C-mac Programmable converter PCV10 - Industrial …

C-mac . Programmable converter PCV10 . AC/DC current inputs from 15 A to 10 A. AC/DC voltage inputs from 10 mV to 1500 V. Frequency monitoring up to 5 kHz Analogue or pulse outputs Galvanic separation, supply - input - output DC supply or AC supply voltages up to 400 VAC. Made in accordance with the and EMC regulations PCV10 is a multirange converter / isolation amplifier All parameters in the converter are Programmable within the with current, voltage and pulse inputs and current, volt- specified limitations (min. and max. input and output levels), age, pulse or relay outputs.

1-2 1 56782 3 4 Supply Relay 1 Relay 2 C-mac 9 10111213 1516 Programmable converter PCV10 connections: Supply voltage. terminal 15 and 16 Inputs. 1

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of C-mac Programmable converter PCV10 - Industrial …

1 C-mac . Programmable converter PCV10 . AC/DC current inputs from 15 A to 10 A. AC/DC voltage inputs from 10 mV to 1500 V. Frequency monitoring up to 5 kHz Analogue or pulse outputs Galvanic separation, supply - input - output DC supply or AC supply voltages up to 400 VAC. Made in accordance with the and EMC regulations PCV10 is a multirange converter / isolation amplifier All parameters in the converter are Programmable within the with current, voltage and pulse inputs and current, volt- specified limitations (min. and max. input and output levels), age, pulse or relay outputs.

2 Giving the following possibilities: The unit is supplied with 3 current and 3 voltage input mA Output connections, which makes it possible to program any in- 20. put range between 15 A and 10 A or 15 mV and Basic converter , (0 to 16. 1000 VAC/1500 VDC. With DC-inputs it is possible to defined input range and 12. monitor both positive and negative signals. standard output range, 0-20 mA, 4-20 mA or 8. With AC inputs the converter monitors the RMS value of the signal, which means the signals are converted 0-10 V). 4. Input without any errors, no matter which shape they have. 0.

3 0 20 40 60 80 100%. The unit can also be programmed with frequency input, mA Output where the same input connections are used. The fre- 20. quency of the input signal is then monitored instead of converter with input 16. the analogue level. and/or output offset, 12. You can select between 2 different output configura- 12 to 50 VDC input 8. tions: and 8 to 15 mA output. 4. Type A is supplied with analogue current output, pro- 0. Input grammable between 0 and 20 mA and analogue volt- 0 20 40 60 80 100%. age output, Programmable between -10 and +10 V. mA Output 20. Type B has the same outputs as type A, but in addition Bidirectional input 16.

4 It is also supplied with pulse output, Programmable to range (only DC inputs), a maximum frequency of 10 kHz. -50 to +300 mA. 12. The unit is supplied with 2 trimming potentiometers, 8. which can be used to fine-adjust the metering range, if 4. the unit is used with analogue outputs. In either case the 0. Input potentiometers can be disabled and fixed values se- -40 -20 0 20 40 60%. lected, if adjustment is not required. V Output 10. If you want, you can order the unit with specified meter- Bidirectional output 6. ing ranges, or you can program it yourself, by means of range (only voltage the C-mac programming software for PC and a small in- output), -10 to +10.

5 2. 0. terface to connect between the PC and the module. -2. V. -6. Input -10. 0 20 40 60 80 100%. mA Output Inverted function with 20. or without offset, 16. 150 to 20 VAC input 12. and 4 to 20 mA output. 8. 4. Input 0. 0 20 40 60 80 100%. 1-1 Comadan Produktion a/s PCV10 connections: Supply voltage. Outputs, type PCV10 -A and PCV10 -B. terminal 15 and 16 9: output common 1 2 3 4 5 6 7 8. Inputs. 10: current output 11: voltage output C-mac 1: input common 12: pulse output ( type PCV10 -B only) Supply 2: 10 AAC/DC Relay 1. 3: 207 mAAC/292 mADC Relay 2. 4: 5,8 mAAC/8,2 mADC Programmable converter 5: 0,8 VAC/1,1 VDC.

6 6: 27 VAC/39 VDC 9 10 11 12 13 15 16. 8: 1000 VAC/1500 VDC. Connection drawings: Supply voltage, AC Supply voltage, DC Pulse outputs type PCV10 -B only): 9 10 11 12 13 15 16 9 10 11 12 13 15 16 9 10 11 12 13 15 16. - GND. IN NPN output. + Eksternal load: Current inputs: Voltage inputs: max. 30 V / 30 mA. High, max. High, max. 10 A AC/DC. 1000 VAC / 1500 VDC. + + 9 10 11 12 13 15 16. - - IN. + PNP output. 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Eksternal load: max. 30 V / 30 mA. Medium, max. 207 mA AC Medium, max. 292 mA DC 27 VAC / 39 VDC. + +. - - 9 10 11 12 13 15 16. - 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 + Pulse output.

7 V = 10 V. Low, max. 5,8 mA AC Low, max. out R = 2 kW. 8,2 mA DC 0,8 VAC / 1,1 VDC out + +. - - 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8. Analog current output: Analog voltage output: Programmable ranges Programmable ranges between 0 and 20 mA between -10 and +10 V. 9 10 11 12 13 15 16 9 10 11 12 13 15 16. Com Com + +/- Comadan 1-2. Produktion a/s Mechanical dimensions: Materials: Housing base: CYCOLOY C2100, 1 2 3 4 5 6 7 8 grey C-mac Frontplate: CYCOLOY C2100, grey 70,0. Supply Terminal cover: CYCOLOY C2100, Programmable converter black Terminals: nickel plated brass 9 10 11 12 13 15 16.

8 Screws: nickel plated iron 45,0 117,0. Weight: 350 g Programming connections and adjustments: Programming connector CON. Potentiometers P1 and P2. Connects to the PC via C-mac interface cable. The interface unit is internally battery powered, PCV10 -A and PCV10 -B: C-mac which means it is not necessary to connect any P1 = Offset fine adjust +/- 5%. external supply voltage to the PCV unit during P2 = Span fine adjust +/- 5%. programming. Function selector switch DS. 1 OFF: Normal mode 1 ON: Programming mode 2 OFF: Disable P1 adjustment 2 ON : Enable P1 adjustment 3 OFF: Disable P2 adjustment 3 ON : Enable P2 adjustment PCV10 programming.

9 Please notice, that it is only possible to adjust on one of It is possible to program and reprogram the unit at any the potentiometers at a time, you cannot set both time, no matter if the supply voltage is connected or not. switch 2 and 3 ON simultaneously. If the program is modified while the unit is installed and Reset to the programmed settings. in operation, all input signal conversions are disabled If you have fine-adjusted the programmed ranges, and and the output will not update as long as DS 1 is ON. you want to reset to the original settings, you use the Programming of the unit is made by following the in- following procedure:Set switch 2 or 3 ON, depending structions in the C-mac programming unit on which of the ranges you want to for the starts with the modified program as soon as DS 1 is supply LED to switch 1 ON, and reset switched back to OFF position.

10 Switch 2 or 3 to OFF switch 1 OFF again. Fine adjustments with potentiometer 1 and 2. Now the selected range has been reset, and you can re- In order to avoid unwanted modifications of the pro- peat the procedure on the other range, if you want. grammed ranges and to ensure a good temperature sta- bility it is only possible to fine-adjust the programmed metering ranges if you use the following procedure: When you have a known and stable input signal, you set switch 2 or 3 ON, for P1 or P2 adjustment, respec- the switch has been activated for minimum 2 seconds, the supply LED extinguishes and the output signal changes to the value, which corresponds to the ac- tual position of the potentiometer.