VSD03M - SOLENOID OPERATED DIRECTIONAL VALVES5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: / HYDRAULICSSOLENOID OPERATED DIRECTIONAL - - SOLENOID OPERATED DIRECTIONAL VALVESVSD03 MSOLENOID OPERATED DIRECTIONAL VALVESDESCRIPTIONT hese valves conform to NFPA D03 and ISO 4401 mounting standards. They are available in both 3 way and 4 way versions are available in 2 position spring offset, 2 position detent, 2 position spring centered and 3 position spring centered wide range of spools are and CSA approved versions are PERFORMANCE SPECIFICATIONSMAXIMUM OPERATINGPRESSUREP - A - B Ports Standard5000 psi350 barCSA4000 psi275 barT Port Standard3000 psi210 barCSA2500 psi172 barFLOW RATE20 gpm76 l/minMOUNTING SURFACENFPA D03 ISO 4401-03-02-0-03 MAXIMUMWEIGHTAC4 kgRANGE TEMPERATURESA mbient - 4 to +130 F-20 to +54 CFluidStandard- 4 to +180 F-20 to +82 CCSA-4 to +150 F-20 to +66 CFLUID VISCOSITYR ange60 -1900 SUS10 - 400 cStRecommended120 SUS25 cStFLUID CONTAMINATIONISO 4406.

2 www.continentalhydraulics.com - sales@conthyd.com powerful vsd03m - solenoid operated directional valves vsd03m solenoid operated directional valves

Tags:

  Hydraulic, Continental, Continental hydraulics, Continentalhydraulics

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CONTINENTAL HYDRAULICS VSD03M

1 VSD03M - SOLENOID OPERATED DIRECTIONAL VALVES5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: / HYDRAULICSSOLENOID OPERATED DIRECTIONAL - - SOLENOID OPERATED DIRECTIONAL VALVESVSD03 MSOLENOID OPERATED DIRECTIONAL VALVESDESCRIPTIONT hese valves conform to NFPA D03 and ISO 4401 mounting standards. They are available in both 3 way and 4 way versions are available in 2 position spring offset, 2 position detent, 2 position spring centered and 3 position spring centered wide range of spools are and CSA approved versions are PERFORMANCE SPECIFICATIONSMAXIMUM OPERATINGPRESSUREP - A - B Ports Standard5000 psi350 barCSA4000 psi275 barT Port Standard3000 psi210 barCSA2500 psi172 barFLOW RATE20 gpm76 l/minMOUNTING SURFACENFPA D03 ISO 4401-03-02-0-03 MAXIMUMWEIGHTAC4 kgRANGE TEMPERATURESA mbient - 4 to +130 F-20 to +54 CFluidStandard- 4 to +180 F-20 to +82 CCSA-4 to +150 F-20 to +66 CFLUID VISCOSITYR ange60 -1900 SUS10 - 400 cStRecommended120 SUS25 cStFLUID CONTAMINATIONISO 4406.

2 1999 Class - (STD)GVitonMECHANICALOMIT IF NOT REQUIREDRS ingle Solenoid Operator At B Port End. WDWash-DownCONNECTION BOX OPTIONSOMIT IF NOT REQUIREDSee the codes on page 9 ELECTRICAL OPTIONOMITPlug-in terminalsolenoids or lead wiresBConnection box with terminal posts and lightsVSD03M -L ----TYPICAL ORDERING CODE: VSD03M -3A-AB5A-60L-C VSD03M -3A-A-33L-CIDENTIFICATION CODEDESIGN LETTERS pool TypeSee Next PageSOLENOIDS - See the codes on page 10 VSD03M - SOLENOID OPERATED DIRECTIONAL VALVESFUNCTION1 Single Solenoid 2 PositionSpring Offset2 Dual Solenoid 2 PositionDetented (No Spring)3 Dual Solenoid 3 PositionSpring Centered5 Single Solenoid 2 PositionSpring Centered6 Single Solenoid 2 PositionEnergize To Center9 Single Operator 2 Position - 3 WaySpring OffsetAPPROVALSOMITSTD VALVECSACSA - - SOLENOID OPERATED DIRECTIONAL VALVESSPOOLSNAMESYMBOLFUNCTIONCENTER POSITIONCROSSOVERFUNCTION MATCHINGAAll ports blockedP B or P A T blocked1, 2, 3, 5, 6A1 All ports blockedP B and A T restricted or P A and B T restricted3, 5 BAll ports openAll ports open1, 2, 3, 5, 6EP and A blocked, and B TAll ports blocked or P and A blocked and B T3, 5E1P and A blocked, B restricted to TAll ports blocked or A blocked and B T restricted3, 5FP blocked, A T and B TP blocked and A T or B T3, 5, 6F1P blocked.

