DS107 OUTSULATION An Exterior Wall insulation and Finish System That Incorporates Continuous insulation OUTSULATION System Installation Details NOTEDETAIL TABLE OF CONTENTSDETAIL OUTSULATION SystemOUTSULATION SYSTEM OS PREPARATION- OS AQUAFLASH SYSTEM OPTIONINSIDE/OUTSIDE CORNERSOS CORNER - HIGH IMPACTOS TERMINATIONOS AT CONCRETE CURBOS AT OS ADA COMPLIANT SIDEWALKEPS PREPARATION ATOS WALL PENETRATIONSPREPARATION OF OPENING FOROS STOREFRONT WINDOWPREPARATION OF OPENING FOROS nail -ON WINDOWWINDOW HEAD OS AT OS WOOD FRAMED DECKTERMINATION AT OS WATERPROOF DECKPREPARATION AT PARAPET/OS WALL INTERSECTIONTERMINATION AT PARAPET - OS CAP FLASHINGTERMINATION AT PARAPET -OS SOLID SUBSTRATETERMINATION AT SLOPED ROOFOS WALL/SUSPENDEDOS SOFFIT TRANSITIONTRANSITION AT SOFFIT/OS FASCIA INTERSECTIONFASCIA/UNINSULATED OS SOFFIT TRANSITIONTERMINATION AT UNINSULATEDOS SOFFIT VENTHORIZONTAL JOINT AT FLOOR LINEOS JOINT - OS SUBSTRATE CHANGEHORIZONTAL TERMINATION AT OS STONE VENEERHORIZONTAL TERMINATION AT OS TERMINATION AT OS WOOD SIDINGVERTICAL EXPANSION JOINT - EIFS OS EXPANSION JOINTOS EXPANSION JOINT - OS FLUSH AND RECESSED OPTION

nail-on window window head os 0.0.11 termination at os 0.0.12 wood framed deck ... cap flashing termination at parapet - os 0.0.16 solid substrate termination at sloped roof os 0.0.17 vertical wall/suspended os 0.0.18 soffit transition transition at soffit/ os 0.0.19 fascia intersection ... dryvit base coat eps insulation dryvit base coat ...

Tags:

  Base, Roof, Nail, Insulation, Outsulation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of OUTSULATION - Dryvit

1 DS107 OUTSULATION An Exterior Wall insulation and Finish System That Incorporates Continuous insulation OUTSULATION System Installation Details NOTEDETAIL TABLE OF CONTENTSDETAIL OUTSULATION SystemOUTSULATION SYSTEM OS PREPARATION- OS AQUAFLASH SYSTEM OPTIONINSIDE/OUTSIDE CORNERSOS CORNER - HIGH IMPACTOS TERMINATIONOS AT CONCRETE CURBOS AT OS ADA COMPLIANT SIDEWALKEPS PREPARATION ATOS WALL PENETRATIONSPREPARATION OF OPENING FOROS STOREFRONT WINDOWPREPARATION OF OPENING FOROS nail -ON WINDOWWINDOW HEAD OS AT OS WOOD FRAMED DECKTERMINATION AT OS WATERPROOF DECKPREPARATION AT PARAPET/OS WALL INTERSECTIONTERMINATION AT PARAPET - OS CAP FLASHINGTERMINATION AT PARAPET -OS SOLID SUBSTRATETERMINATION AT SLOPED ROOFOS WALL/SUSPENDEDOS SOFFIT TRANSITIONTRANSITION AT SOFFIT/OS FASCIA INTERSECTIONFASCIA/UNINSULATED OS SOFFIT TRANSITIONTERMINATION AT UNINSULATEDOS SOFFIT VENTHORIZONTAL JOINT AT FLOOR LINEOS JOINT - OS SUBSTRATE CHANGEHORIZONTAL TERMINATION AT OS STONE VENEERHORIZONTAL TERMINATION AT OS TERMINATION AT OS WOOD SIDINGVERTICAL EXPANSION JOINT - EIFS OS EXPANSION JOINTOS EXPANSION JOINT - OS FLUSH AND RECESSED OPTIONSVERTICAL EXPANSION JOINT -OS DOUBLE SEAL OPTIONVERTICAL TERMINATION OS AT STONE VENEERPENETRATIONSOS ATTACHMENTOS REVEALSOS GRAPHICSOS GRAPHICSOS Systems, Inc.

