Example: barber

Construction Emergency Battery Pack Option Controls ...

Metalux Safe and convenient means of disconnecting powerCatalog # Type Date Project Comments Prepared by SPECIFICATION FEATURESC onstructionHousing consists of die formed cold rolled steel with decorative white opaque injection molded end plates. Reflector/channel wireway cover secured by fasteners for easy wireway access. Channel back has numerous KO s for easy installation. ControlsThe SWLED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting Controls and lighting relay panels to maximize energy savings. In addition, the SWLED can include a factory-installed integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote.

Metalux Safe and convenient means of disconnecting power Catalog # Type Date Project Comments Prepared by SPECIFICATION FEATURES Construction Housing consists of die formed

Tags:

  Construction, Emergency, Pack, Battery, Options, Construction emergency battery pack option

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Construction Emergency Battery Pack Option Controls ...

1 Metalux Safe and convenient means of disconnecting powerCatalog # Type Date Project Comments Prepared by SPECIFICATION FEATURESC onstructionHousing consists of die formed cold rolled steel with decorative white opaque injection molded end plates. Reflector/channel wireway cover secured by fasteners for easy wireway access. Channel back has numerous KO s for easy installation. ControlsThe SWLED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting Controls and lighting relay panels to maximize energy savings. In addition, the SWLED can include a factory-installed integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote.

2 Or, specify the Digital Addressable Lighting Interface (DALI) drivers (consult factory for 1% dimming), for use with Fifth Light Controls . See ordering information for details on all three LED system coupled with electrical driver to deliver optimal performance. LED s available in 3500K, 4000K or 5000K with a typical CRI 85. Projected life is 60,000 hours at 70% lumen output. Electronic drivers are available for 120-277V applications. A 0-10V dimming driver is Battery pack OptionOptional 120v-277v integral Emergency Battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant powerto the LED system, ensuring code-compliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the Battery during Construction .

3 See ordering information for reflective post painted finish (PAF) standard offering customers the optimal finish and handling. Additionally, each housing is treated in a multistage iron phosphate pretreatment, insuring maximum bonding and rust inhibitor. ShieldingSpecially designed LED lens blends and linear optics allows us to offer three different lens versions - LC (clear), LN (Semi-Frost with narrow distribution) and LW (full frost with wide distribution). This lenses provide different lighting distribution allowing customers to choice between smooth even illumination. Lens is securely held in place by removable injection molded white end caps that can be easily removed for installation and may be surface (wall or ceiling) and suspended mounted. See accessories below for ordering are UL recognized components and indoor luminaires are cULus listed for up to 40 C ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-80 standards.

4 DesignLights Consortium Qualified and classified for DLC Standard, refer to for and Wall LEDADF1423522016-09-27 07:58:10 SWLED is a versatile LED surface or wall mount luminaire which can be used in a broad range of commercial and industrial series provides customers with a high quality luminaire utilizing the latest LED, solid state lighting and electronic driver technology for optimal performance and maximized energy efficiency. Offered with three different lens distributions and three different lens options which provides uniform light distribution that is an ideal choice for general purpose lighting where customers want to move away from traditional fluorescent DATAcULus - 1598 Damp Location ListedLM79/LM80 CompliantROHS CompliantDesignLights Consortium QualifiedNOM Compliant4-11/16"[120mm]4-1/2" [114mm]4-11/16"[120mm]52" [1320mm]45-3/16" [1148mm]Lensed4'2'4-11/16"[120mm]21-3/16 " [538mm]Lensed28" [711mm]MOUNTING DATA DESIGN JOURNALPLATINUM2016 Specifications and dimensions subject to change without 1121 Highway 74 SouthPeachtree City, GA 30269P: 07:58.

5 10 Lens TypeLumen TypeLengthCatalog LogicNominal LumensWattagelm/WFull Frost (LW)Standard2 Frost (LW)Standard2 Frost (LW)Standard2 Frost (LW)High2 Frost (LW)High2 Frost (LW)Standard4 Frost (LW)Standard4 Frost (LW)Standard4 Frost (LW)Standard4 Frost (LW)Standard4 Frost (LW)Standard4 Frost (LW)High4 Frost (LW)High4 Frost (LW)High4 0 Full Frost (LW)High4 Frost (LW)High4 Frost (LW)High4 Frost (LW)High4 and dimensions subject to change without 1121 Highway 74 SouthPeachtree City, GA 30269P: (13)SWLED=LED Surface and WallSAMPLE NUMBER: 4 SWLED-LD4-40SL-LW-UNV-L840-CD1-SVPD2-ULE D TypeLD4=LED 4. 0 LED Lumens Output (2)8SL=800 (3)16SL=1600 (3)20SL=200024HL=2400 (3)28HL=2800 (3)28SL=2800 (4)32SL=320036SL=360040SL=400044HL=44004 8HL=480052HL=5200 (12)56HL=5600 (12)60HL=6000 (12)64HL=6400 (12)67HL=6700 (12), (16)72HL=7200 (12), (16)78HL=7800 (12), (16)80HL=8000 (12), (17)Voltage347V=347 Volt (11)480V=480 Volt (11)UNV=UniversalVoltage 120-277 (1)UNC=UniversalVoltage347/480 (4), (11) Driver TypeCD=0-10V Dimming DriverHCD=0-10V Dimming Driver(1% - 100% Dimming) (11)SD=Step-dim Driver (19), (20)5 LTD=Fifth Light (DALI) DriverNumber of Drivers1=1 Driver2=2 DriversOpticLC=Clear Lens LN=Semi-Frost Lens - Narrow LW=Full Frost Lens - Wide Length2=2 ft.

