Example: marketing

Areamaster Generation 2 LED Luminaire Floodlight …

Areamaster Generation 2 LED LuminaireFloodlight for hazardous LocationsApplications Enclosed and gasketed fixtures suitable for use in: A wide range of industrial, chemical processing and other areas where flammable gases and vapors are present, for example Oil and Gas Refineries Petrochemical Plants Foundries Drilling Rigs Pulp and Paper Mills Food and Beverage Processing Facilities Loading Docks Power Plants Water and Wastewater Treatment Facilities Other areas where corrosive, wet, dirty and tough environments are a problem IP66/IP67, Type 4X, marine and wet locations locations requiring dependable, consistent lighting in extreme hot/cold temperature environments.

Areamaster™ Generation 2 LED Luminaire Floodlight for Hazardous Locations ATEX/IECEx Certifications and Compliances • Certification Type: Areamaster Gen …

Tags:

  Texas, Locations, Hazardous, Floodlight, Luminaire, Iecex, Led luminaire floodlight for hazardous locations atex

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Areamaster Generation 2 LED Luminaire Floodlight …

1 Areamaster Generation 2 LED LuminaireFloodlight for hazardous LocationsApplications Enclosed and gasketed fixtures suitable for use in: A wide range of industrial, chemical processing and other areas where flammable gases and vapors are present, for example Oil and Gas Refineries Petrochemical Plants Foundries Drilling Rigs Pulp and Paper Mills Food and Beverage Processing Facilities Loading Docks Power Plants Water and Wastewater Treatment Facilities Other areas where corrosive, wet, dirty and tough environments are a problem IP66/IP67, Type 4X, marine and wet locations locations requiring dependable, consistent lighting in extreme hot/cold temperature environments.

2 -40 C to +65 C (-40 F to +149 F) ambient temperature rangeFeatures Three lumen outputs provide up to 19,500 lumens. Nominal Lumens Wattage (W)Efficacy (lpw)HID EquivalentModel Number9,50070136175W-250 WAMLGL615,000110136250W-400 WAMLGL719,500150130400W-750 WAMLGL8 Nominal lumen value for 5000K, detailed lumen information provided in tables. Choice of optics for optimal light distribution in a variety of applications. Separate field wiring compartment with screw terminal block for easy and secure connection (can accept UL/CSA 26-10 AWG). Two 3/4 NPT entries provided. Yoke bracket is designed to accommodate traditional Areamaster brackets and slipfitters for easy retrofit.

3 Choice of color temperature (CCT); 5000K cool white or 3000K warm white. Rugged and compact housing with superior thermal design translates to long Luminaire life. Heavy duty, high temperature silicone rubber gaskets. Thermal shock and impact resistant clear or frosted glass lens. Standard 6KV surge protection. Captive fasteners secure one piece lens. Field replaceable LED driver and lens Improved safety cable design with multiple retention points, purchase separately Guard and visor available, purchase separately Slip-fitters and mounting brackets available for easy pole or wall mounting 10KV Surge ProtectionStandard Materials Housing and lens door: copperfree (4/10 of 1% max.)

4 Aluminum Gaskets: silicone rubber Yoke: zinc plated HR steel Bolts: stainless steel Close up plugs: (1) aluminum provided Guard and safety cable: stainless steel Visor: AluminumStandard Finishes Housing, lens cover, visor and yoke mount: architectural bronze polyesterRelated Products Round Tapered Steel Poles Hinged Steel Poled Square Tapered Steel Poles Square Steel Poles Floodlight Mounting BracketsNEC/CEC Certifications and Compliances UL Standards: UL844, Luminaires for Use in hazardous locations UL1598, Luminaires UL1598A, Luminaires for Installation on Marine Vessels UL 8750, LED Equipment for Use in Lighting Products CSA Standards: CSA No.

