Transcription of Circuit Breakers Return To MAIN INDEX Disconnect …
1 Circuit Breakers Return To MAIN INDEX Disconnect Switches, Molded case Switches Overview 8/2. Instantaneous Trip Circuit Breakers , NZMH 8/4. Motor Disconnect Switches, NZMH 8/5. Accessories 8/6. 80 A. Inverse time Circuit Breakers , NZM(H) 6(B) 8/12. Instantaneous Trip Circuit Breakers , NZM(H) 6(B)- OBI-CNA 8/13. Motor Disconnect Switches, NZM(H) 6(B) 8/14. 125 A Motor Disconnect Switches, N 8/15. Accessories 8/16. Inverse time Circuit Breakers , NZM(H) 8/22. Instantaneous Trip Circuit Breakers , NZM(H) 8/23. Motor Disconnect Switches, NZM(H) 8/24.
2 Disconnect Switches, Molded case Switches 250 A Motor Disconnect Switches, N 8/25. Accessories 8/26. Inverse time Circuit Breakers , NZM (A)(V) 8/32. Motor Disconnect Switches, N 8/33. Accessories 8/34. 1000 A. Circuit Breakers Overview NZM 8/40. Inverse time Circuit Breakers , NZM 7(A) (-M8) 8/44. Molded case Switches, NZM (-M8) 8/45. 150 A Accessories 8/46. Overview NZM 8/54. 8. Inverse time Circuit Breakers , NZM (N)(S)(H)-NA 8/58. Instantaneous Trip Circuit Breakers , NZM 8/60. 600 A Molded case Switches, NZM 8/61. Components for NZM Circuit Breakers 8/62.
3 Accessories 8/64. Trip Curves 8/72. Technical Data 8/77. Dimensions 8/84. 1. For Immediate Delivery call at (866) 595-9616 8/1. Circuit Breakers Type (C)NA UL / CSA / CE / IEC/EN 60 947. Ratings Overview 1 2 3 4 5. Inverse Time Circuit Breakers Frame Rating UL/ CSA Interrupting Ratings kA RMS SYM Amps 240 VAC 480 VAC 600 VAC. Thermal-Magnetic Trip UL 489/CSA No. ; IEC/EN 60 947-2. NZM 15 - 125 25 25 14. NZMH 15 - 125 100 65 25. Fuseless Current Limiting NZM ) 25 - 150 65 25 . Disconnect Switches, Molded case Switches NZM 70 - 250 30 25 18.
4 NZMH 70 - 250 200 85 42. Fuseless Current Limiting Circuit Breakers Solid State Trip UL 489/CSA No. ; IEC/EN 60 947-2. NZM 10(A) 200 - 600 65 42 35. NZM 10(A) 200 - 600 100 65 42. 8 NZM 10(A) Fuseless Current Limiting 200 - 600 200 100 50. With trip delay feature for selectivity in networks NZM 10V(A) 200 - 600 65 42 35. NZM 10V(A) 200 - 600 100 65 42. NZM 12(A) ) 300 - 1000 65 65 50. With trip delay feature for selectivity in networks NZM ) 300 - 1000 65 65 50. 1) Type NZM currently UL/CSA only. IEC 60 947-2 Conformity in preparation.
5 2) Type NZM UL/CSA only. All Inverse time Circuit Breakers are UL Listed and CSA Certified, in compliance with IEC/EN 60 947-2 ( Circuit Breakers ) and CE Marked. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings. 8/2 For Immediate Delivery call at (866) 595-9616. UL / CSA / CE / IEC/EN 60 947 Circuit Breakers / Disconnect /Molded case Switches Ratings Overview 1 2 3 4 5. Instantaneous Trip Circuit Breakers Frame Rating UL/ CSA Interrupting Ratings kA RMS SYM Amps 240 VAC 480 VAC 600 VAC.
6 Instantaneous Trip Type Circuit Breakers UL 489/CSA No. NZMH - 18 UL Recognized and CSA Certified Instantaneous Trip Circuit Breakers no longer carry interrupting ratings as NZMH CDN - 18 stand-alone devices. Per the intent of NEC Article 430-52, an instantaneous NZM - 125 trip Circuit breaker shall be used only if part of a listed combination motor controller. Short Circuit ratings are, NZMH 33 - 125 therefore, established and valid only for the listed combination motor controller assembly and associated NZM 63 - 250 housing or enclosure.
7 Consult Section 3 of this catalog for Combination Motor NZMH 63 - 250 Controller short Circuit ratings as standard starters featuring Type NZM Instantaneous Trip Circuit Breakers . Disconnect Switches, Molded case Switches NZM 400 - 600 Consult Moeller Electric for Combination Motor Control- ler high fault short Circuit ratings as Motor Control Center NZM 400 - 600 unit starters featuring Type NZM Instantaneous Trip Circuit Breakers . Motor Disconnect Switches UL / CSA Short Circuit Ratings UL 508/CSA Nr. 14, IEC/EN 60 947-2, CE.
8 HP rated, with adjustable thermal and magnetic trips 1). NZMH 4 - 80 100 25 25. Circuit Breakers NZM 15 - 125 25 25 14. NZMH 15 - 125 100 65 25. NZM 63 - 250 30 25 18. NZMH 63 - 250 200 85 42. Motor Disconnect Switches UL 508/CSA Nr. 14, IEC/EN 60 947-3, CE. HP rated, without trip elements 8. 150 10 10 10. 250 10 10 10. 2) 1200 42 42 42. Molded case Switches UL 1087, CSA Nr. , IEC/EN 60 947-3, CE. Without trip elements NZM (-M8) 200 25 25 18. NZM 600 25 25 25. 1) NZMH in the range 4 - 16 Amps, UL/CSA only. 2) , UL/CSA only.
9 Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings. For Immediate Delivery call at (866) 595-9616 8/3. Molded case Circuit Breakers - Instantaneous Trip UL/CSA. Type NZMH 1 2 3 4 5. Frame Continuous Adjustable Type Price Rating Current Magnetic Trip Rating Range Amps Amps $. Instantaneous Trip Circuit Breakers See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Up to 480 V AC, UL/CSA.
10 NZMH 4-2, 1-12-OBI-CNA. NZMH 4-3, 7-20-OBI-CNA. 18 ..32 NZMH 4-6, 6-32-OBI-CNA. 10 28 ..50 NZMH 4-10, 50-OBI-CNA. 12 42 ..80 NZMH 4-12, 80-OBI-CNA. 15 64 ..120 NZMH 4-15, 120-OBI-CNA. 18 200 NZMH 4-18, 200-OBI-CNA. NZMH Disconnect Switches, Molded case Switches (18 Amps). Instantaneous Trip Circuit Breakers Up to 600Y/347 V AC, CSA Certified only NZMH 4-2, 1-12-OBI-FORM CDN. NZMH 4-3, 7-20-OBI-FORM CDN. 18 ..32 NZMH 4-6, 6-32-OBI-FORM CDN. 10 28 ..50 NZMH 4-10, 50-OBI-FORM CDN. 12 42 ..80 NZMH 4-12, 80-OBI-FORM CDN. Circuit Breakers 15 64.