Connectivity solutions from one supplierEthernet-connectivity87654321876 54321 ethernet -infrastructure - solutions from one supplierThe requirements for high speed manufacturing are becoming more need for integrating the office with the shopfloor has seen modern automationrequiring PC control and ethernet crucial factor in the performance of ethernet based networks is the correct selectionof cables and terminations that will ensure correct functionality of the system in harshindustrial offers a complete range of cables, assemblies and industrial Switches/Hubsallowing customers to acquire all their Connectivity requirements from one has many years of experience in the design and configuration of industrial net-works and components and this knowledge allows us to realise customers specific solutions when areaControl cabinetMedia converterFibre/TxPatch cableRJ45/RJ45 StraightDIO-SWITCHL TZE ethernet BUSL TZE SUPERFLEX ethernet BUSC-trackMachineEthernetmeasuringdevice DIOSWITCHMINIT erminal boxTerminal boxEthernet IODIOHUBL TZE ethernet BUSE thernet sensorDIOSWITCHIP67IP20 areaIP67 areaMaximum length forMediumCableMaximum length10 Mbit/s-Ethernet10 BASE-TTwisted Pair100 m100 Mbit/s-F

8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 Ethernet-infrastructure - solutions from one supplier The requirements for high speed manufacturing are becoming more complex. The need for integrating the office with the shopfloor has seen modern automation

Tags:

  Form, Solutions, Supplier, Ethernet, Solutions from one supplier

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Connectivity solutions from one supplier - …

1 Connectivity solutions from one supplierEthernet-connectivity87654321876 54321 ethernet -infrastructure - solutions from one supplierThe requirements for high speed manufacturing are becoming more need for integrating the office with the shopfloor has seen modern automationrequiring PC control and ethernet crucial factor in the performance of ethernet based networks is the correct selectionof cables and terminations that will ensure correct functionality of the system in harshindustrial offers a complete range of cables, assemblies and industrial Switches/Hubsallowing customers to acquire all their Connectivity requirements from one has many years of experience in the design and configuration of industrial net-works and components and this knowledge allows us to realise customers specific solutions when areaControl cabinetMedia converterFibre/TxPatch cableRJ45/RJ45 StraightDIO-SWITCHL TZE ethernet BUSL TZE SUPERFLEX ethernet BUSC-trackMachineEthernetmeasuringdevice DIOSWITCHMINIT erminal boxTerminal boxEthernet IODIOHUBL TZE ethernet BUSE thernet sensorDIOSWITCHIP67IP20 areaIP67 areaMaximum length forMediumCableMaximum length10 Mbit/s-Ethernet10 BASE-TTwisted Pair100 m100 Mbit/s-Fast Ethernet100 BASE-TXTwisted Pair100 mApplication classes forClassFrequencyApplicationCablesymmetr ic copper cablesKl.

2 Dup to 100/125 MHz Data connections: Telephone, ISDN, Token RingCAT5(100 ) ethernet (Gigabit ethernet ), FDDI, TPDDI, 100 VG Anylan(CAT5a)Kl. Eup to 250 MHzData connections: Telephone, ISDN, Token RingCAT6 ethernet (Gigabit ethernet ), FDDI, TPDDI, 100 VG Anylan1:1-cableEthernet connection cablesTo connect two ethernet devices, two types of cables are necessary. The 1:1-cable and the cross over ,DIOSWITCH IP67 andDIOSWITCH MINI detect the RX/TX conductors themselves(autocrossing). Thereforeboth types of cables (1:1 or cross over) canbe RJ45 pinoutsThe ANSI/EIA/TIA-568-1991 standard defines two pinouts: EIA/TIA T568A and EIA/TIA T568B. The more commonstandard is the T568B also called AT specification, previously called 258A. T568B is identical to T568A except thatpairs 2 (orange) and 3 (green) are swapped.

