ALLROUNDER 375 V Technical data - w.plompen

ALLROUNDER 375 VA S GOLDEN EDITION V T dataVertical free-space systemClamping force: 500 kNInjection unit (acc. to EUROMAP): 100, 170, 290 2375 VMachine dimensionsVertikal-versionHorizontal versionCooling water connectionsElectrical connectionParting linemin. 100 / max. 200 Clamping surface, fixed mould platen1) Dimensions for injection unit 1002) Dimensions for injection unit 1703) Dimensions for injection unit 290 Clamping surface, fixed mould platenCooling water return line DN 25 Cooling water return line DN 25max.

ALLROUNDER 375 V A S GOLDEN EDITION V T www.arburg.com Technical data Vertical free-space system Clamping force: 500 kN Injection unit (acc. to EUROMAP): 100, 170, 290

Tags:

  System, Data, Technical, Technical data, Allrounder, Allrounder 375 v technical data, Allrounder 375 v

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ALLROUNDER 375 V Technical data - w.plompen

1 ALLROUNDER 375 VA S GOLDEN EDITION V T dataVertical free-space systemClamping force: 500 kNInjection unit (acc. to EUROMAP): 100, 170, 290 2375 VMachine dimensionsVertikal-versionHorizontal versionCooling water connectionsElectrical connectionParting linemin. 100 / max. 200 Clamping surface, fixed mould platen1) Dimensions for injection unit 1002) Dimensions for injection unit 1703) Dimensions for injection unit 290 Clamping surface, fixed mould platenCooling water return line DN 25 Cooling water return line DN 25max.

2 25 C min. D 4 1) 3490 2) 3735 3)20022002002125 1) 2310 2) 2555 3)10701638R 610R 390212033084028010503250 1) 3435 2) 3680 3)115800 3375 VTechnical dataMachine modelEUROMAP size indication1)Clamping unitClamping force max. kNClosing force max. kNOpening force max. kNOpening stroke max. mmMould height min. mmDaylight max. mmWeight of mov. mould half6) max. kgEjector force max. kNEjector stroke max. mmHydraulics, drive, generalDrive power of the hydraulic pump kWDry cycle time for opening stroke5) s-mmTotal connected load2) kWColour: plastic coated, structure light gray / mint green / canary yellowControl cabinetSafety standard according toSocket combination (1 single phase, 1 three-phase)Injection unitScrew diameter mmEffective screw length L/DScrew stroke max.

3 MmCalculated injection volume max. cm3 Shot weights max. g PSMaterial throughput4) max. kg/h PS max. kg/h PA pressure3) max. barInjection flow3) max. cm3/sBack pressure positive/negative max. barCircumferential screw speed max. m/minScrew torque max. NmNozzle contact force max. kNNozzle retraction stroke max. mmInstalled cylinder heating power / heating zones kWInstalled nozzle heating power kWMaterial hopper capacity lMachine dimensions and weights of the basic machineOil capacity lNet weight kgElectrical connection2) A1) 1st figure: clamping force (kN), 2nd figure: max.

4 Dosage volume (cm3) x max. injection pressure (kbar)2) Values refer to 400 V/50 Hz. The load is symmetrically distributed on three phases (observe phase loading when installing new equipment).3) A combination of max. injection pressure and max injection flow (max. injection capacity) can be mutually exclusive, depending on the equipment-related motor output. 4) Deviations are possible depending upon process settings and material type5) According to EUROMAP for basic ) Restriction only applies to vertical injection unitsThe shown specifications reflect the state at the time of printing.

