Transcription of Cisco UCS C240 M5 SFF Rack Server Spec Sheet
1 Cisco SYSTEMSPUBLICATION HISTORY170 WEST TASMAN JOSE, CA, 95134 REV 16, SheetCisco UCS C240 M5 Rack Server (Small Form Factor Disk Drive Model) Cisco UCS C240 M5 Rack Server (Small Form Factor Disk Drive Model)2 CONTENTSOVERVIEW .. 3 DETAILED VIEWS .. 4 BASE Server STANDARD CAPABILITIES and FEATURES .. 8 CONFIGURING the Server .. 12 STEP1 VERIFY Server SKU .. 13 STEP2 SELECT RISER CARDS (REQUIRED) .. 14 STEP3 SELECT CPU(s) .. 15 STEP4 SELECT MEMORY .. 21 STEP5 SELECT RAID CONTROLLERS .. 28 STEP6 SELECT DRIVES .. 33 STEP7 SELECT PCIe OPTION CARD(s).
2 41 STEP8 ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES .. 45 STEP9 ORDER GPU CARDS (OPTIONAL) .. 50 STEP10 ORDER POWER SUPPLY .. 53 STEP11 SELECT INPUT POWER CORD(s) .. 54 STEP12 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . 58 STEP13 SELECT MANAGEMENT CONFIGURATION (OPTIONAL) .. 59 STEP14 SELECT Server BOOT MODE (OPTIONAL) .. 60 STEP15 SELECT LOCKING SECURITY BEZEL (OPTIONAL) .. 61 STEP16 ORDER SECURITY DEVICES (OPTIONAL) .. 62 STEP17 ORDER OPTICAL DRIVE (OPTIONAL) .. 63 STEP18 ORDER Cisco SD CARD MODULE (OPTIONAL).
3 64 STEP19 ORDER SATA SSD (OPTIONAL) .. 65 STEP20 ORDER INTERNAL MICRO-SD CARD MODULE (OPTIONAL) .. 67 STEP21 ORDER OPTIONAL USB DRIVE .. 68 STEP22 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE .. 69 STEP23 SELECT OPERATING SYSTEM MEDIA KIT .. 73 STEP24 SELECT SERVICE and SUPPORT LEVEL .. 74 SUPPLEMENTAL MATERIAL .. 82 SPARE PARTS .. 94 UPGRADING or REPLACING CPUs .. 109 UPGRADING or REPLACING MEMORY .. 110 DISCONTINUED EOL PRODUCTS .. 112 NEBS Compliance .. 120 TECHNICAL SPECIFICATIONS .. 121 Cisco UCS C240 M5 Rack Server (Small Form Factor Disk Drive Model)OVERVIEW3 OVERVIEWThe UCS C240 M5 SFF Server extends the capabilities of Cisco s Unified Computing System portfolio in a 2U form factor with the addition of the 2nd Generation Intel Xeon Scalable Processors, 2933-MHz DDR4 memory, and the new 512GB Intel Optane Persistent Memory Modules (PMem).
4 With this combination of features, up to 9 TB of memory is possible (using 12 x 256 GB DDR4 DIMMs and 12 x 512 GB PMem), up to 6 PCI Express (PCIe) slots, and up to 26 internal SFF drives. The C240 M5 SFF Server also includes one dedicated internal slot for a 12G SAS storage controller C240 M5 Server includes a dedicated internal modular LAN on motherboard (mLOM) connector for installation of a Cisco Virtual Interface Card (VIC) or third-party network interface card (NIC), without consuming a PCI slot, in addition to 2 x 10 Gbase-T Intel x550 embedded (on the motherboard)
5 LOM Cisco UCS C240 M5 Server can be used standalone, or as part of the Cisco Unified Computing System, which unifies computing, networking, management, virtualization, and storage access into a single integrated architecture enabling end-to-end Server visibility, management, and control in both bare metal and virtualized 1 Cisco UCS C240 M5 SFF Rack Server (26-drive version)Front ViewRear ViewCisco UCS C240 M5 Rack Server (Small Form Factor Disk Drive Model)4 DETAILED VIEWSDETAILED VIEWSC hassis Front ViewFigure 2 shows the 26-drive Cisco UCS C240 M5 SFF Rack 2 Chassis Front View (24 front drives, 2 rear drives version)1 UCSC-C240-M5SX: Drive bays 1 24 support SAS/SATA drives.
