Commercial GasWater HeaterFor complete warranty information consult the written warranty of American Water heaters found or call (800) 999-9515 | Copyright by American Water heaters November 2016. All Rights 1 of 4 NCGSS00216 CONDENSING DESIGN Operates at up to 96% thermal efficiency which saves money on operating costs compared to a standard 80% efficient gas Water Heater . Helical internal heat exchanger keeps hot combustion gases in the tank longer to extract more heat into the STEEL CONSTRUCTION Tank and helical heat exchanger are constructed from 444 stainless steel for excellent corrosion resistance without the need for an QUIET OPERATION Ultra quiet blower and burner to minimize DIRECT VENT DESIGN Direct vent using PVC, CPVC or Polypropylene (solid core only) through a sidewall or roof.

For technical information call (00) 999-9515. American Water Heaters reserves the right to mae product changes or improvements ithout prior notice.

Tags:

  Commercial, Water, Heaters, Water heaters, Commercial gas water heater

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Commercial Gas Water Heater - American Water …

1 Commercial GasWater HeaterFor complete warranty information consult the written warranty of American Water heaters found or call (800) 999-9515 | Copyright by American Water heaters November 2016. All Rights 1 of 4 NCGSS00216 CONDENSING DESIGN Operates at up to 96% thermal efficiency which saves money on operating costs compared to a standard 80% efficient gas Water Heater . Helical internal heat exchanger keeps hot combustion gases in the tank longer to extract more heat into the STEEL CONSTRUCTION Tank and helical heat exchanger are constructed from 444 stainless steel for excellent corrosion resistance without the need for an QUIET OPERATION Ultra quiet blower and burner to minimize DIRECT VENT DESIGN Direct vent using PVC, CPVC or Polypropylene (solid core only) through a sidewall or roof.

2 Optional concentric vent kit. 2 pipe vents up to 52 equivalent feet (100-150k BTU/hr inputs) 3 pipe vents up to 130 equivalent feetADVANCED ELECTRONIC CONTROL Large touchscreen display Precise temperature control Advanced Water Heater status and diagnostics FULLY SERVICEABLE FROM THE FRONT Two front access panels expose all serviceable components. Modular components are all easily NOX MODULATING GAS BURNER Enhanced Ultra-low NOx burner complies with SCAQMD Rule and other Air Quality Management Districts with similar requirements for NOx emissions of less than 14 ng/j. Modulating burner maintains high efficiency operation at lower input HOT AND COLD RECIRCULATING TAPS Polaris can be easily installed with a recirculation system or as part of a combined domestic & space heating IN NATURAL GAS OR PROPANECSA CERTIFIED AND ASME RATED T&P RELIEF VALVESTANDARDS AND CERTIFICATIONS Design-certified by CSA International according to ANSI CSA Standards.

3 Meets UBC, CEC, and ICC National Codes. Meets the thermal efficiency and standby loss requirements of the U. S. Department of Energy and current edition of ASHRAE/IES LIMITED TANK AND 1-YEAR PARTS WARRANTY For complete information, consult written warranty or go to HIGH EFFICIENCYFor technical information call (800) 999-9515. American Water heaters reserves the right to make product changes or improvements without prior GasWater HeaterPage 1 of 4 NCGSS00216 American Water heaters | 5500 Princeton Road (FEDEX, UPS), Johnson City, TN 37601-2030 | 1597 (Mailing), Johnson City, TN 37605-1597 Copyright by American Water heaters November 2016. All Rights NumberGallon CapacityBTU/h Input Gallon Per HourThermal EfficiencyRecovery @ 90 Rise Gallon Per Hour Dimensions in InchesVent Connection1 Water Connections T&PGas Supply*Approx.

4 Shipping Weight (lbs)ABCDE FPGC3 34 130 2NV34130,00096%16548-1/2222 or 315-3/440-1/2416-3/8150 PGC3 34 150 2NV34150,00094%19048-1/2222 or 315-3/440-1/2416-3/8150 PGC3 50 130 2NV50130,00095%16562-3/8222 or 315-3/454-1/2556-3/8176 PGC3 50 150 2NV50150,00095%19063-3/4222 or 315-3/455-3/456-1/46-3/8180 PGC3 50 175 3NV50175,00096%22263-3/422315-3/455-3/45 6-1/46-3/8180 PGC3 50 199 3NV50199,00096%25363-3/422315-3/455-3/45 6-1/46-3/8180*For propane models change N to P in the model number (example: PCG3 50 199 3PV)Models certified for sea level to 7,700 ft. TapsAir InletAdditionalSide TapsAir InletTop Outlet: 1 NPTSide Inlet: 1 NPTSide Taps: 1 NPTC ondensate Drain Outlet: 1/2 NPTSUGGESTED SPECIFICATION(Natural or Propane) gas Water Heater (s) shall be American Polaris model with storage capacity _____ and input rating of _____ BTUs per hour.

5 Water Heater (s) shall have: 1: Tank constructed of 444 stainless steel with submerged combustion chamber. 2: Advanced electronic control w/ LCD display and actual diagnostics. 3: A 3-year limited warranty against tank leaks. Water Heater (s) shall meet the thermal efficiency and standby loss requirements of the Department of Energy and current edition of ASHRAE/IES and be design certified by CSA International according to ANSI standards governing storage tank Water heaters .