AFFINITY SERIES SPLIT SYSTEM AIR CONDITIONERS

TECHNICAL GUIDEAFFINITYTM SERIESSPLIT SYSTEM AIR CONDITIONERS16 SEER R-410A 1 PHASE2 THRU 5 NOMINAL TONSMODELS: CZF024 THRU 060 Due to continuous product improvement, specifications are subject to change without us on the web at and rating information can be found at SUMMARY*Extended 10-Years limited parts Lifetime limited compressor parts and compressor warranties require online reg-istration within 90 days of purchase for replacement or closing fornew home construction.*Does not apply to R-22 models, 3-Phase models, or internet Limited Warranty certificate in User's Information Manual for details. 567175-YTG-H-0714 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALEDESCRIPTIONThe 16 SEER SERIES unit is the outdoor part of a versatile cli-mate SYSTEM .

567175-YTG-H-0714 Johnson Controls Unitary Products 3 PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit, the smallest matched indoor unit, and 15 feet of interconnecting line tubing.

Tags:

  Refrigerant

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of AFFINITY SERIES SPLIT SYSTEM AIR CONDITIONERS

1 TECHNICAL GUIDEAFFINITYTM SERIESSPLIT SYSTEM AIR CONDITIONERS16 SEER R-410A 1 PHASE2 THRU 5 NOMINAL TONSMODELS: CZF024 THRU 060 Due to continuous product improvement, specifications are subject to change without us on the web at and rating information can be found at SUMMARY*Extended 10-Years limited parts Lifetime limited compressor parts and compressor warranties require online reg-istration within 90 days of purchase for replacement or closing fornew home construction.*Does not apply to R-22 models, 3-Phase models, or internet Limited Warranty certificate in User's Information Manual for details. 567175-YTG-H-0714 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALEDESCRIPTIONThe 16 SEER SERIES unit is the outdoor part of a versatile cli-mate SYSTEM .

2 It is designed with a matching indoor coil compo-nent from Johnson Controls Unitary Products. Available fortypical applications, this climate SYSTEM is supported withaccessories and documents to serve specific Superior Coil Protection - A stamped, decorative metal coilguard protects the microchannel coil from debris and otherdamaging material. Protected Compressor - The compressor is safeguardedagainst abnormal pressures and temperatures by an internalpressure relief valve, an internal temperature sensor, andfactory high and low pressure SYSTEM controls. A factoryinstalled liquid line filter-drier further protects the compressoragainst moisture and debris.

3 Environmentally Friendly refrigerant - The next genera-tion refrigerant R-410A delivers environmentally friendly per-formance with zero ozone depletion. Durable Finish - An automotive quality finish provides theultimate protection from harmful UV rays and rust creep,ensuring a long-lasting, high quality appearance. A powder-paint topcoat is applied over a baked-on primer using a gal-vanized, zinc coated steel base material. The result is a fin-ish that has been proven in testing to provide 33% greaterdurability than conventional powder-coat finishes. QuietDrive SYSTEM - Features combination of swept-wingfan, composite base pan, isolated compressor compartment,and single-stage compressor to reduce overall sound to amere whisper.

4 Low RPM Fan Motor - Helps to reduce airflow noise. Swept Wing Fan - A fan design boasting technologyadapted from aeronautic and defense engineering providesfor whisper-quiet operation by allowing air to flow smoothlyand efficiently across the fan tips. Composite Base Pan - The strong and durable compositebase pan provides added strength while resisting rust andcorrosion, as well as reducing sound and vibration. Isolated Compressor Compartment - A molded compositebulkhead isolates the refrigeration components and the com-pressor from the rest of the unit, reducing sound and vibra-tion. Lower Installed Cost - Designed to provide enhancedinstallability by featuring a slide-down control compartmentthat allows easy access to control components, along withangled service valves to reduce overall installation time andcost.

5 Factory charged for a 15 foot lineset. Factory Installed Filter-Drier - A factory installed, solid coreliquid line filter-drier removes harmful debris and moisturefrom the SYSTEM . Easy Service Access - A full end, full service access panelwith handle makes for easy entry to internal components. Communications Capable - Requiring only a simple 4-wireinstallation, the communicating capability enables the use ofthe Touch Screen Communicating Control, allowing real timevisibility of SYSTEM operation and the use of diagnostic fea-tures, while still maintaining the ability to function with a tradi-tional thermostat. Premium SYSTEM Warranty* - Limited lifetime compressorwarranty when registered online within 90 days of installa-tion.