3 A and B restricted to TP blocked, A or B restricted to T3, 5GP to A and B T blockedP B or P A T blockedHP and A to T,B blockedAll ports open, restrictedJP B A and T blockedP B and A blocked or all ports blockedKP and B blocked, and A TP and B blocked and A T or all ports blockedK1P and B blocked, A restricted to TP blocked and A T restricted or all ports blockedLP T, A and B blockedAll ports open, restrictedNP A B and T blockedAll ports blocked, or P A B and T blocked3, 5, 6QP and B to T,A blockedAll ports open, restricted3, 5X-All ports blocked9AN-All ports blocked2AJ-All ports blocked2 These are the standard configurations. Contact CONTINENTAL HYDRAULICS for special - - SOLENOID OPERATED DIRECTIONAL VALVESPRESSURE DROPS P-Q(OBTAINED WITH VISCOSITY OF 170 SUS - 36 CST AT 70 F - 50 C)PERFORMANCE CURVESPOOLFLOW CURVE NUMBERSHIFTEDCENTERP AP BA TB TP TA, A1, K1, F1, E12233B11332E2231F3311G1313H, Q45553J2133K2213L55553N12331A, 2A, 2AN, 2AJ33331A, 1B, 2A22229X33 CURVESPOOL1A, 2A, A1, AN, AJ, E1, G, K1, J, N, X 2F13H, L, Q, B4F51A61B, E, KDC - - SOLENOID OPERATED DIRECTIONAL VALVESNOTES:1.

4 The values indicated in the graphs are relevant to the standard solenoid valve, with 42L coils. 2. Valve performance was tested in a four way circuit (full loop). Performances may be reduced from that shown when used in a three-way circuit (half circuit), A or B port The values have been obtained according to ISO 6403 norm with solenoids at rated temperature and supplied with voltage equal to 90% of the nominal voltage. The value have been obtained with filtration according to ISO 4406:1999 class 18/16 CURVECURVESPOOL1A, A1, G, AN, AJ, , H, Q5J, N6F1, E1, K17K, ECURVESPOOL12A, AN, B21A, 1B, G3A4A15L6 FAC VOLTAGEAC VOLTAGE - LOW - - SOLENOID OPERATED DIRECTIONAL VALVES OVERALL AND MOUNTING DIMENSIONS - CONNECTION BOX VERSIOND imensions in mm [IN] VSD03M -2*, 3*Mounting surface with sealing rings:4 pcs.

5 AS568-012 90 Shore AAC Coil Shape: SquareConnection Box Manual OverrideIntegrated in the OverrideIntegrated in the Removal SpaceCoil Removal SpaceDC Coil Shape: RoundSOL. A SOL. B SOL. B VSD03M -1*, 5*, 6*, 9* - - SOLENOID OPERATED DIRECTIONAL VALVES OVERALL AND MOUNTING DIMENSIONS - DIN STYLE VERSIOND imensions in mm [IN] VSD03M -2*, 3* VSD03M -1*, 5*, 6*, 9*Mounting surfacewith sealingrings: 4 90 Shore ACoil with DIN style shape (DIN 43650) ConnectorDC Coil Shape: RoundAC Coil Shape: SquareCoil Removal SpaceCoil Removal SpaceSOL. A SOL. B Manual OverrideIntegrated in the OverrideIntegrated in the - - SOLENOID OPERATED DIRECTIONAL VALVESELECTRICAL CHARACTERISTICSV alves are available with an electrical connection box or with DIN 43650 solenoids in both AC andDC voltages.