5 , Luminaires CSA No. 137, Luminaires for Use in hazardous locations cCSAus: 164460, Certificate Number: 70073611 NEC/CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Group IIC Class II, Division 1 and 2, Groups E, F, G Class III Zone 20 and 21 Group IIICNEC/CEC: Zone 22, Group IIIB Simultaneous Exposure Marine Outside Type (Salt Water) for USA ONLY Wet locations Type 3R, 4, 4X, IP66/67 ATEX/ iecex : Zone 2 and 22 IP66 II 3GD IK10 Ex ec llC T5 LED/FLooDLights: NEC/CEC, AtEx/ iecex ENCLosED AND gAskEtEDVisit our website at or contact us at (800) 621-1506. April 2018 261 Areamaster Generation 2 LED LuminaireFloodlight for hazardous LocationsATEX/ iecex Certifications and Compliances Certification Type: Areamaster Gen 2 Gas: Zone 2 Conforming to ATEX 2014/34/EU: II 3 G Type of Protection: Ex ec IIC Gc Temperature Class: T5 to T3 Dust: Zone 22 Conforming to ATEX 2014/34/EU: II 3 D Type of Protection: Ex tc IIIC Dc Surface Temperature: +85 C to +100 C (+185 F to +212 F) Ambient Temperature: -40 C up to +65 C (-40 F up to +268 F) EU Declaration of Conformity: 50317 ATEX Certificate: SIRA 17 ATEX3241 iecex Certificate: iecex SIR Index of Protection according EN/IEC 60529: IP66 Impact Resistance (shock).

6 IK10 Photobiological Safety, IEC 62778 and IEC 62471: RG0 Lumen Output Tables :Lumen Output for Clear Glass LensAMLGL6 AMLGL7 AMLGL8 NEMA 7x7 (Non Optic), 5000K CCT, CRI 709,90015,30019,900 NEMA 7x6, 3000K CCT, CRI 808,10011,90015,500 NEMA 7x6, 5000K CCT, CRI 709,00014,20018,400 Lumen Output for Frosted Glass LensAMLGL6 AMLGL7 AMLGL8 NEMA 7x7 (Non Optic), 5000K CCT8,00012,60016,300 3000K CCT (warm) is not available with NEMA 7x7 light pattern Frosted Glass is only available with NEMA 7x7 light pattern Use of fuse voids Marine rating. Fusing not available for NEC/CEC. All lumen values are typical (tolerance +/-10%). BH voltage available for NEC/CEC only. 10 KV Surge Protection available for NEC/CEC only.

7 Diffused polycarbonate available for NEC/CEC : Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Group IIC Class II, Division 1 and 2, Groups E, F, G Class III Zone 20 and 21 Group IIICNEC/CEC: Zone 22, Group IIIB Simultaneous Exposure Marine Outside Type (Salt Water) for USA ONLY Wet locations Type 3R, 4, 4X, IP66/67 ATEX/ iecex : Zone 2 and 22 IP66 II 3GD IK10 Ex ec llC T5 Order using catalog numbering guides below or select catalog number from tables on following : AMLG: Areamaster 2 LEDC olor Temp CCT:C - 5000KW - 3000K Beam Spread:6 - 7x7 (non-optic)7 - 7x6 Options:F - Fusing S - 10 KV Surge Protection M - M20 MetricLumen Level :L6 - 9KL7 - 15KL8 - 19 KDiffusion:G - Clear GlassF - Frosted Glass D - Diffused Polycarbonate Voltage:BU - 120-277 Vac 50/60 Hz, 170-300 VdcBH - 347-480 Vac 50/60 Hz DesignLights Consortium (for the following models) All models : NEC/CEC, AtEx/ iecex ENCLosED AND gAskEtEDVisit our website at or contact us at (800) 621-1506.

