0393 TRemoval of esophageal sphincter augmentation device0394 THigh dose rate electronic brachytherapy, skin surface application, per fraction, includes basicdosimetry, when performed0395 THigh dose rate electronic brachytherapy, interstitial or intracavitary treatment, per fraction,includes basic dosimetry, when performed0396 TIntra-operative use of kinetic balance sensor for implant stability during knee replacementarthroplasty (List separately in addition to code for primary procedure)0397 TEndoscopic retrograde cholangiopancreatography (ERCP), with optical endomicroscopy (Listseparately in addition to code for primary procedure)0398 TMagnetic resonance image guided high intensity focused ultrasound (MRgFUS), stereotacticablation lesion, intracranial for movement disorder including stereotactic navigation and frameplacement when performed0399 TMyocardial strain imaging (quantitative assessment of myocardial mechanics using image-based analysis of local myocardial dynamics) (List separately in addition to code for primaryprocedu)

separately in addition to code for primary procedure) ... 2015 2016 Code Descriptor Change Crosswalk Code ... CPT® 2016 Code Changes ...

Tags:

  Code, 2016, Change, Procedures, 2015, Crosswalk, Code crosswalk, 2016 code changes

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of CPT® 2016 Code Changes - Medtron …

1 0393 TRemoval of esophageal sphincter augmentation device0394 THigh dose rate electronic brachytherapy, skin surface application, per fraction, includes basicdosimetry, when performed0395 THigh dose rate electronic brachytherapy, interstitial or intracavitary treatment, per fraction,includes basic dosimetry, when performed0396 TIntra-operative use of kinetic balance sensor for implant stability during knee replacementarthroplasty (List separately in addition to code for primary procedure)0397 TEndoscopic retrograde cholangiopancreatography (ERCP), with optical endomicroscopy (Listseparately in addition to code for primary procedure)0398 TMagnetic resonance image guided high intensity focused ultrasound (MRgFUS), stereotacticablation lesion, intracranial for movement disorder including stereotactic navigation and frameplacement when performed0399 TMyocardial strain imaging (quantitative assessment of myocardial mechanics using image-based analysis of local myocardial dynamics) (List separately in addition to code for primaryprocedure)0400 TMulti-spectral digital skin lesion analysis of clinically atypical cutaneous pigmented lesions fordetection of melanomas and high risk melanocytic atypia.

2 One to five lesions0401 TMulti-spectral digital skin lesion analysis of clinically atypical cutaneous pigmented lesions fordetection of melanomas and high risk melanocytic atypia; six or more lesions0402 TCollagen cross-linking of cornea (including removal of the corneal epithelium and intraoperativepachymetry when performed)0403 TPreventive behavior change , intensive program of prevention of diabetes using a standardizeddiabetes prevention program curriculum, provided to individuals in a group setting, minimum 60minutes, per day0404 TTranscervical uterine fibroid(s) ablation with ultrasound guidance, radiofrequency0405 TOversight of the care of an extracorporeal liver assist system patient requiring review of status,review of laboratories and other studies, and revision of orders and liver assist care plan (asappropriate)

3 , within a calendar month, 30 minutes or more of non-face-to-face time0406 TNasal endoscopy, surgical, ethmoid sinus, placement of drug eluting implant0407 TNasal endoscopy, surgical, ethmoid sinus, placement of drug eluting implant; with biopsy,polypectomy or debridement20152016 CodeDescriptorChangeCrosswalkCodeDescrip torAdvice0099 TImplantation ofintrastromal corneal ringsegmentsDeleted(0099T hasbeen report, use65785) The 2016 code set deleted 0099 Tfor the implantation of intrastromalcorneal ring segments. This is aCategory III code , which is atemporary code used to allow fordata collection specific to emergingtechnology, services, or advises that this code is nowreportable using a new Category Icode 65785-Implantation ofintrastromal corneal ring ,quantitativeDeletedThe AMAdoes notprovidecrosswalkcodes for thisdeleted code The 2016 code set deleted 0103 Tused for an in vitro diagnostic test toquantitatively measureholotranscobalamin, or Holo TC, theamount of vitamin B12 in humanserum or plasma.

4 This is a CategoryIII code , which is a temporary codeused to allow for data collectionspecific to emerging technology,services or procedures . This codehas not been accepted forplacement in the Category I sectionof CPT and is not being , 0103T is being removedfrom CPT .0123 TFistulization of sclera forglaucoma, throughciliary bodyDeletedThe AMAdoes notprovidecrosswalkcodes for thisdeleted code The 2016 code set deleted 0123 Treported when athermocauterization device is usedto create an opening in the backchamber of the eye from the scleraand through the ciliary body to drainthe aqueous humor. This is aCategory III code , which is atemporary code used to allow fordata collection specific to emergingtechnology, services or code has not been accepted forplacement in the Category I sectionof CPT and is not being , 0123T is being removedfrom CPT.