6 UCSC-C240-M5SN: Drive bays 9 24 support SAS/SATA status LED2 UCSC-C240-M5SX: Drive bays 1 and 2 support NVMe PCIe SSDs. All bays support SAS/SATA drives UCSC-C240-M5SN: Drive bays 1 8 support only NVMe PCIe SSDs. Bays 9 24 support only SAS/SATA drives8 Power supply status LED3 Power button/Power status LED9 Network link activity LED4 Unit Identification button/LED10 Pull-out asset tag5 System status LED11 KVM connector(used with KVM cable that provides two USB , one VGA, and one serial connector)6 Fan status LEDSlot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9 Slot 10 Slot 11 Slot 12 Slot 13 Slot 14 Slot 15 Slot 16 Slot 17 Slot 18 Slot 19 Slot 20 Slot 21 Slot 22 Slot 23 Slot 243059893456789121011 Cisco UCS C240 M5 Rack Server (Small Form Factor Disk Drive Model)DETAILED VIEWS5 Figure 3 shows the 10-drive Cisco UCS C240 M5 SFF Rack 3 Chassis Front View (8 front drives, 2 rear drives version)1 UCSC-C240-M5S: Drive bays 1 8 support SAS/SATA status LED2 UCSC-C240-M5S.
7 Drive bays 1 and 2 support NVMe PCIe supply status LED3 Power button/Power status LED9 Network link activity LED4 Unit Identification button/LED10 Optional media drive (DVD)5 System status LED11 Pull-out asset tag6 Fan status LED12 KVM connector(used with KVM cable that provides two USB , one VGA, and one serial connector)Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8305990345678912111210 Cisco UCS C240 M5 Rack Server (Small Form Factor Disk Drive Model)6 DETAILED VIEWSC hassis Rear ViewFigure 4 shows the external features of the rear panel (identical for all Server versions).
8 Figure 4 Chassis Rear View1 PCIe riser 1 (slots 1, 2, 3)Two options: Riser 1 option slot 1 (x8, CPU1 controlled) slot 2 (x16, CPU1 controlled) slot 3 (x8, CPU2 controlled) Riser 1B option slot 1 (x8, CPU1 controlled) slot 2 (x8, CPU1 controlled) slot 3 (x8, CPU1 controlled)See Riser Card Configuration and Options, page 88 for ports (two)2 PCIe riser 2 (slots 4, 5, 6)Four options: Riser 2A option slot 4 (x16, CPU2 controlled) slot 5 (x16, CPU2 controlled) slot 6 (x8, CPU2 controlled)8 Dual 1/10 GB Ethernet ports (LAN1, LAN2)LAN1 is left connector,LAN2 is right connector305992 PCIe 03 PCIe 02 PCIe 01mLOMPCIe 06 PSU 01 PSU 02 PCIe 05 PCIe 04 Rear Bay 01 Rear Bay 02167910111285243 Cisco UCS C240 M5 Rack Server (Small Form Factor Disk Drive Model)DETAILED VIEWS72 (cont.)
9 Riser 2B option slot 4 (x8, CPU2 controlled) slot 5 (x16, CPU2 controlled) slot 6 (x8, CPU2 controlled) One x8 NVMe connector (for two rear NVMe drives) from slot 4 Riser 2C option slot 4 (x8, CPU2 controlled) slot 5 (x8, CPU2 controlled) slot 6 (x8, CPU2 controlled) Two x8 NVMe connectors (for two front NVMe and two rear NVMe drives) from slots 4 and 5 Riser 2D option (always ships with UCSC- C240-M5SN) slot 4 (x16, CPU2 controlled) slot 5 (x8, CPU2 controlled) slot 6 (x8, CPU2 controlled) One NVMe connector (for two rear drives) from slot 6 See Riser Card Configuration and Options, page 88 for drive bays: Server PID UCSC-C240-M5SN supports up to two NVMe PCIe SSDs (only), controlled by Riser 2.
10 All other C240 M5 PIDs support up to two rear drives: When using a hardware RAID controller card in the Server , SAS/SATA drives or NVMe SSDs are supported in the rear bays. When using software RAID in the Server , only NVMe SSDs are supported in the rear bays, controlled by Riser video port (DB-15 connector)4 Power supplies (two, redundant as 1+1)101-Gb Ethernet dedicated management port5 Screw holes for dual-hole grounding lug11 Serial port (RJ-45 connector)6 Modular LAN-on-motherboard (mLOM) card slot (x16)12 Rear Unit Identification button/LEDC isco UCS C240 M5 Rack Server (Small Form Factor Disk Drive Model)