Search results with tag "Gpib"
SPEC Power and Temperature Measurement Setup Guide
www.spec.org2.2.3.1 GPIB-USB Adapters PTDaemon has been tested with National Instruments’ NI488.2 GPIB-USB-HS adapter and NI-488.2 software, and the Agilent 82357A USB/GPIB adapter. If the software and drivers are installed correctly, PTDaemon can access GPIB devices through the “gpib-32.dll” interface for National
2600B System SourceMeter SMU Instruments
download.tek.comGPIB, RS-232, LAN/LXI, USB GPIB, LAN/LXI Functionality Visualize data in time mode, two terminal I-V mode and family of curves mode. Analyze collected data interactively with smart device’s built-in capabilities. Share data instantly via mobile networks/Wi-Fi Custom scripts with total flexibility, full featured debugger Intuitive, wizard ...
Agilent 240/280 Series AA User's Guide
www.agilent.comGPIB communications 38. Contents . Agilent 240/280 Series AA (including Zeeman) 5 . Installing the USB -GPIB converter 38 Connecting and configuring an Agilent AA spectrometer DUO system 39 Setting up for DUO operation and connecting the IEEE cab les 39
OPERATING GUIDE GPIB DC POWER SUPPLIES Agilent ...
www.frankshospitalworkshop.comOPERATING GUIDE GPIB DC POWER SUPPLIES Agilent Technologies Models 664xA, 665xA, 667xA, and 668xA AGILENT Model 6641A: 3217A-00111 and Above * AGILENT Model 6642A: 3204A-00111 and Above *
IPC-TM-650 High Speed/High Frequency Test …
www.ipc.org• 10 dB Attenuator HP8491B • Programmable Power Meter HP436A • Power Sensor HP8484A with 70 to 10 dBm range • IEEE 488 (GPIB) cables • Controlling computer with GPIB …
抗血小板抗体の検出とその臨床的意義
yuketsu.jstmct.or.jp2 a Kob GPIb Thr145 98.2 99.3 bKoa,Siba Met145 25.4 14.6 3 a Baka,Leka GPIIb Ile843 78.9 87.7 b Bakb Ser843 70.7 64.1 4 a Yukb,Pena GPIIIa Arg143 99.9 >99.9 b Yuka,Penb Gln143 1.7 <0.2 5 a Bra GPIa Glu505 99.9 99.2 bBrb Lys505 8.6 20.6 15 a Govb CD109 Ser703 76.5 81.0 b Gova Tyr703 75.6 60.0 ル・スーリエ(Bernard-Soulier ...
E8257D PSG Microwave Analog Signal Generator - Keysight
www.keysight.comFeb 16, 2021 · 3 . Time from GPIB trigger to frequency within 0.1 ppm of final frequency above 250 MHz or within 100 Hz below 250 MHz. CW switching speed to within 0.05% of final frequency is ≥ 5 ms (nom). 4 . Add 12 ms (typical) when switching from greater than 3.2 GHz to less than 3.2 GHz. Option HY2 switching speed is 30 ms (nom) for 250 kHz
DAQ970A/DAQ973A Data Acquisition System - Keysight
www.keysight.comJul 14, 2021 · USB or GPIB interfaces is ideal for easy set up and control for data logging applications in remote locations. It’s a data acquisition front end The DAQ970A/DAQ973A is an automated test system with excellent measurement performance—it’s got the accuracy, resolution, and speed you need.
GPIB Hardware Installation Guide and Specifications ...
www.ni.com6 | ni.com | GPIB Hardware Installation Guide and Specifications NI PCIe-GPIB, NI PCIe-GPIB+, PCI-GPIB, PCI-GPIB+, PCI-GPIB/LP, and PCI-8232 Caution Electrostatic discharge can damage several components on your GPIB board.
GPIB-USB CONTROLLER - Prologix
prologix.bizMay 14, 2013 · 232) device. D2XX driver allows direct access to the controller via a DLL interface. 3. Firmware Upgrade Prologix GPIB-USB controller firmware is field upgradeable. Latest firmware and upgrade installations are available at prologix.biz 4. Host Software A wide variety of host software may be used to communicate with Prologix GPIB-USB controller:
GPIB Analyzer User Manual - National Instruments
www.ni.comNI-488.2 TM GPIB Analyzer User Manual GPIB Analyzer User Manual February 2003 Edition Part Number 371221A-01
Gpib Programming Tutorial - Boston University
g2pc1.bu.eduThe NeoNil has an gpib interface which conforms to the IEEE488.2 standard. Plug in cards The G96 plug in cards can be ‘off the shelf’ developed by our group or can be bought from an plug in card vendor. Also, custom plug in cards can be developed on demand. These custom plug in cards come in two favours: • Prototype quality.
GPIB, USB and Instrument Control - Keysight
www.keysight.comAug 18, 2021 · USB USBTMC-USB488 LAN/Ethernet Standard LAN (with HiSLIP, LXI, VXI-11, SICL-LAN and sockets) (Windows only) PXI, AXIe, PXI, PXIe, and PCIe devices VXI: FireWire (Windows 7 and 10, 32/64-bit) Find us at www.keysight.com Page 4 Supported development environments and supported I/O software Windows .NET languages (VB.NET, ...
BGP · P ART 1 - PacketLife.net
packetlife.net7 External Prefer eBGP routes over iBGP eBGP 8 IGP Cost Consider IGP metric Lowest 9 eBGP Peering Favor more stable routes Oldest 10 Router ID Tie breaker Lowest Influencing Path Selection Weight neighbor 172.16.0.1 weight 200 MED default-metric 400 Local Preference bgp default local-preference 100 Route Map neighbor 172.16.0.1 route-map Foo ...
BGP · P ART 1 - PacketLife.net
packetlife.netpacketlife.net by Jeremy Stretch v2.1-r1 BGP · P ART 1 Type About BGP eBGP AD iBGP AD Path Vector 20 200 Standard Protocols Transport Authentication RFC 4271 IP …
Similar queries
Power and Temperature Measurement Setup Guide, GPIB, GUIDE GPIB, POWER SUPPLIES Agilent Technologies Models 664xA, DAQ970A/DAQ973A Data Acquisition System, GPIB Hardware Installation Guide and Specifications, GPIB-USB controller, Controller, Interface, Host, GPIB Analyzer User Manual, National Instruments, GPIB Analyzer User Manual GPIB Analyzer User Manual, Gpib Programming Tutorial, Standard, Custom, GPIB, USB and Instrument Control, USBTMC, BGP · P ART 1, IBGP, EBGP