Example: quiz answers

Dens-Glass Gold Sheathing - Dryvit

Dens-Glass gold Sheathing Most exterior sidings and wall coverings . MANUFACTURER including wood, vinyl, composition, metal, TECHNICAL DATA. stone, brick, stucco, wood shingles, shakes G-P gypsum Corporation Dens-Glass gold exceeds ASTM E 283 and and plywood panels may be applied 133 Peachtree Street, E 331 test criteria for both Air Infiltration and directly over Dens-Glass gold Sheathing Atlanta, GA 30303 Static Water penetration with approved joint with excellent results. Building felt is often Technical 1 (800) 225-6119 (EST) finish methods as alternates to building felts. not always necessary; consult local building codes for joint treatment alternatives and Dens-Glass gold panels provide 0 flame DESCRIPTION building felt requirements.

MANUFACTURER G-P Gypsum Corporation 133 Peachtree Street, N.E. Atlanta, GA 30303 Technical 1 (800) 225-6119 (EST) DESCRIPTION Dens-Glass® Gold is a unique, ‘‘paperless’’ sheathing panel made of a patented water

Tags:

  Glass, Gold, Ends, Sheathing, Gypsum, Dens glass gold sheathing

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Dens-Glass Gold Sheathing - Dryvit

1 Dens-Glass gold Sheathing Most exterior sidings and wall coverings . MANUFACTURER including wood, vinyl, composition, metal, TECHNICAL DATA. stone, brick, stucco, wood shingles, shakes G-P gypsum Corporation Dens-Glass gold exceeds ASTM E 283 and and plywood panels may be applied 133 Peachtree Street, E 331 test criteria for both Air Infiltration and directly over Dens-Glass gold Sheathing Atlanta, GA 30303 Static Water penetration with approved joint with excellent results. Building felt is often Technical 1 (800) 225-6119 (EST) finish methods as alternates to building felts. not always necessary; consult local building codes for joint treatment alternatives and Dens-Glass gold panels provide 0 flame DESCRIPTION building felt requirements.

2 Spread, 0 smoke developed when tested in accordance with ASTM E 84. Noncombustible Dens-Glass gold is an ideal product for Dens-Glass gold is a unique, paperless''.. when tested in accordance with ASTM E 136. exterior ceilings and soffits for both cold Sheathing panel made of a patented water and warm climate zones. It resists sagging, Dens-Glass gold exceeds ASTM C 79. resistant and silicone-treated core, surfaced even under exceptionally humid conditions. standards for humidified deflection by a with glass mat facings and a gold '' colored Panels are applied directly to structural fram- factor of 10 in tests over the standard for alkali-resistant coating. Providing superb pro- ing.

3 Surface and joints may be finished and regular gypsum Sheathing . tection from the elements, Dens-Glass gold painted, or the ceiling/soffit may be surfaced panels are highly resistant to delamination Dens-Glass gold Fireguard qualifies with an exterior finish system. and deterioration due to weather. for a one-hour fire resistant construction (UL U337) when tested in accordance Dens-Glass gold exhibits 50-100% greater LIMITATIONS with ASTM E 119, and is UL classified. flexural strength than regular gypsum sheath- Dens-Glass gold must be installed yellow ing, with a dimensional stability that assures Dens-Glass gold conforms to ASTM C 117. side facing out, according to specified resistance to warping, rippling, buckling manufacturer's guidelines, applicable code and sagging for a flat and even substrate.

4 Dens-Glass gold is noncombustible, with requirements and applicable details found in INSTALLATION. the gypsum Association publication GA-253. tests showing no flame spread or smoke 1. The surface of framing and furring mem- development. Since Dens-Glass gold panels Dens-Glass gold is designed to be a com- bers to receive Dens-Glass gold should are strong in both directions, they may be ponent in properly designed cladding or not vary more than 1 4 from the plane of installed either vertically or horizontally to exterior system. The suitability and com- faces of adjacent members. framing members. patibility of Dens-Glass gold as part of any system is the responsibility of the 2.

