Agilent 34401A 6 ½ Digit Multimeter - University of Michigan
ment and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number 34401-90004 Edition Seventh Edition. August 2007 Printed in Malaysia Agilent Technologies, Inc. 3501 Stevens Creek Blvd. Santa Clara, CA 95052 USA Microsoft® and Windows® are U.S. regis-
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
The Franck-Hertz Experiment - University of Michigan
instructor.physics.lsa.umich.eduJan 30, 2006 · The Franck-Hertz Experiment The Franck-Hertz experiment, first undertaken shortly after Bohr’s theory of the atom was pre-sented, provided one of the early indications that atoms had discrete energy levels. In this ex-periment, electrons are accelerated and pass through mercury vapor, where they lose energy by
Electron Diffraction and Crystal Structure
instructor.physics.lsa.umich.eduThe electron diffraction tube is a small cathode ray tube (CRT) similar to that in a small (old-fashioned) TV set. The electrons pass through a target that consists of graphite, only a few molecular layers thick, vapor-deposited on a micromesh nickel grid. The target is crystalline in …
Structure, Crystal, Electron, Diffraction, Electron diffraction and crystal structure
Mass Spectrometry: Quadrupole Mass Filter Mass ...
instructor.physics.lsa.umich.eduQuadrupole mass filter Successful path Detector X Y Fig. 2: Schematic of a quadrupole mass filter. A quadrupole mass spectrometer consists of an ionizer (bombardment by electrons from a hot filament), an ion accelerator, and a mass filter consisting of four parallel metal rods arranged as in the figure above.
X-ray Spectroscopy
instructor.physics.lsa.umich.eduRequired reading: Haken & Wolf, Chapter 18. Recommended: Eisberg & Resnick 9.8; McGervey 4.1 2.1 Energetic electronic transitions In the simplest model of electronic transitions in hydrogen-like atoms, an electron loses energy by moving between states with principle quantum numbers n initial and n final, and a photon is emitted with energy E ...
Chapter 4 Polarization - Instructor.physics.lsa.umich.edu
instructor.physics.lsa.umich.edubeen performed by measuring correlations of the polarization of photons from atomic transitions. This is beyond the scope of these experiments, but it's good to keep in mind that some of nature's thornier problems are lurking in the corners. Electromagnetic waves are the solutions of Maxwell’s equations in a vacuum: t t!! #"=!! #"=$ #%= #%= E ...
Related documents
1260 - Agilent
www.agilent.comAgilent also offers comprehensive instrument and enterprise services as well as a full curriculum of Agilent University learning solutions to maximize uptime, simplify administration and protect the investments in your laboratory. Through preventive maintenance, our …
Experiment 6: Frequency Modulation (FM), Generation and ...
wwwusers.ts.infn.itThe University of Michigan rebeiz@engin.umich.edu Equipment Required • Agilent E3631A Triple output DC power supply • Agilent 33120A Function Generator • Agilent 34401A Multimeter • Written for Agilent 54645A Oscilloscope (could substitute 54622A Oscilloscope) • 6.1 Treble Tone Control Amplifier: 1.0 Frequency Modulation
Advanced Design System Quick Start
edadownload.software.keysight.comBuchanan at Agilent Inc. at brian_buchanan@agilent.com for more information. The HiSIM_HV source code, and all copyrights, trade secrets or other intellectual property rights in and to the source code, is owned by Hiroshima University and/or STARC. Errata The ADS product may contain references to "HP" or "HPEESOF" such as in file
System, Design, University, Advanced, Agilent, Advanced design system
Series and Parallel Resonance - Rutgers University
www.ece.rutgers.eduDec 16, 2005 · HP 54600A or Agilent 54622A Oscilloscope Protek Model B-845 Digital Multimeter LS-400A Inductance Substituter Box 620 Ω Resistor 0.1 µF Capacitor Breadboard Other circuit elements to be determined by the students. 4.1 Series Resonance Any function generator used has internal resistance. Also, the inductor has internal resistance.
Frequency Response of Filters - Rutgers University
www.ece.rutgers.eduDec 16, 2005 · HP 54600A or Agilent 54622A Oscilloscope 2: 620 Ω, 2: 1 KΩ, 2: 2KΩ, 2: 2.2KΩ, 20 KΩ Resistors 0.05 µF, 3: 0.1 µF, 0.01 µF Capacitors 741 Op-Amp Protoboard 4.1 Low Pass Filter Build the low pass filter circuit shown in fig. 7. Apply a sinusoidal input of amplitude 1V rms and display both input and output on the scope. V s ++--+ V0 +-2 ...
EECS 100/43 Lab 2 – Function Generator and Oscilloscope
inst.eecs.berkeley.eduUniversity of California, Berkeley Department of EECS Figure 3. Sine wave Vpp and DC offset When the function generator is turned on, it outputs a sine wave at 1 kHz with amplitude of 100 mV PP (figure 4). Figure 4. Function generator has been turned on You must specify the characteristics of the signal you need. For example, to set the
Instrumentation and Equipment List
www.tnstate.eduUV-Vis Spectrometer, “Cary -100” (Agilent) with “Labsphere DRA -CA-3300” accessory: Measurement of absorbance in Ultraviolet and Visible range of . electromagnetic radiation allows for quantitative analysis of some organic . compounds, anions and metal ions. The DRA accessory provides the means of