6 Agency Listed - Safety certified by CSA to UL 1995 / Performance certified to ANSI/AHRI Standard 210/240in accordance with the Unitary Small Equipment Controls Unitary Products* Adapter fitting must be field installed for the required 1-1/8 line dimensions are in inches and are subject to change without height is from bottom of basepan to top of fan length and width include screw and Electrical DataMODELCZF02413(C)CZF03013(C)CZF03614( C)CZF04213(C)CZF04814(C)CZF06013(C)Unit Supply Voltage208-230V, 1 60 HzNormal Voltage Range 1187 to 252 Minimum Circuit Overcurrent Device Amps 2303030404550 Min. Overcurrent Device Amps 3202020253040 Compressor AmpsTypeScroll Scroll Scroll Scroll Scroll Scroll Rated Rotor587377112109135 Crankcase HeaterNo No No No No No Factory External Discharge MufflerNoNoNoNoNoNoFactory External Check ValveNoNoNoNoNoNoHS Kit Required with TXV 4 NoNoNoNoNoNoFan Diameter Inches222222222424 Fan MotorRated HP1/151/151/41/41/41/3 Rated Load RPM850850850850850915 Nominal CFM202020503250330038003900 CoilFace Area Sq.

7 Deep111111 Fins / Inch232323232323 Liquid Line Set OD (Field Installed)3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed)3/4 3/4 3/4 7/8 7/8 1-1/8*Unit Charge (Lbs. - Oz.) 53 - 124 - 65 - 116 - 47 - 56 -14 Charge Per Foot, Weight Rated in accordance with AHRI Standard 110-2012, utilization range A .2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant , using the difference in actual lineset length (not equivalent length) multiplied by the per foot (Inches) refrigerant ConnectionService Valve SizeABCL iquidVapor243037313/83/43030373136403731 424037317/8484042-1/434604042-1/4347/8*5 67175-YTG-H-0714 Johnson Controls Unitary Products3 PROCEDURES:1.

8 Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit, the smallest matched indoor unit, and 15 feet of interconnecting line Verify the TXV and additional charge required for specific matched indoor unit in the SYSTEM using the above Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data For indoor matches requiring additional charge, the refrigerant needs to be weighed in for specific matched indoor unit and actual lineset Permanently mark the unit nameplate with the total SYSTEM charge. Total SYSTEM Charge = Base Charge (as shipped) + charge adder for matched indoor unit + charge adder for actual lineset Charge for Various Matched SystemsOutdoor Unit CZF02413(C)CZF03013(C)CZF03614(C)CZF0421 3(C)CZF04814(C)CZF06013(C)

9 Required TXV 1,24F14F14N14N14N14H1 Indoor Unit 3,4,5 Additional Charge, OzAHE24B9 AHE30B90 AHE36C1560 AHE42D 933 AHE48D 13774 AHE60D 121294 AHR24B9 AHR30B 0 AHR36B 60 AHR42C 33 AHR48D 74 AHR60D 1294 AHV24B9 AHV30B90 AHV36C1660 AHV42D 16108 AHV48D 1074 AHV60D 1292FC/MC/PC3290 FC/MC/PC3590 FC/MC/PC371560 FC/MC/PC4315600 FC/MC/PC48 9330 FC/MC/PC60 137740FC/MC62 121294FC64 18181511HD48 33 HD60 774 UC48 9322 UC60 137750 Some of the combinations shown in the above SYSTEM Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil only matches, please see the COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils :1.

10 For applications requiring a TXV use S1-1 TVM** SERIES A TXV kit must be used with these indoor units to obtain SYSTEM Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal Refer to Cooling Performance Data tables for actual SYSTEM performance for specified SYSTEM Controls Unitary ProductsCOOLING CAPACITY - With Air Handler CoilsUNITMODELAIR HANDLERCOIL MODEL1 COOLINGMODELWIDTHRATEDCFMNET SEER AC WITH AIR HANDLERSCZF02413(C) (C) (C) Notes See Page Controls Unitary Products5 CZF03614(C) (C) (C) Notes See Page CAPACITY - With Air Handler Coils (Continued)