Example: biology

AIRE-VOLVE INTERNAL & EXTERNAL TWIN FANS

2016 ErPCOMPLIANTAIRE-VOLVEINTERNAL & EXTERNAL twin FANSFOR THE COMPLETE VENTILATIONSOLUTION2029 2085 8200 Nuaire is a world leader in the development and manufactureof ventilation products and solutions. With roots stretchingback to the 1930s and a tradition of excellence in ventilationsince 1963, the Nuaire name has been at the forefront of theindustry for more than 40 is renowned worldwide for its expertise, commitment to innovation and the outstanding qualityof its products and customer service. People are at the heart of Nuaire, and the company has over 450highly committed staff dedicated to customer satisfaction. These include leading experts who are constantly setting new standards for the industry by developing new, innovative products in the company s research and development department the largest and most advanced in the was the first fan manufacturer in the world to achieve the quality standard ISO 9001, andits commitment to quality remains embedded in all aspects of its its roots in fans and mechanical ventilation products, Nuaire has progressively expanded its rangeand extended its capabilities to encompass all technologies and levels of ventilation solutions.

2016 erp compliant aire-volveinternal & external twin fans for the complete ventilationsolution

Tags:

  Aire, Twin, Fans, External, External twin fans

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of AIRE-VOLVE INTERNAL & EXTERNAL TWIN FANS

1 2016 ErPCOMPLIANTAIRE-VOLVEINTERNAL & EXTERNAL twin FANSFOR THE COMPLETE VENTILATIONSOLUTION2029 2085 8200 Nuaire is a world leader in the development and manufactureof ventilation products and solutions. With roots stretchingback to the 1930s and a tradition of excellence in ventilationsince 1963, the Nuaire name has been at the forefront of theindustry for more than 40 is renowned worldwide for its expertise, commitment to innovation and the outstanding qualityof its products and customer service. People are at the heart of Nuaire, and the company has over 450highly committed staff dedicated to customer satisfaction. These include leading experts who are constantly setting new standards for the industry by developing new, innovative products in the company s research and development department the largest and most advanced in the was the first fan manufacturer in the world to achieve the quality standard ISO 9001, andits commitment to quality remains embedded in all aspects of its its roots in fans and mechanical ventilation products, Nuaire has progressively expanded its rangeand extended its capabilities to encompass all technologies and levels of ventilation solutions.

2 Nuaire are the only company able to deliver the total ventilation solution for the built S MISSIONTO DELIVER EXCELLENCE IN EVERYTHINGWE DO AND TO ALWAYS EXCEED CUSTOMER S FANSA UNIQUE INNOVATION IN FAN DESIGNAs the inventor and market leader in twin fans , Nuaire s experience and expertise has ensured the very best solution is twin fans represent Nuaire s latest innovation:PATENTED IN-LINE FAN ASSEMBLY OPTIMUM PERFORMANCE AND LOW NOISELOWEST CASE SIZE BY DUTY MEETS LATEST LEGISLATION & BUILDING REGULATIONS40 YEARS OFTWIN FANSTwin fans have been the leading product of Nuaire throughout and have been manufactured in a variety of forms both in direct and belt driven versions, 3Ph and 1Ph. NOTE: Only INTERNAL fans can be mounted in any 2085 82002016 ErPCOMPLIANTACHIEVES 2010 BUILDING REGSLATEST EC MOTOR TECHNOLOGYG uarantees longer life and lower IN ECOSMART CONTROLSE nergy efficient demand control ventilation PRESSURE OPTIONI mproves the energy performance of the overallbuilding and guarantees lower energy costs forend CURRENT LEGISLATION AND BUILDING REGULATIONS Lower energy consumption and better SBEM NOISEDOUBLE WALLED PANEL WITH 35 MMACOUSTIC LININGE nsures lowest : EXTERNAL units X and R are not fullyacoustic lined as FROM CORROSION RESISTANT ALUZINCL onger life expectancy than other ENCLOSED FAN SPIGOTFan and matching silencer system reduces breakoutand guarantees a superior acoustic L2 LEAKAGEU nits are tested to meet Class L2 leakage.

