Example: bankruptcy

DRO 200T - ACU-RITE

dro 200t REFERENCE MANUALR eadout Parameter Access CodeAn access code must be entered before machine-related parameters can be set orchanged. This prevents inadvertent adjustments to the setup access code is 8891 Refer to the Setup section. Begin by pressing the SETUP key. When SETUP isdisplayed, press the 8, 8, 9, 1, and ENTER keys. The readout is nowready for machine parameter setting may wish to remove this page from the Reference manualafter initially setting up the readout system. Retain in a safe placefor future Products and accessories are warranted against defectsin material and workmanship for a period of three years from thedate of purchase.

Warranty ACU-RITE Products and accessories are warranted against defects in material and workmanship for a period of three years from the date of purchase.

Tags:

  Tier, T200, Dro 200t

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of DRO 200T - ACU-RITE

1 dro 200t REFERENCE MANUALR eadout Parameter Access CodeAn access code must be entered before machine-related parameters can be set orchanged. This prevents inadvertent adjustments to the setup access code is 8891 Refer to the Setup section. Begin by pressing the SETUP key. When SETUP isdisplayed, press the 8, 8, 9, 1, and ENTER keys. The readout is nowready for machine parameter setting may wish to remove this page from the Reference manualafter initially setting up the readout system. Retain in a safe placefor future Products and accessories are warranted against defectsin material and workmanship for a period of three years from thedate of purchase.

2 ACU-RITE will, at its option and expense, repairor replace any part of the ACU-RITE product that fails to meet thiswarranty. This warranty covers both materials and factory labor. Inaddition, authorized ACU-RITE service representatives will provideservice labor (field service) for a period of one year at no of the claimed defect must be received by ACU-RITE withinthe warranty warranty applies only to products and accessories installedand operated in accordance with this reference manual.

3 ACU-RITE shall have no obligation, with respect to any defect or othercondition caused in whole or part by the customer s incorrect use,improper maintenance, modification of the equipment, or by therepair or maintenance of the product by any person except thosedeemed qualified by for loss of operation or diminished performance dueto conditions beyond ACU-RITE s control cannot be accepted foregoing warranty obligations are in lieu of all expressed orimplied warranties.

4 ACU-RITE INCORPORATED shall not be liableunder any circumstances for consequential Day Red Carpet WarrantyAll ACU-RITE products are covered by a 30-day Red CarpetWarranty. If in the first 30 days this product fails for any reason,repack it in the original packing materials and contact yourAuthorized ACU-RITE Distributor for return 200 TTable of Tour of the and Back Position and Incremental the and Incremental Zero Tools with the Auto-Offset Calculation Tools with a Tool Setup Setup Zero Offset Error 200T!

5 This symbol alerts you to the fact thatimportant information concerning theinstallation and operation of this readouthas been included in this these instructions in a secure placefor future 200 TIntroduction1 IntroductionACU-RITE s DRO 200 readout series provides application-specific featuresrequired for you to obtain the most productivity from your manual machine dro 200t is designed specifically for turning applications. Special featuresinclude radius/diameter conversion, a tool offset library, and an axis lock Tour of the ReadoutFront and Back Views3x DROPN 2001009SN 9766554 FCC COMPLIANCE115 VEDGEFINDERINPUT 1 INPUT 2 INPUT 3!

6 FREQUENCYVOLTAGECURRENTFUSEE ncoderinputsModel numberandSerial numberElectrical &fuse ratinginformationPower switch andvoltage selectorGround +/-3 LOCKAXISDEFINEUSETOOLOFFSETSI ndicatorsApplication-specificfunction keysIntroductionDRO +/-3 DEFINEUSETOOLOFFSETSZEROZEROZEROZ2Z1 XSelects absolute orincremental displaySelects radius ordiameter displayLocks the display so youcan move the tool withoutlosing positionEnglish / metricconversionSystem setupparametersEnter all numeric valueswith theseLets you define a library oftool offsets, and selectwhich offset to useBegin a presetZero an axis displayDRO 200 TIntroduction3 Lets you know whenyou are setting apreset or an the top of the display window is a row of indicators.

7 These tell you the currentstate of the addition to the lighted indicators along the top of the display, the top axisdisplay will scroll longer messages that will help you step through some of when you repositioning in metric,dark when you repositioning in inches. These tell you if theposition display isincremental or also refer to thetype of you when thecrossfeed axis isdisplaying the part whensetting anabsolute 200T4 Power-On Position RecoveryPosition-TracCertain ACU-RITE encoders, such as the ENC 150, contain closely-spacedreference marks that enable the display to show the correct position after a powerinterruption.

8 The readout will indicate when power has been lost, and will promptyou to move each axis until a reference mark is located. By traversing thereference marks once in each axis, you will re-establish the display positionrelative to the last known zero. The most you will ever have to move an axis isabout one inch. You must move in a positive count direction. A flashing decimalpoint will indicate that the last position has not been you use an encoder that does not have the Position-Trac feature, the procedurefor recovering your position is slightly different.

9 Reference marks on theseencoders are about 8 apart. You must find a convenient reference mark and thenuse the same mark every Move near the desired reference Press and hold the ABSINCR key until the decimal point starts to Move slowly past the reference mark until the readout recalls itsposition. You must move in a positive 200 TReadout Operations5 Readout OperationsClear KeyUse the CLEAR key to erase digits that you entered by mistake, or to take you back ifyou ve pressed a wrong function and Incremental DisplaysAbsolute DisplayShows the distance from your current position to absolute DisplayShows the distance from your current position to incremental zero.

10 An incrementalzero is set when you preset a dimension, or when you zero the zero:the incrementaldisplay will when thetool is zeroZ INCRABSINCRZ Zero,also called datumor ABSThe tool is positioined at OperationsDRO 200T6 Automatic Display SwitchingSometimes the readout will switch from one display to another you enter a preset, for example, the display switches to the incrementaldisplay so you can move to zero. Whenever the readout does an automatic displayswitch, INCR will appear in the DisplayPressing the RADDIA key lets you view a workpiece dimension either as a radius oras a 200 TReadout Operations7 Zeroing the DisplaysAbsolute ZeroOn many prints, the dimensions are measured fromone or two surfaces of the part.