8 April 2018 262 Areamaster Generation 2 LED LuminaireFloodlight for hazardous LocationsElectrical Ratings Voltage SuffixVoltage (V)Input Power (Watts)Input Current (Amps)Power Factor (PF)Total Harmonic Distortion (THD)Model NumberBU120 >.9<20%AMLGL6277 >.9<20%480 >.9<20%AMLGL7277 >.9<20%480 >.9<20%AMLGL8277 >.9<20%480 Protection: Integral 6KV surge protection. Option for up to 10KV surge protection. (cCSAus only). All ratings are CategoryImageFrontal Projected Area(FPA) ft2 Drag Coefficient(DC)Effective Projected Area (EPA) = FPA*DC ft290 to Ground-Worst Case Mounting to Ground-Standard DirectionWind DirectionNEC/CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Group IIC Class II, Division 1 and 2, Groups E, F, G Class III Zone 20 and 21 Group IIICNEC/CEC: Zone 22, Group IIIB Simultaneous Exposure Marine Outside Type (Salt Water) for USA ONLY Wet locations Type 3R, 4, 4X, IP66/67 ATEX/ iecex : Zone 2 and 22 IP66 II 3GD IK10 Ex ec llC T5 LED/FLooDLights: NEC/CEC, AtEx/ iecex ENCLosED AND gAskEtEDVisit our website at or contact us at (800) 621-1506.

9 April 2018 263 Areamaster Generation 2 LED LuminaireFloodlight for hazardous locations T Numbers Represent the Maximum Internal Temperature or Maximum Surface Temperature NEC/CEC T #T1350325T2T2AT2BT2CT2DT3T3AT3BT3CT4T4AT 5T6 Temp. Range C ( F)351-450326-350301-325281-300261-280231 -260216-230201-215181-200166-180161-1651 36-160121-135101-12086-10085(664-842)(61 9-662)(574-617)(538-572)(502-536)(448-50 0)(421-446)(394-419)(358-392)(331-356)(3 22-329)(277-320)(250-275)(214-248)(187-2 12)(185)ATEX/ iecex T #T1T2T3T4T5T6 Temp. Range C ( F)301-450201-300136-200101-13586-10085(5 47-842)(394-572)(277-392)(214-275)(187-2 12)(185) T numbers represent the maximum internal temperature for Class I, Division 2 and Class I, Zone 2 locations designated by the NEC.

10 T numbers represent the maximum surface temperature under a dust blanket for Class II, Division 1 and 2 as designated by the Temperature CodesLampAmbientTemperature C ( F)Supply WireTemperature C ( F)GasDustClass I Division 2 and Class 2 Division IModel NumberLine VoltageClass I, Division 2 Groups A, B, C, DClass I, Zone 2 Group IICC lass II, Division 1 Groups E,F,GZone 20, Group IIIC120-277 Vac/ 170-300 Vdc; 347-480 Vac40 (104)90 (194)T5T5T6T6T4 AAMLGL655 (131)90 (194)T4AT4T6T6T4A65 (149)90 (194)T4AT4T6T6T4120-277 Vac/ 170-300 Vdc; 347-480 Vac40 (104)90 (194)T4AT4T6T6T4 AMLGL755 (131)90 (194)T3CT3T6T6T3C65 (149)90 (194)T3CT3T5T5T3C120-277 Vac/ 170-300 Vdc; 347-480 Vac40 (104)90 (194)T3CT3T6T6T3 CAMLGL855 (131)90 (194)T3BT3T5T5T3A65 (149)90 (194)T3AT3T5T5T3 AATEX/ iecex Temperature CodesGasDustModel NumberT RatingSurface TemperatureTa= +40 C (+104 F)Ta= +55 C (+131 F)Ta= +65 C (+149 F)Ta= +40 C (+104 F)Ta= +55 C (+131 F)Ta= +65 C (+149 F)T5T4T4T85 CT85 CT85 CAMLGL6T4T3T3T85 CT85 CT100 CAMLGL7T3T3T3T85 CT100 CT100 CAMLGL8 NEC/CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Group IIC Class II, Division 1 and 2, Groups E, F, G Class III Zone 20 and 21 Group IIICNEC/CEC: Zone 22, Group IIIB Simultaneous Exposure Marine Outside Type (Salt Water) for USA ONLY Wet locations Type 3R, 4, 4X, IP66/67 ATEX/ iecex .