3 (BS EN 1886 : 2007).UNIQUE INTELLIGENT DESIGN PRACTICEINNOVATIVE NEW FAN DESIGNIn-line fan assembly provides optimum performance in a minimum HOUR AUTO CHANGEOVERG uarantees ventilation 24/7 in event offan/motor failure and extends life of PRE-PROGRAMMED SOFT START FUNCTIONH elps prevent electrical overloading and minimises mechanical UNITS ARE DESIGNED & MANUFACTUREDWITH PROCEDURES AS DEFINED IN BS EN ISO 9001 2000 Quality and reliability & EXTRACTS upply unit can be interlinked with a twin fan toprovide a controllable cost effective twin fans FEATURES & BENEFITS - ENSURES BEST PRACTICE CASE SIZE BY DUTYUNIQUE PATENTED INLINE FAN DESIGNL ower profile and reduced ACCESS PANELL owers and slides under matched silencers where applicable. ( INTERNAL units only).MOST COMPACT SIZE FOR DUTY CASE AVAILABLE ON THE MARKETI deal for applications with restricted ceiling voids and bottom access is CONTROL BOXC ontrol can be mounted on either side of unit or tosave space mounted remotely.

4 ( INTERNAL units only).UNIQUE TOP ACCESS PANELE xternal units have hinged roof for quick and easy access. *To mount vertically refer to AVT-VK kit installation and maintenance blowers are compliant to EC/327 TIMES AND MONEY ON SITEUNIQUE PATENTED DAMPER ARRANGEMENTFans to be installed horizontally, vertically, at anyangle or mounted vertically downward if FIT MATCHING SILENCERS WITH QUICKFIT CLAMP BRACKETSCan be easily incorporated into existing drop rodsupporting LENGTH ACCESS PANEL WITH SAFETYRETAINING FEATURESEasy access to motor and blower assemblies ensuresquick installation, commissioning and maintenance.( INTERNAL units only).REMOVABLE UNIT END PANELCan be attached to matched silencer prior to connection to ducting ROOF MODELI nline (X) and grille outlet options (R).MAKES LIFE EASIERWIDE DIRECT DUTY RANGEA vailable up to ALUZINC FINISHHas 5 times longer life than galvanised steel andprovides higher wear ENERGY EFFICIENCY CONTROLUp to 80% controllability allowing the duty to beadjusted if ductwork installation changes duringconstruction on IN ECOSMART CONTROLI ntegrated BMS interface as standard.

5 FULL ACCESSORY RANGEI ncludes optional end panel with rectangular or circular spigot, remote cable for mounting of control box, matched silencers and YEAR WARRANTYP eace of IN ANY ORIENTATION WITH UMBILICAL KIT*MATCHED SILENCERS ( EXTERNAL SILENCERS HAVE PITCHED ROOF) EXTERNAL VERSION WITH OR WITHOUTCONSTANT PRESSURE CONTROLFULLY RETAINED BOTTOM ACCESS PANEL( INTERNAL RANGE ONLY)HINGED ROOF ON EXTERNAL RANGE ( X & R VERSIONS) R MODULE CAN BE ORDERED SEPARATELYAND MOUNTED IN ANY ORIENTATION*6029 2085 8200 SIMPLE TO INSTALLAll controls are pre-assembled, configured and installed directly into the fan or air handling unit,this includes 3-port motorised valves and actuators, pipework, off coil thermostats and sensors, frost protection, etc. Site time kept to a minimum, quality and efficiency SYSTEMSNo need for main VCD, no wasted energy or noisegeneration because the air volume can be precisely set via the integrated speed control,minimum and maximum speeds easily adjustedvia Ecosmart commissioning , PRECISE COMMISSIONINGAs recommended in Part L, Ecosmart enables thesystem to be accurately commissioned via an integrated speed control, minimum and maximum speeds easily adjusted via commissioning panel integral to the SYSTEMSWith Ecosmart your system is only at maximumdesign duty when absolutely necessary.

6 The noiselevels within your systems are lower because thefans or air handling units are rarely at full IN CONTROLSS imple low voltage sensors complete with pre-plugged cable means that any control function iseasily achieved. You decide which conditions tomonitor and the system will operate at the optimum INTERFACEI ntegrated BMS features enable any central systemto control and monitor the fan or air handling unitvia 0-10V signal. This enables full speed controland heating or cooling enable if installed and voltfree status indication as OF MINDE cosmart has a 5 year further details contact SAVING ECOSMART CONTROLS THE MOST FLEXIBLE ENERGY SAVING VENTILATION CONTROL SYSTEM ON THE MARKET WITH FULL BMS SELV wired, plug-in enablers start and stop the fan, when activated from either start-up or trickle ventilation mode. These enablers includetime clocks, infra-red detectors, switch live contacts, humidistats, thermostats and BMS systems must include at least one enabler.

