ampere: 120 V = A, 208 V = A, 240 V = APublished in Series Low Temperature Cutout Controls product Bulletin4 Johnson Controls and PENN are registered trademarks of Johnson Controls in theUnited States of America and/or other countries.

6 All other trademarks used herein are the propertyof their respective owners. Copyright 2018 by Johnson Controls . All rights Technologies & Solutions507 E. Michigan Street, Milwaukee, WI 53202 ComplianceUnited StatesUL Listed, File SA516, SDFYFCC Compliant to CFR 47, Part 15 Subpart B, Class ACanadaUL Listed, CSA Class No. 1222 01, File LR948 Industry Canada, ICES-003 The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls , Inc. shall not be liable for damages resulting from misapplication or misuse of its Low Temperature Cutout Controls