3 For 10 BASE-TX and 100 BASE-TX a 4 conductor cable is required for1000 BASE-TX 8 conductors are necessary. Cross over cableA 1:1 cable is necessary if a computer has to be connected to a hub or a cross over cable is necessary if two computers have to be connected directly (peer topeer), without using a Hubor a Switch or if two Hub sor Switches have to be connected for ColourFunctionFunctionConductor10 BASE-T, 1000 BAS-TX100 BASE-TX1 WHT/ORG Rx+BI_DB+2 ORGRx-BI_DB-3 WHT/GRN Tx+BI_DA+4 BLUBI_DD+5 WHT/BLUBI_DD-6 GRNTx-BI_DA-7 WHT/BRNBI_DC+8 BRNBI_DC-Pair 3 Pair 1 Pair 4 Pair 2 MDI Pin Colour FunctionFunction(EIA/TIA T568A)Conductor10 BASE-T, 1000 BAS-TX100 BASE-TX1 WHT/GRN Tx+BI_DA+2 GRNTx-BI_DA-3 WHT/ORG Rx+BI_DB+4 BLUBI_DC+5 WHT/BLUBI_DC-6 ORGRx-BI_DB-7 WHT/BRNBI_DD+8 BRNBI_DD-Pair 2 Pair 4 Pair 1 Pair 3 Pair 3 Pair 4 Pair 2 Pair 1 ethernet M12 PinColour FunctionConductor10 BASE-T,100 BASE-TX1 BLU/YELTx+2 YEL/WHTRx+3 WHT/ORGTx-4 ORG/BLURx-Pair 1 Pair 2RJ45 connector RJ45 connectorM12M12M12RJ45, MDIRJ45 connector RJ45 connectorMDI Pin Colour FunctionFunction(EIA/TIA T568B)Conductor10 BASE-T, 1000 BAS-TX100 BASE-TX1 WHT/ORG Tx+BI_DA+2 ORGTx-BI_DA-3 WHT/GRN Rx+BI_DB+4 BLUBI_DC+5 WHT/BLUBI_DC-6 GRNRx-BI_DB-7 WHT/BRNBI_DD+8 BRNBI_DD- CAT5/6 ethernet TypePart for industrial L TZE ethernet BUS (C) PUR (2x2x0,22)

4 104243environment* violetL TZE ethernet BUS (C) PUR (4x2x0,22)104244outer jacket RAL 4001L TZE ethernet BUS (C) PUR (2x2x0,22) UL104247 DESINAL TZE ethernet BUS (C) PUR (4x2x0,22) UL104248IP20 infrastructure TypePart DIOSWITCH 8 ports 10/100base-T, DIN rail mounted745568 DIOSWITCH MINI 6TX6 Ports, 2 screw terminal connections, DIN rail mounted745570 DIOSWITCH MINI 8TX 8 Ports, DIN rail mounted745571IP67 infrastructure TypePart DIOSWITCH IP67 8 ports 10/100base-T, DIN rail mounted745569 Superflex BUS CAT5 TypePart cables for L TZE SUPERFLEX ethernet BUS (C) PUR (2x2x0,22)104241C-track applications*L TZE SUPERFLEX ethernet BUS (C) PUR (4x2x0,22)104242violet outer jacket L TZE SUPERFLEX ethernet BUS (C) PUR (2x2x0,22) UL104245 RAL 4001 DESINAL TZE SUPERFLEX ethernet BUS (C) PUR (4x2x0,22) UL104246 CAT5 ProfiNet TypePart cables for L TZE ELECTRONIC ethernet BUS (C) Y(2x2x0,65) StC104301industrial environment*L TZE ELECTRONIC ethernet BUS (C) HM FC (2x2x0,65) StC104302green outer jacket L TZE ELECTRONIC ethernet BUS (C) PUR(2x2x0,65) StC104303 RAL 6018 L TZE SUPERFLEX ethernet BUS (C) PUR(2x2x0,22) StC104304* For these cables use only our RJ45 / M12 connectorsDIOSWITCH Data rate 10/100 MBit/s DIN rail mounted Autonegotiation Autocrossing Supports Address Aging and base VLAN Rugged housing IP20 with 8 x RJ45 orIP67 with 8 x M12 DIOSWITCH MINI 6/8-Port- ethernet Switch for industrial use Data rate 10/100 MBit/s DIN rail mounted Autonegotiation Autocrossing Supports Address Aging and base VLAN 8 Port version: 8x RJ45 or 6 Port version.