7 ( used, BMS control and time clocks take over all other enablers). Integrated speed control (inverter or electronic) is included with all Ecosmartcontrolled fans and air handlers. ES-ISC are EXTERNAL to some fans and need to be hard wired eg. SQF, Airmover. Once the fan is activated thesensor takes over. They will maintain comfort/design conditions by automatically adjusting fan speed up and down and power or flows throughelements or heating/cooling coils. The sensors include temperature, relative humidity, CO2or as determined by the dc signal to activate the system and modulatefan speed. Select/Deselect H&C. Note: this will over-ride any other devices (eg. ES-UCF) fitted (except inConstant Pressure fans ).ES-PIR2 (PASSIVE INFRA-RED)Detects movement and activates system. Incorporates a system status LED, overrun timer andtimer ENABLERS & DETECTORSECOSMART SPEED CONTROLLING SENSORSES-TEMP2 TEMPERATURE SENSORM odulate fan speed based on room temperatureIncorporates two system status LEDs (Green = OK, Red = Failure) and temperature setpoint level screen user control in white incorporatingtime clock facility.

8 This can control the function ofthe fan by manual setting or using a set of PLUG-IN SYSTEMES-RH2 RELATIVE HUMIDITY SENSORM odulate fan speed based on RH level. Incorporatestwo system status LEDs (Green = OK, Red = Failure) and RH set point level Touch screen user control in metal incorporatingtime clock facility. This can control the function ofthe fan by manual setting or using a set of timedprograms. ES-UCF MANUAL USER CONTROLM anual on and off system user/speed control. Incorporates two system status LEDs (Green = OK, Red = Failure).ES-HUMIDISTAT2 Activates the system when the RH level is above setpoint. Incorporates two system status LEDs (Green = OK, Red = Failure) and RH set point SEMI-AUTOMATIC USER CONTROLFan, heating & cooling selected by EXTERNAL volt freeswitch, speed selected by 0-10V the system when the temperature is aboveset point.

9 Incorporates two system status LEDs(Green = OK, Red = Failure) and temperature setpoint level JUNCTION BOXD esigned to be compatible with Ecosmart System thisunit is supplied with a pre-plugged 10 metre length ofcommunications cable and has 8 further fan failure occurs the AVI will flash a with pre-plugged 10m length of communication SENSORDuct mounted sensor to modulate fan speed basedon CO2levels. Connect to fan directly. Pre-wired with2m cable (not adjustable).ES-CO2RM / ES-CO2 RMPPS urface mounted room carbon dioxide (CO2) sensorswhich incorporate a temperature sensor. RM = SELV option, RMPP complete with SELV AC powers LIVE BY OTHERSAny mains voltage signal connected to the switchedlive terminal (S/L) in the unit. This affects the connected fan conditioning circuit for humidity, temperatureand CONTROLS & ANCILLARIESSTYLISH AND SIMPLE TO OPERATE USER CONTROL FACILITATES WITH MANUALOPERATION WHERE DESIRED8029 2085 8200 AIRE-VOLVE twin FANSTECHNICAL INFORMATIONPERFORMANCE - AIRE-VOLVE INTERNAL twin fans PERFORMANCE - AIRE-VOLVE INTERNAL twin fans AVT 1-9 ELECTRICAL & SOUNDC asingCode descriptionsAVT INTERNAL In-line twin AIRE-VOLVE range2.

10 twin Fan 3. Case size 1-9 AVT1 ||| 1 2 3 Fan Static Pressure (Pa)100200300400500600 Air volume flow rate (m /s)30 700604 VType DAir Density kg/m3 ISO 5801 2007 AMCA 30017898003254L 1. Unweighted induct inlet octave band Sound Power level - dB re 1pW 2. Unweighted induct outlet octave band Sound Power level - dB re 1pW 3. Casing radiated octave band Sound Power level - dB re 1pW Supply *Casing Radiated FreeCurve/ Duct (V/Freq FLC SC Input Power Fan Speed Frequency (Hz) Field dBA @ 3mCode conn.)


Related search queries