5 In the interest of a continuous development of our products, we reserve the right to modify V500-1005004035250200-300450-55023030701 1---18 DIN EN 602041 x 16 A10020 / 25 / 3025 / 20 / 16,710031 / 49 / 7129 / 45 / 655,5 / 8 / 9,52,8 / 4 / 4,92500 / 2000 / 139064 / 100 / 146350 / 20028 / 35 / 42120 / 150 / 180501804,3 / 40,625160330063375 V500-1705004035250200-300450-55023030701 1---22 DIN EN 602041 x 16 A17025 / 30 / 3524 / 20 / 1712059 / 85 / 11554 / 77 / 10510 / 13,5 / 165 / 7 / 82500 / 2000 / 147066 / 96 / 132350 / 20035 / 42 / 49210 / 250 / 290502108,8 / 40,625160335063375 V500-2905004035250200-300450-55023030701 1---20 DIN EN 602041 x 16 A29030 / 35 / 4023,3 / 20 / 17,5150106 / 144 / 18897 / 132 / 17217 / 20,5 / 24,58,5 / 10,5 / 12,52500 / 2000 / 1530102 / 140 / 182350 / 20046 / 54 / 62320 / 380 / 430602405,8 / 40,6251603400634375 VEquipmentControl system and control cabinet SELOGICA direct (touchscreen user interface for direct data ac-cess)

6 Available in different language versions Language change Cycle sequence programming with symbols Cycle step display in sequence diagramj Cycle time diagram Swivelling monitor unit, central on the operator s side, with co-lour monitor Process graphics for injection speed, screw stroke and injection pressure Quality assurance program with fault evaluation and monitoring chart Optimisation and user help, follow-on functions at cycle end, for freely programmable parame-ter pages, selectable units Modular control cabinet design with self-recognition of plug in circuit board system Operating modes.

7 - Set up - Freely programmed test run - Reconfiguration - Automatic purging and dosingj Equipment for switch-over to holding pressure via injection pressure, material pressure with different pressure transducers, or via external switch signal data record management via Compact Flash Visual warning signal (warning lamp)j Visual / audible warning signal (flashing light / siren) Printer interface for hard copy, data record and quality protocolj Interfaces for: PC keyboard, plot-ter, robotic system in accordance with EUROMAP 67, host proces-sor, AQC, ALLROUNDER @web, colouring unit, LSR dosing sy-stem, INJESTER, container chan-ge, THERMOLIFT, hot runner con-trol unit and temperature control units for moulds and cylinder Socket combination 1 CEE, 1 Schuko 230 Vj Socket combination 1 CEE, 1 Schuko or 3 CEE, 3 Schuko 230 V with external supply linej 1 additional heating regulation circuit for the nozzlej Electric heating regulation circuits for moulds (adaptive) (3, 6, 9, 12)

8 ; mould heating fused at 10 Aj Fuses for mould heating 16 Aj 4 or 8 freely programmable inputs / outputsj Core pull programs in many ver-sions integrated in the SELOGICA control systemj Special processes such as injection coining and mould ventingj Monitoring: freely-programmable position monitoringMachine base and hydraulic system Free standing machine base on anti-vibration pads Guarding, adjustable on the par-ting line Space for peripheral devices within floor space The hydraulic system operates with an energy-saving variable displacement pump and a servo valve for pressure and speed regulation Monitoring of oil level.

9 Oil tempe-rature and oil filter contaminati-on Fine mesh oil filter in the return line Mechanical regulation of hydrau-lic oil temperaturej Electronic regulation of hydraulic oil temperature. Display and mo-nitoring via screen Hydraulic oil preheating program to reduce start-up time Manually adjustable, machine- related cooling water circuits with 2 free mould connectionsj 4 free cooling water circuits, manually adjustablej Programmable, machine and mould-related cooling water circuitsj 1 or 2 central shut-off valves for cooling water (supply and/or re-turn)Clamping unit Clamping unit with free-space system Centrally applied fully hydraulic clamping system .

10 Fixed mould platen positioned at bottom Mould height adjustment for achieving different mould installation heights Movement profiles for the mould clamping unit are programmable and regulated. They are serially driven using energy-saving one-circuit pump technology (Techno-logy stage 1) Closing and opening profiles are programmable in 2 stagesj Intermediate stop possible in closing and opening movements Regulated hydraulic mould pro-tection with monitoring of mould protection time. Follow-up func-tions: open or stop after 1 or 2 activations of mould protectionj Extended mould protection ( for spring moulds).