5 4x RJ45 and 2 screw terminal connectionsStandard CAT5/5e/6 TypePart cables L TZE ELECTRONIC ethernet CAT5 UTP(4x2xAWG24/1) 100 MHZ104350(wiring cable for office L TZE ELECTRONIC ethernet CAT5 STP(4x2xAWG24/1) 100 MHZ104351environment) L TZE ELECTRONIC ethernet CAT5 STP-C (4x2xAWG24/1) 100 MHZ104352L TZE ELECTRONIC ethernet CAT5e UTP(4x2xAWG24/1) 200 MHZ104353L TZE ELECTRONIC ethernet CAT5e STP(4x2xAWG24/1) 200 MHZ104354L TZE ELECTRONIC ethernet CAT5e STP-C (4x2xAWG24/1) 200 MHZ104355L TZE ELECTRONIC ethernet CAT6 UTP(4x2xAWG23/1) 300 MHZ104356L TZE ELECTRONIC ethernet CAT6 STP(4x2xAWG23/1) 300 MHZ104357L TZE ELECTRONIC ethernet CAT6 STP-C (4x2xAWG23/1) 450 MHZ104358 Fibre optics and assemblies upon patch cables,Type Length / m DataPart , greyRJ45/RJ45 Straight grey* 0,5 CAT5/SFTP192000RJ45/RJ45 Straight grey*1 CAT5/SFTP192001RJ45/RJ45 Straight grey*2 CAT5/SFTP192002RJ45/RJ45 Straight grey*3 CAT5/SFTP192003RJ45/RJ45 Straight grey*5 CAT5/SFTP192004RJ45/RJ45 Straight grey*10 CAT5/SFTP192005RJ45/RJ45 Crossover red*0,5 CAT5/SFTP192050RJ45/RJ45 Crossover red* 1 CAT5/SFTP192051RJ45/RJ45 Crossover red* 2 CAT5/SFTP192052RJ45/RJ45 Crossover red* 3 CAT5/SFTP192053RJ45/RJ45 Crossover red*5 CAT5/SFTP192054RJ45/RJ45 Crossover red*10 CAT5/SFTP192055*Cable versions on Type Part rail patch box (2xRJ45 for 2 CAT5 cables)680500 DIN rail patch panel (4xRJ45)

6 680501 Cable assembliesOur abilities include: Design of customer specific ethernet connection cables No minimum order quantityConnectorsTypePart connector data for Superflex Bus ethernet cables 4 pole black IP20686011RJ45 connector push pull for Superflex Bus ethernet cables 4 pole black IP67686012RJ45 connector 3A data for Superflex Bus ethernet cables 4 pole black IP67686013RJ45 connector 3A data metal for Superflex Bus ethernet cables 4 pole IP67686014M12 connector 0 D coded for IP67 ethernet connections686072M12 connector 90 D coded for IP67 ethernet connections686073M12 IP67 Connectors, field wireableRJ45 IP67RJ45 IP20RJ45 IP67RJ45 IP67 DIN rail patch boxDeutschlandFriedrich L tze GmbH & Co. KGPostfach 1224 (PLZ 71366)Bruckwiesenstra e 17-19D-71384 WeinstadtTel.: + 49 (0)71 51 60 53-0 Fax: + 49 (0)71 51 60 tze systems for highest industrial standards: Prepopulated C-track systems L tze-LSC-wiring systems for all standard control panels Powerful modul- and interface-technology Reliable suppression technology Efficient power supplies Automation systems for rough surroundingsUSALUTZE South Ridge DriveCharlotte, NC 28273 Tel.

7 : +1 (704) 504-0222 Fax: +1 (704) 504 KingdomL TZE 3 Sandy Hill ParkSandy Way, AmingtonTamworth, Staffs, B77 4 DUTel.: + 44 (0)18 27 31333-0 Fax: + 44 (0)18 27 sterreichL TZE ElektrotechnischeErzeugnisse : + 43 (0)1 257 52 52-0 Fax: + 43 (0)1 257 52 TZE AGOststra e 2CH-8854 Siebnen/SZTel.: + 41 (0)55 450 23 23 Fax: + 41 (0)55 450 23 TZE l.: + 33 (0)1 34 18 77 00 Fax: + 33 (0)1 34 18 18 L tze GmbH & Co. KGTel.: + 39 039 928 49 36 Fax: + 39 039 59 95 aLUTZE, +34 679 96 56 D(GB)/GB Gress-Druck MS by Friedrich L tze GmbH & Co. KG, D-Weinstadt, Germany Subject to technical modification.


Related search queries