Example: biology

CBB-Series Technical Data sheet - Imperial - Emerson

data sheetDate: January CBB-SeriesTechnical data sheet - ImperialData sheetCBB-SeriesSheet No.: CBPI RevBDate: February 2010 Copyright Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website or from your nearest Valve Automation Center. USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 Ratings (Pneumatic)All Published Torques are Guaranteed Minimum ModelSee Bettis DefinitionsOperating Pressure (PSIG)405060708090100120 Pressure Torque Output (lb-in)CBB 315 Start/End678848101711871356152616952034 Minimum40450560670780891010111213 CBB 420 Start/End1536192123052689307334573841460 9 Minimum8711089130715251743196121792614

Data sheet Date: January 2013 DOC.DSB.CBB.US www.Bettis.com Bettis CBB-Series Technical data sheet - Imperial

Tags:

  Series, Sheet, Data, Technical, Imperial, Data sheet, Cbb series technical data sheet imperial

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CBB-Series Technical Data sheet - Imperial - Emerson

1 data sheetDate: January CBB-SeriesTechnical data sheet - ImperialData sheetCBB-SeriesSheet No.: CBPI RevBDate: February 2010 Copyright Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website or from your nearest Valve Automation Center. USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 Ratings (Pneumatic)All Published Torques are Guaranteed Minimum ModelSee Bettis DefinitionsOperating Pressure (PSIG)405060708090100120 Pressure Torque Output (lb-in)

2 CBB 315 Start/End678848101711871356152616952034 Minimum40450560670780891010111213 CBB 420 Start/End1536192123052689307334573841460 9 Minimum8711089130715251743196121792614 CBB 520 Start/End2133266632003733 Minimum1302162819542279 CBB 525 Start/End2944368044165152588866247361883 3 Minimum17202150258030093439386942995159 CBB725 Start/End57577197863610075 11515 Minimum34344292515160096868 Double-Acting ActuatorsCBB-SeriesSpring-Return ActuatorsCBB-SeriesActuator ModelSpringTorque (lb-in)Operating Pressure (PSIG)405060708090100120150 Pressure Torque Output (lb-in)CBB315 ModelSpringTorque (lb-in)Pressure Torque Output (lb-in)405060708090100120150 Operating Pressure (PSIG) data sheetCBB-SeriesSheet No.

3 : CBPI RevBDate: February 2010 Torque Ratings (Pneumatic)All Published Torques are Guaranteed Minimum Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website or from your nearest Valve Automation Center. USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 ModelSpringTorque (lb-in)Operating Pressure (PSIG)405060708090100120150 Pressure Torque Output (lb-in)CBB415 ModelSpringTorque (lb-in)Pressure Torque Output (lb-in)405060708090100120150 Operating Pressure (PSIG)Spring-Return ActuatorsCBB- series (cont.)

4 data sheetCBB-SeriesSheet No.: CBPI RevBDate: February 2010 Torque Ratings (Pneumatic)All Published Torques are Guaranteed Minimum Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website or from your nearest Valve Automation Center. USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 ModelSpringTorque (lb-in)Operating Pressure (PSIG)405060708090100120150 Pressure Torque Output (lb-in)CBB525 ModelSpringTorque (lb-in)Pressure Torque Output (lb-in)405060708090100120150 Operating Pressure (PSIG)Spring-Return ActuatorsCBB- series (cont.)

5 data sheetCBB-SeriesSheet No.: CBPI RevBDate: February 2010 Notes: CBA-SRXXM mechanical handwheel overrides are available on these models. The override adds approximately 2 lbs. (.8 kg) to the weight of the standard CBA model. Maximum volume including cavity required for calculating consumption per stroke.* Maximum Operating Pressure (MOP) is the pressure required to produce the maximum rated torque of the actuator.** Maximum Allowable Working Pressure (MAWP) is the maximum static pressure that may be applied to a fully stroked actuator against the travel stops.

6 Standard installation produces clockwise rotation when the outboard side of piston is pressurized. Standard installation produces counterclockwise rotation when the inboard side of piston is pressurized. Note: Actuator may be installed opposite of that shown aboveInboardSideof PistonOutboardSideof data (Pneumatic)Copyright Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website or from your nearest Valve Automation Center.

7 USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600 Double-Acting ActuatorsCBB-SeriesSpring-Return ActuatorsCBB-SeriesActuator ModelVolumeMaximum Operating Pressure (MOP)*Maximum Allowable Working Pressure (MAWP)**Approximate Weight of Actuator OutboardInboard (Housing)Cu. InchesCubic CmCu. InchesCubic 315 24 420 53 520 83 525 105 725 208 ModelVolumeMaximum Operating Pressure (MOP)*Maximum Allowable Working Pressure (MAWP)**Approximate Weight of ActuatorCu.

8 InchesCubic CBB 315-SR40SR60SR80SR1005454545488588588588 5155152 CBB CBB CBB CBB CBB sheetCBB-SeriesNote: Not Certified dimensional drawings. Such drawings available on request. Contact factory with correct model designation and serial number. All dimensions are expressed in : September 2010 sheet No.: CBPI RevBCopyright Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website or from your nearest Valve Automation Center.

9 USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 (Pneumatic) ActuatorsCBBXXXA ctuator sheetCBB-SeriesNote: Not Certified dimensional drawings. Such drawings available on request. Contact factory with correct model designation and serial number. All dimensions are expressed in : September 2010 sheet No.: CBPI RevBDouble-Acting ActuatorsCBBXXX (cont.)Copyright Emerson Process Management. The information in this document is subject to change without notice.

10 Updated data sheets can be obtained from our website or from your nearest Valve Automation Center. USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 (Pneumatic) sheetCBB-SeriesNote: Not Certified dimensional drawings. Such drawings available on request. Contact factory with correct model designation and serial number. All dimensions are expressed in No.: CBPI Rev DSpring-Return ActuatorsCBB XXX-SRXDate: January 2013 Copyright Emerson Process Management. The information in this document is subject to change without notice.


Related search queries