6 Deutsch DT04 or lead wires are also available in DC voltages BOX OPTIONSTo simplify the connections and prevent wiring mistakes, we offer the option with connection boxes with quick connect pin receptacles, already are available with receptacles on solenoid side A or B and several connector are the codes to be included in the box option of the ordering code, depending on theversion you diagrams at right show the standard connections for 3-pin, 4-pin and 5-pin connectors. Thecommercially available mating female connector are not ENDNOTES5A5 Male MiniASingle and DualSolenoid5H5B3A3 Male MiniASingle Solenoid Only3H3B4A4 Male MicroAFor DC Current Only. Different PIN RECEPTACLEMale mini receptacles conform to R1 - 2007 used with single or double solenoid mm [1 ] Wrench3 PIN RECEPTACLEMale mini receptacles conform to R1 - 2007 used with single solenoid mm [1 ] Wrench4 PIN RECEPTACLEMale micro receptacles (M12x1 thread) used with DC valve mm [7/8] Wrench1 Lead to Solenoid B2 Lead to Solenoid A3 Ground Lead (Green)4 Lead to Solenoid A5 Lead to Solenoid B1 Ground Lead (Green)2 Lead to Solenoid3 Lead to Solenoid4A & 41 BrownLead to Solenoid A2 WhiteNo Connection3 BlueCommon Lead to Sol.

7 A & B4 BlackLead to Solendoid BD4A & D41 BrownNo Connection2 WhiteLead to Solenoid A3 BlueCommon Lead to Sol. A & B4 BlackLead to Solendoid - - SOLENOID OPERATED DIRECTIONAL VALVESDEUTSCH DT04 MALELEAD WIRESSOLENOIDSL isted below the types of solenoids available and the numbers to be added in the solenoid box on page TERMINAL SOLENOID DIN 43650 This solenoid has three terminal posts. Use bi-polar connectors that meet ISO 4400 / DIN 43650(EN 175301-803). Protection against atmospheric agent: IP 65 LEAD WIRES6 inch length, protection against atmospheric agent: IP 67 DEUTSCH DT04 MALEP rotection against atmospheric agent: IP 69 Connectors must be ordered BOX SOLENOIDS This is a two pin solenoid which connects to the circuit board.

8 Wiring is done on the terminal stripinside the OPTION (CODE WD)The wash-down option with the electrical box is designed for an IP65 rating. This option uses a special cover without the mounting bolt access holes and uses silicone sealant to help seal between the coil and core tube. The DIN, Deutsch and lead wire coils versions of the wash-down option uses silicone sealant to help seal between the coil and core CONNECTIONCODELEAD WIRE CONNECTIONCODEDEUTSCH DT04 CONNECTION CODEBOX CONNECTIONCODEVOLTAGE & FREQ.[VOLT - HERTZ]VOLTAGE LIMITS[MIN - MAX]RESISTANCE 10%[OHM]INRUSH CURRENT[A]HOLDING CURRENT[A]HOLDING POWER[W]33 Not AvailableNot Available60120 - 60110 - 50108 - 12699 - AvailableNot Available61240 - 60 220 - 50 216 - 252198 - AvailableNot AvailableNot Available68120 - 60110 - 50108 - 13299 - V DC21 - V DC10 - - - SOLENOID OPERATED DIRECTIONAL VALVESAPPLICATION DATAFLUIDS All pressure drops shown on these data pages are based on 170 SUS fluid viscosity and specific gravity.

9 For any other specific gravity (G1) the pressure drop ( P) will be approx. P1 = P (G1/G). See the chart for other mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type (phosphate esters) use FPM seals (code G). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical fluids at temperatures higher than 180 degrees F causes the accelerated degradation of seals as well as degradation of the fluids physical and chemical a safety standpoint, temperatures above 130 degrees F are not with centering and return springs can be mounted in any position without impairing correct operation. Valves with mechanical detent should have horizontal are fixed by means of screws or tie rods on a flat surface with planarity and roughness equal to or better than those indicated in the relative symbols.

10 If minimum values are not observed, fluid can easily leak between the valve and support TEMPERATURES: Ambient - 4 to +130 F-20 to +54 CFluidSTD- 4 to +180 F-20 to +82 CCSA- 4 to +150 F-20 to +66 CFLUID VISCOSITYR ange60 -1900 SUS10 - 400 cStRecommended120 SUS25 cStFLUID CONTAMINATIONISO 4406:1999 Class 20/18/15 SEAL KITBOLT KITBuna Seal Kit1013326 Viton Seal Sit1013327 VSD03M121472 VSD03M - SOLENOID OPERATED DIRECTIONAL VALVESFORM NO. 1013887. REV. 09/2013. 2011 CONTINENTAL HYDRAULICS . ALL RIGHTS RESERVED. PRODUCT SPECIFICATIONS AND APPEARANCE ARE SUBJECT TO CHANGE WITHOUT CONTINENTAL HYDRAULICSR ugged, durable, high-performance, ef cient the reason CONTINENTAL HYDRAULICS products are used in some of the most challenging applications across the globe.