5 End joints, if required, should be offset;. system manufacturer. A weather barrier joints should fit snugly and flashing PRIMARY USES cladding must be applied prior to the installed around all openings. expiration of the six (6) months exposure. Because of the superior performance of 3. Dens-Glass gold panels of the maximum Dens-Glass gold , it is specified for exterior Do not use a vapor barrier on the exterior lengths possible should be used to mini- walls, ceilings and soffits in a wide variety wall behind Dens-Glass gold in DEFS mize the number of joints. Edge joints of applications. These include exterior finish installations. (Use vapor permeable weather must be located parallel to and with verti- systems with insulation (EIFS); cavity walls barrier.)

6 Cal orientations on framing. End joints of in brick veneer applications; direct exterior adjacent lengths of Dens-Glass gold must Do not use Dens-Glass gold as a base for finish systems without insulation (DEFS) for be staggered. nailing or mechanical fastening. When used areas with minimal freeze-thaw cycles;. in a soffit application, moisture should not 4. Dens-Glass gold must be attached to cladding such as wood siding, vinyl siding, be allowed to settle or pond on the top of wood framing with nails spaced 4 composition siding, siding, wood shingles, Dens-Glass gold . at perimeter for racking shear resistance, shakes, stone, brick, conventional stucco 8 at perimeter where racking shear systems and plywood siding panels requir- In all applications, coatings and sealants resistance is not required, and 8 ing a single-ply backing; and interior finish must be properly and sufficiently applied in field.

7 Systems that require a substrate panel with to protect Dens-Glass gold from excessive superior fire and moisture resistance. moisture. 5. For metal framing installations, Dens- glass gold must be attached to metal For EIFS applications, Dens-Glass gold Dens-Glass gold should not be laminated to framing with screws spaced 8 at gypsum Sheathing is an ideal substrate for masonry surfaces; use furring strips or fram- perimeter and 8 in field. adhesive or mechanical application of ing spaced at manufacturer's specifications. expanded polystyrene (EPS) or extruded 6. Fasteners must be driven so as to bear Dens-Glass gold may be used in DEFS. polystyrene insulation, and is recommended tight against and flush with surface of (direct applied) exterior wall applications in in all climate zones.

8 Sheathing . Fasteners must NOT be approved areas. countersunk. Dens-Glass gold is an excellent substrate Dens-Glass gold should not be applied for DEFS applications in areas with minimal 7. Fasteners must be located a minimum below grade. freeze-thaw cycles, and will not delaminate of 3 8 from edges and ends of Sheathing or deteriorate due to weather even during panels. construction delays lasting as long as six months under appropriate storage conditions. SUBMITTAL APPROVALS: (Stamps or Signatures). 1 2 5 8 , type X. 8. Where Dens-Glass gold is used in 10. If required, building paper or equal should Lengths: 8 , 9 or 10 standard, applications involving veneer systems, be installed with flashing around open- tolerance +1 4.

9 Any joint treatment required should be in ings. For DEFS, a secondary weather Other lengths available upon request accordance with Sheathing manufacturer's barrier (not a vapor barrier) should be instructions and requirements of local applied behind Dens-Glass gold . Edges: Square governing authorities. Conforms to ASTM C 1177, glass Mat 9. Where Dens-Glass gold is used in gypsum Substrate for Use as Sheathing . applications of painted ceilings and PRODUCT DATA. soffits, joint tape must be applied over Thicknesses: 1 2 joints and embedded in a specified, 5. 8 Fireguard . setting type joint compound. For smooth Width: 4 1220mm standard, tolerance finish, the surface should be skim coated up to 1 8.

10 With joint compound. PHYSICAL PROPERTIES. PROPERTIES 1. 2 Dens-Glass gold Sheathing 5. 8 Dens-Glass gold FIREGUARD , TYPE X. Thickness, nominal inches 1. 2 5. 8 . Width, nominal 4 8 1. 4 1 8 . Length, standard 8 , 9 , 10 4 1. 8 , 9 , 10 1 4 . Weight, sq. ft., nominal 1900 2500. Surfacing glass fiber mat glass fiber mat Racking strength, (dry). (Ultimate not design value) 617 711. Flexural strength, parallel, lbs. (4 direction) 807 1007. Humidified deflection , inches 2. 8 7 1. 8 7. Surface Water Absorption, grams 4..84 .73. Permeance (perms)5 23 12. R value6 .56 .67. Flame Spread/Smoke Developed 0 0. Linear verification with change in moisture in/in/%RH x 10 6 x 10 6.