5 0182 THigh dose rateelectronicbrachytherapy, perfractionDeleted(0182T hasbeen deleted,To report, see0394T, 0395T) The 2016 code set deleted code0182T reported for the placement ofa minute, high dose rate, or HDR, X-ray source near the tumor site in thebody. This is a Category III code ,which is a temporary code used toallow for data collection specific toemerging technology, services orprocedures. CPT advises that thiscode is now reportable using twonew temporary codes, 0394T toreport HDR electronic skinbrachytherapy, and 0395T to reportHDR electronic interstitial orintracavitary treatments. Note thatthe new codes include the workassociated with the basic dosimetrycalculation when cardiography,including automatedanalysis of combinedacoustic and electricalintervals; single, withinterpretation and reportDeleted(0223T,0224T, 0225 Thave beendeleted.)

6 Toreportacousticcardiography,use 93799) The 2016 code set deleted 0223 Tfor the correlation of systolic anddiastolic heart sounds with anelectrocardiograph, or ECG, tracingto evaluate heart function or bloodcirculation. This is a Category IIIcode, which is a temporary codeused to allow for data collectionspecific to emerging technology,services or procedures . CPT advises that this code has not beenaccepted for placement in theCategory I section of CPT and isnot being retained. Therefore, 0223 Tis being removed from CPT .0224 TAcoustic cardiography,including automatedanalysis of combinedacoustic and electricalintervals; multiple,including serial trendedanalysis and limitedreprogramming ofdevice parameter, AV orVV delays only, withinterpretation and reportDeleted(0223T,0224T, 0225 Thave beendeleted.

7 Toreportacousticcardiography,use 93799) The 2016 code set deleted 0224 Tfor multiple correlations of systolicand diastolic heart sounds with anelectrocardiograph, or ECG, tracingto evaluate heart function or bloodcirculation. This is a Category IIIcode, which is a temporary codeused to allow for data collectionspecific to emerging technology,services or procedures . CPT advises that this code has not beenaccepted for placement in theCategory I section of CPT and isnot being retained. Therefore,0224T is being removed fromCPT .0225 TAcoustic cardiography,including automatedanalysis of combinedacoustic and electricalintervals; multiple,including serial trendedanalysis and limitedreprogramming ofdevice parameter, AVand VV delays, withinterpretation and reportDeleted(0223T,0224T, 0225 Thave beendeleted.

8 Toreportacousticcardiography,use 93799) The 2016 code set deleted 0225 Tfor multiple correlations of systolicand diastolic heart sounds with anelectrocardiograph, or ECG, tracingto evaluate heart function or bloodcirculation, and serial analyses withatrioventricular and interventriculardelay and limited reprogramming ofthe device parameters, or is a Category III code , which isa temporary code used to allow fordata collection specific to emergingtechnology, services or advises that this code has notbeen accepted for placement in theCategory I section of CPT and isnot being retained. Therefore,0225T is being removed fromCPT .0233 TSkin advanced glycationendproducts (AGE)measurement by multi-wavelength fluorescentspectroscopyDeleted(0233T hasbeen report skinadvancedglycationendproductsmeasurem entby multi-wavelengthfluorescentspectroscopy, use 88749) The 2016 code set deleted 0233 Tfor the measurement of the skinfluoresce due to depositedadvanced glycation is a Category III code , which isa temporary code used to allow fordata collection specific to emergingtechnology, services or advises that this code has notbeen accepted for placement in theCategory I section of CPT and isnot being retained.

9 Therefore,0233T is being removed fromCPT .0240 TEsophageal motility(manometric study ofthe esophagus and/orgastroesophagealjunction) study withinterpretation andreport; with highresolution esophagealpressure topographyDeletedThe AMAdoes notprovidecrosswalkcodes for thisdeleted code The 2016 code set deleted 0240 Tfor a manometric study of theesophagus and or the junctionbetween the esophagus and thestomach to measure musclepressure and movement,coordination, and strength of theesophageal contractions. This is aCategory III code , which is atemporary code used to allow fordata collection specific to emergingtechnology, services or advises that this code has notbeen accepted for placement in theCategory I section of CPT and isnot being retained.

10 Therefore,0240T is being removed fromCPT .0241 TEsophageal motility(manometric study ofthe esophagus and/orgastroesophagealjunction) study withinterpretation andreport; with stimulationor perfusion during highresolution esophagealpressure topographystudy (eg, stimulant,acid or alkali perfusion)(List separately inaddition to code forprimary procedure)DeletedThe AMAdoes notprovidecrosswalkcodes for thisdeleted code The 2016 code set deleted 0241T amanometric study of the esophagusand or the junction between theesophagus and the stomach tomeasure muscle pressure andmovement, coordination, andstrength of the esophagealcontractions with stimulation orperfusion during high resolutionesophageal pressure topographystudy.