2 1969 Issued: 01/2015 Dryvit MAKES NO REPRESENTATION REGARDINGCONFORMITY OF ITS SUGGESTIONS TO MODEL BUILDINGCODES, ENGINEERING CRITERIA, SPECIFIC APPLICATIONS,OR PROJECT LOCATIONS. ALL COMPONENTS INDICATEDIN ILLUSTRATIONS, AS WELL AS OTHERS THAT MAY BEREQUIRED FOR THE INTEGRITY OF THE SYSTEM SHALL BEDESIGNED, DETAILED, AND ENGINEERED BYREPRESENTATIVES OF THE ARCHITECT, OWNER, ORCONTRACTOR TO BE IN CONFORMANCE WITH MODELCODES, ARCHITECTURAL, AND ENGINEERINGREQUIREMENTS PERTAINING TO SPECIFIC MAKES NO WARRANTY, EXPRESSED OR IMPLIED,AS TO THE ARCHITECTURAL DESIGN, ENGINEERING, ORWORKMANSHIP OF PROJECTS UTILIZING Dryvit SYSTEMSOR LIABILITIES OF Dryvit SHALL BE AS STATED IN THEOUTSULATION LIMITED COMMERCIAL Dryvit FOR A FULL AND COMPLETE COPY OFTHE architecture, engineering, and design of the project usingthe Dryvit products is the responsibility of the project's designprofessional.

3 All systems must comply with local building codesand standards. This detail is for general information andguidance only and Dryvit specifically disclaims any liability forthe use of this detail and for the architecture, design,engineering or workmanship of any project. The project designprofessional determines, in its sole discretion, whether thisdetail or a functionally equivalent detail is best suited for theproject. Use of a functionally equivalent detail does not violateDryvit's warranty. This detail is subject to change without Dryvit to ensure you have the most recent ADHESIVEO utsulation SystemOS Systems, Inc. 1969 OUTSULATION SystemNOTE:1. Dryvit RECOMMENDS THAT GROUNDFLOOR APPLICATIONS AND ALL FACADESEXPOSED TO ABNORMAL STRESS, HIGHTRAFFIC, OR DELIBERATE IMPACT HAVETHE base COAT REINFORCED WITHPANZER MESH PRIOR TO STANDARD OR STANDARD PLUS MESH.

4 LOCATIONOF HIGH IMPACT ZONES SHOULD BEINDICATED ON CONTRACT IMPACTHIGH IMPACTI ssued: 01/2015 EPS insulation BOARDAPPROVED SUBSTRATEDRYVIT base COATDRYVIT REINFORCING MESHEMBEDDED IN Dryvit base COATDRYVIT base COATDRYVIT FINISHFRAMINGDRYVIT ADHESIVEEPS insulation BOARDAPPROVED SUBSTRATEDRYVIT base COATDRYVIT REINFORCING MESHEMBEDDED IN Dryvit base COATDRYVIT base COATDRYVIT FINISHFRAMINGDRYVIT PANZER REINFORCING MESHDRYVIT base COATBY OTHERSOUTSULATION SYSTEMlThe architecture, engineering, and design of the project usingthe Dryvit products is the responsibility of the project's designprofessional. All systems must comply with local building codesand standards. This detail is for general information andguidance only and Dryvit specifically disclaims any liability forthe use of this detail and for the architecture, design,engineering or workmanship of any project.

5 The project designprofessional determines, in its sole discretion, whether thisdetail or a functionally equivalent detail is best suited for theproject. Use of a functionally equivalent detail does not violateDryvit's warranty. This detail is subject to change without Dryvit to ensure you have the most recent #1 STEP #2 STEP #4 STEP #3 Opening Preparation -AquaFlash System OptionOutsulation SystemOS :1. Dryvit AQUAFLASH SHALL EXTEND TOINTERIOR FACE OF REFER TO HEAD, SILL AND JAMB DETAILSFOR FLASHING Dryvit FLASHING TAPE SURFACECONDITIONER AND Dryvit FLASHINGTAPE MAY BE USED IN LIEU OF DRYVITAQUAFLASH INSTALL WINDOW UNIT AND ASSOCIATEDFLASHINGS PER MANUFACTURER'SRECOMMENDATIONS, CODE REQUIREMENTS ANDPROJECT AQUAFLASH SYSTEM CONSISTS OF AQUAFLASHMESH AND AQUAFLASH Systems, Inc. 1969 Issued: 01/2015 INSTALL DIAGONAL STRIP OF DRYVITAQUAFLASH MESH AT CORNERSAND EMBED IN AQUAFLASH LIQUID(SEE NOTES 1, 3)APPLY Dryvit AQUAFLASH SYSTEM (SEE NOTES 1 AND 3)INSTALL Dryvit AQUAFLASHSYSTEM AT HEADS(SEE NOTES 1, 3 AND 4)INSTALL Dryvit AQUAFLASHSYSTEM AT JAMBS(SEE NOTES 1 AND 3)lThe architecture, engineering, and design of the project usingthe Dryvit products is the responsibility of the project's designprofessional.

6 All systems must comply with local building codesand standards. This detail is for general information andguidance only and Dryvit specifically disclaims any liability forthe use of this detail and for the architecture, design,engineering or workmanship of any project. The project designprofessional determines, in its sole discretion, whether thisdetail or a functionally equivalent detail is best suited for theproject. Use of a functionally equivalent detail does not violateDryvit's warranty. This detail is subject to change without Dryvit to ensure you have the most recent version. OS CornersOutsulation System8" (203 MM) OVERLAP8" (203 MM) NOTE 3 MUST OVERLAP 8" (203 MM) MIN.(SEE NOTES 2, 3 AND 4)8"(203 MM) Systems, Inc. 1969 Dryvit FINISH Issued: 01/2015 NOTE:1. Dryvit RECOMMENDS THAT GROUNDFLOOR APPLICATIONS AND ALL FACADESEXPOSED TO ABNORMAL STRESS, HIGHTRAFFIC, OR DELIBERATE IMPACT HAVE THEBASE COAT REINFORCED WITH PANZER MESH PRIOR TO STANDARD OR STANDARDPLUS MESH.

