Example: marketing

Adaptive Power Module SPEC (369583)

Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller Adaptive Power Module 369583f 1 The Adaptive Power Module family is a group of modular products for the control of permanently installed lighting 800 W Max 500 W Max 500 W Max 500 W Max fixtures. This document describes the following product: CCI. Zone 1 Zone 2 Zone 3 Zone 4. Adaptive Power Module (model LQSE-4A-D). Option DIN Rail Power Module Input Def H. LQSE-4A-D. Hi Temp Opt1 M. Prog Opt2 L. Features Power Opt3. 230 V~ 50 / 60 Hz 10 A +44.(0) Adaptive Power Modules can be used in a HomeWorks QS system.

•nternal relay provides an air gap off when all zones I are off. • One load type per zone. • Output must not be used to control receptacles, including plug-in lamps. • Output must be directly connected to the load. Output breakers or switches must not be used. • Run a separate neutral for each load circuit. A

Tags:

  Control, Early, Output

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Adaptive Power Module SPEC (369583)

1 Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller Adaptive Power Module 369583f 1 The Adaptive Power Module family is a group of modular products for the control of permanently installed lighting 800 W Max 500 W Max 500 W Max 500 W Max fixtures. This document describes the following product: CCI. Zone 1 Zone 2 Zone 3 Zone 4. Adaptive Power Module (model LQSE-4A-D). Option DIN Rail Power Module Input Def H. LQSE-4A-D. Hi Temp Opt1 M. Prog Opt2 L. Features Power Opt3. 230 V~ 50 / 60 Hz 10 A +44.(0) Adaptive Power Modules can be used in a HomeWorks QS system.

2 An auto-detect mode is available to detect and LQSE-4A-D. configure leading edge or trailing edge dimming for incandescent/halogen, electronic/magnetic low voltage RTISS-TE operates on the trailing edge of the AC. and neon / cold cathode light sources. sine wave. This allows for true instantaneous voltage Controls dimmable CFL / LED loads. Refer to Lutron compensation. P/N 048478 on for compatibility with Unit is 12 DIN modules (216 mm) wide. dimmable CFL / LED light sources. Provides air gap off (when all zones are off). RTISS Equipped technology compensates for incoming LEDs on front of unit provide diagnostic information.

3 Line-voltage variations (up to 2% change in frequency / Includes QS link for seamless integration of lights second) such as changes in Root Mean Square (RMS) and controls. voltage, frequency shifts, harmonics and line noise. System Example Emergency Contact Closure Input HomeWorks QS HomeWorks Power Module QS Panel QS Contact seeTouch Closure QS Wallstation Interface GRAFIK. CCI QS Zone 1 Zone 2 Zone 3 Zone 4. Eye QS. COM. COM. MUX. MUX. Zones CCI. 0,5 N m 0-10 V- All Others 50 mA. Input Def H. Z096. Hi Temp 0-10 V Power Module Opt1. Option M. Program LQSE-4T10-D Opt2.

4 230 V~ 50/60 Hz 50 mA Up Power +44.(0) Opt3 L. 1,2 N m L N 8 mm Mains Only Outputs 230 V~ 10 AX each 1 2 3 4. Adaptive Power Up to 100. Module QS Link total QS. devices 800 W Max 500 W Max 500 W Max 500 W Max CCI. Zone 1 Zone 2 Zone 3 Zone 4. Option DIN Rail Power Module Input Def H. LQSE-4A-D. Hi Temp Opt1 M. Prog Opt2 L. Power Opt3. 230 V~ 50 / 60 Hz 10 A +44.(0) 220 240 V~ control Power 800 W Adaptive load1. 500 W Adaptive load1. 500 W Adaptive load1. 500 W Adaptive load1. Notes: 1. See " output Zone Ratings" in Specifications section, for specific load types ratings.

5 S P E C I F I C AT I O N S U B M I T TA L Page 1. Job Name: Model Numbers: Job Number: Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller 369583f 2 Specifications Adaptive Power Module output Zone Ratings (continued). Each zone has no minimum load requirement. Power When programmed to "auto" mode, the unit starts in 220 240 V~ 50/60 Hz trailing edge and if an incompatible load is detected, it 10 A maximum total input current will convert to leading edge. Lightning strike protection meets ANSI/IEEE standard Internal relay provides an air gap off when all zones Can withstand voltage surges of up to are off.

6 6 000 V and current surges of up to 3 000 A. One load type per zone. Standards output must not be used to control receptacles, RoHS Compliant including plug-in lamps. IEC/EN 60669-2-1 output must be directly connected to the load. CE marked output breakers or switches must not be used. Lutron Quality Systems registered to ISO Run a separate neutral for each load circuit. A. common neutral connection is not recommended. Environment Maximum wire length between the Energi Savr Node See Mounting on page 4 for thermal specifications unit and the load must be less than m.

7 Relative humidity: less than 90% non-condensing Unit may be powered by Ground Fault Interrupter (GFI). For indoor use only or Residual Current Circuit Breaker with Overload output Zone Ratings (RCBO) protected circuit if required. Load circuit wiring (from breaker to unit to load) must be run in its own No Derating is required if all the conditions below are met: non-metallic conduit, or nuisance tripping may occur. Calibration point maximum is 70 C. Room ambient temperature is between 0 C and 30 C For applications requiring 0 10 V- control , use Ten Panel ambient temperature is between 0 C and 50 C Volt Interface (GRX-TVI) or the LQSE-4T10-D.

8 100 W Derating is required on all zones for a single For applications requiring higher wattage ratings, use a Module in a single non-ventilated DIN enclosure if: Power booster (NGRX-PB, NGRX-ELVI, NGRX-FDBI). The room ambient temperature is between 30 C and 40 C. 200 W Derating is required on all zones for multiple row non-ventilated DIN enclosure if: T he room ambient temperature is between 30 C and 40 C. Each zone is rated for the following wattage and load typesA, B: Zone 1 Rating Zone 2, 3 and 4 Rating (per zone). Load Type 100 W 200 W 100 W 200 W. No Derating Derating Derating No Derating Derating Derating Incandescent / Halogen 800 W 700 W 600 W 500 W 400 W 300 W.

9 Electronic Low Voltage 800 W 700 W 600 W 500 W 400 W 300 W. Magnetic Low VoltageD 800 VA (600 WC) 700 VA (525 WC) 600 VA (450 WC) 500 VA (375 WC) 400 VA (300 WC) 300 VA (225 WC). Neon / Cold CathodeD 800 VA (600 WC) 700 VA (525 WC) 600 VA (450 WC) 500 VA (375 WC) 400 VA (300 WC) 300 VA (225 WC). A. Additional load type options are available in the HomeWorks QS software suite, some may require an interface. Contact Lutron for details. B. Refer to Lutron P / N 048478 on for compatibility with dimmable CFL / LED light sources. C. Actual lamp wattage. D. Only use iron core transformers intended for use with an electronic switch or dimmer per Clause of IEC / EN 60669-2-1.

10 S P E C I F I C AT I O N S U B M I T TA L Page 2. Job Name: Model Numbers: Job Number: Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller 369583f 3 Specifications (continued) Out of Box Functionality Terminals (Torque, wire gauge & type ratings) This section describes the default functionality when Mains wiring: N m the unit is first installed. mm to mm . (single wire, solid or stranded) Emergency Contact Closure Input (CCI). mm to mm When the CCI is open, the Energi Savr Node QS. (two wires, solid or stranded) unit will enter Emergency Mode, which will turn on Zone wiring: N m all loads to their emergency level and disable control mm to mm of local zones and QS devices.


Related search queries