6 Length4=4 ft. LengthNOTES: (1) Not available when specifying emergencies, voltage must be specific. (2) Nominal lumen output. (3) 2 ft. model. (4) Only available in 4 ft. models. (5) With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the Emergency Battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under Emergency operation available. (6) For mounting heights up to 8 ft. (7) For mounting heights up to 30 ft. (8) For mounting heights up to 12 ft. (9) Integral EL Battery pack is rated for 35 C. (10) Product configuration meet ADA. (11) Consult factory. (12) Currently not DLC listed, consult factory. (13) DesignLights Consortium Qualified and classified for DLC Standard (some models are not DLC qualified), refer to for details.

7 (14)For wall mount applications. (15)For use with CD driver only. (16)Lumen value with LN (30% Frost lens). (17)Lumen value with LC (Clear lens). (18)Used to transfer fixture to secondary power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under Emergency power. (19)4 ft. model only. (20)4000 and & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering (4), (9)EL7W=7-watt, 120V-277V Emergency Battery pack installed (5)EL14W=14-watt 120V-277V Emergency Battery pack installed (5)GTD2=Bodine Generator Transfer Device (18) ETS2=IOTA Emergency Transfer Switch (18) CCTL835=3500KL840=4000KL850=5000 KOccupancy SensorSVPD1=Integrated occupancyand daylight dimming sensor,500 sq.

8 Ft. coverage (6), (8), (10), (15)SVPD2=Integrated occupancy anddaylight dimming sensor,900 sq. ft. coverage (8), (14), (15)SVPD3=Integrated occupancy anddaylight dimming sensor,1200 sq. ft. coverage (7), (15)PackagingU=Unit PackACCESSORIES(Order Separately)SCF=Fixed Stem Set (Specify Length)SCS=Swivel Stem Set (Specify Length)SCA=Adjustable 48" Stem SetA1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 Per Fixture) ISHH-01=Programming Remote for Integrated SensorISHH-02=Personal Control Remote for Integrated SensorORDERING INFORMATION4 SWLED-LD4-40SL-LW-UNV-L835-CD1 Electronic DriverLinear LED 3500 KSpacing criterion: (II) x mounting height, ( ) x mounting heightLumens: 4087 Input Watts: cacy: lm/WTest Report: II45 Across 1194 1194 11941203 11 88 11 7311 84 11 59 11 4211 53 11 23 11101110 1080 10741058 1032 1031996 978 983926 918 933849 855 878766 786 816678 713 754588 639 690495 564 626400 491 563302 419 503207 352 445125 291 39055 236 3374 188 285 Coefficients of UtilizationEffective fl oor cavity refl ectance 20%rc80%70%50%30%10%0%rw7050301070503010 503010503010503010 0 RCR01234567891011 7 11 7 11 7 11 7 11 3 11 3 11 3 11 3 106 106 106 10 0 10 0 10 0 94 94 94 91105 99 94 90 101 96 91 87 90 86 83 85 82 79 80 77 75 7295 85 78 71 91 83 76 70 78 72 67 73 68 64 69 65 61 5986 74 66 59 82 72 64 58 68 61 55 64 58 53 60 56 51 4978 66 56 49 75 64 55 49 60 53 47 57 50 45 54 48 44 4172 58 49 42 69

9 57 48 42 54 46 40 51 44 39 48 42 38 3566 53 43 37 64 51 42 36 48 41 35 46 39 34 44 38 33 3161 48 39 32 59 46 38 32 44 36 31 42 35 30 40 34 29 2757 43 35 29 55 42 34 28 40 33 28 38 32 27 36 31 26 2453 40 31 26 51 39 31 25 37 30 25 35 29 24 34 28 24 2250 37 29 23 48 36 28 23 34 27 22 33 26 22 31 26 21 20 Zonal Lumen SummaryZoneLumens% Fixture0-300-400-600-900-180905 10 15 30 45 60 75 90 9001350 PHOTOMETRICSADF1423522016-09-27 07:58:10 Catalog No. 6 12 DATAS pecifications and dimensions subject to change without 1121 Highway 74 SouthPeachtree City, GA 30269P: SWLED with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Tr aditionally, these types of energy savings required coordination between the luminaire and a lighting control system.

10 The SWLED delivers superior lighting with integrated occupancy and daylighting Controls . Capture the benefits of traditional lighting Controls , without complicated coverage planning or special wiring. Ideal for new Construction or retrofit, the SWLED delivers automatic ON to an energy saving light level, ensuring lighting is turned OFF when the space is integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control. The SWLED with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings.


Related search queries