7 LOCATION OF HIGH IMPACTZONES SHOULD BE INDICATED ONCONTRACT DOUBLE WRAP OUTSIDE CORNERS WITHREINFORCING MESH OR USE CORNER DO NOT LAP REINFORCING MESH WITHIN8" (203 MM) OF A OUTSIDE insulation BOARD EDGESSHALL BE SUBSTRATEDRYVIT base COATDRYVIT REINFORCING MESHEMBEDDED IN Dryvit base COATDRYVIT ADHESIVEEPS INSULATIONDRYVIT FINISHDRYVIT base COATDRYVIT base COATDRYVIT REINFORCING MESHEMBEDDED IN Dryvit base COATEPS INSULATIONAPPROVED SUBSTRATEDRYVIT ADHESIVEDRYVIT base COATBY OTHERSOUTSULATION SYSTEMlThe architecture, engineering, and design of the project usingthe Dryvit products is the responsibility of the project's designprofessional. All systems must comply with local building codesand standards. This detail is for general information andguidance only and Dryvit specifically disclaims any liability forthe use of this detail and for the architecture, design,engineering or workmanship of any project.

8 The project designprofessional determines, in its sole discretion, whether thisdetail or a functionally equivalent detail is best suited for theproject. Use of a functionally equivalent detail does not violateDryvit's warranty. This detail is subject to change without Dryvit to ensure you have the most recent version. OS Corner - High ImpactOutsulation SystemDryvit Systems, Inc. 1969 Issued: 01/2015 NOTE:1. Dryvit RECOMMENDS THAT GROUNDFLOOR APPLICATIONS AND ALL FACADESEXPOSED TO ABNORMAL STRESS, HIGHTRAFFIC, OR DELIBERATE IMPACT HAVETHE base COAT REINFORCED WITHPANZER MESH PRIOR TO STANDARD OR STANDARD PLUS MESH. LOCATIONOF HIGH IMPACT ZONES SHOULD BEINDICATED ON CONTRACT OUTSIDE insulation BOARD EDGESSHALL BE OTHERSOUTSULATION SYSTEMlThe architecture, engineering, and design of the project usingthe Dryvit products is the responsibility of the project's designprofessional.

9 All systems must comply with local building codesand standards. This detail is for general information andguidance only and Dryvit specifically disclaims any liability forthe use of this detail and for the architecture, design,engineering or workmanship of any project. The project designprofessional determines, in its sole discretion, whether thisdetail or a functionally equivalent detail is best suited for theproject. Use of a functionally equivalent detail does not violateDryvit's warranty. This detail is subject to change without Dryvit to ensure you have the most recent version. 8"(203 MM) FINISHDRYVIT ADHESIVEAPPROVED SUBSTRATEDRYVIT base COATDRYVIT PANZER REINFORCING MESHDRYVIT STANDARD MESH ORSTANDARD PLUS REINFORCINGMESH OVERLAP MIN. 8" (203 MM)AT CORNEREPS INSULATIONDRYVIT CORNER MESH 8"(203 MM) base COATDRYVIT base COATO utsulation SystemGrade TerminationOS :1.

10 Dryvit RECOMMENDS THAT GROUNDFLOOR APPLICATIONS AND ALL FACADESEXPOSED TO ABNORMAL STRESS, HIGHTRAFFIC, OR DELIBERATE IMPACT HAVETHE base COAT REINFORCED WITHPANZER MESH PRIOR TO STANDARD OR STANDARD PLUS MESH. LOCATIONOF HIGH IMPACT ZONES SHOULD BEINDICATED ON CONTRACT EXPANSION JOINT IS REQUIRED ALONGTOP OF FOUNDATION IF 2'-0" (610 MM)DIMENSION IS SLOPE GRADE AWAY FROM STOP FINISH APPROXIMATELY 2" (51 MM)BELOW GRADE AWAYFROM FOUNDATION WALL2'-0"(610 MM) MAX.(SEE NOTE 2) Dryvit DETAIL MESH WRAPPEDTO BACKSIDE OF EPS MIN. 2" (51 MM)EPS INSULATIONDRYVIT FINISHDRYVIT base COATDRYVIT REINFORCING MESHEMBEDDED IN Dryvit base COATDRYVIT ADHESIVEAPPROVED SUBSTRATEDRYVIT base COATDRYVIT DRYFLEX WATERRESISTANT base COATDRYVIT FINISHD ryvit Systems, Inc. 1969 Issued: 01/2015 Dryvit COMPATIBLE SEALANT WITHBOND BREAKER, BY OTHERS8" (203 MM) MIN.